LIVE FEED
A proposed class action accuses University Hospitals of negligence after an October 22 cyberattack that took its MyChart portal offline; the Cleveland patient's suit, filed October 28, claims more than a million records were exposed, a number University Hospitals has not confirmed. University of New Mexico Health Sciences Center disclosed a cyberattack October 26 that diverted ambulances for about two hours; the BYOD extortion group claims it compromised 36,000 systems, a figure UNM has not confirmed. Philips updated its Node2Shell advisory October 27 for CVE-2026-111497, the Node.js Brotli decoder flaw it first flagged October 26 against PIC iX 4.x; the advisory still names no impacted products or fixed version. Philips updated its PHP2Shell advisory October 27 for CVE-2026-109618 and CVE-2026-109619, adding five more affected products including IntelliSpace Portal V12 and Philips Axon to the seven already listed. NorthShore Health Centers disclosed a data breach to patients October 27, one of several Midwest provider notifications issued that week. Denver Health Medical Plan notified more than 238,000 members October 26 about a vendor-related data incident. A proposed class action accuses University Hospitals of negligence after an October 22 cyberattack that took its MyChart portal offline; the Cleveland patient's suit, filed October 28, claims more than a million records were exposed, a number University Hospitals has not confirmed. University of New Mexico Health Sciences Center disclosed a cyberattack October 26 that diverted ambulances for about two hours; the BYOD extortion group claims it compromised 36,000 systems, a figure UNM has not confirmed. Philips updated its Node2Shell advisory October 27 for CVE-2026-111497, the Node.js Brotli decoder flaw it first flagged October 26 against PIC iX 4.x; the advisory still names no impacted products or fixed version. Philips updated its PHP2Shell advisory October 27 for CVE-2026-109618 and CVE-2026-109619, adding five more affected products including IntelliSpace Portal V12 and Philips Axon to the seven already listed. NorthShore Health Centers disclosed a data breach to patients October 27, one of several Midwest provider notifications issued that week. Denver Health Medical Plan notified more than 238,000 members October 26 about a vendor-related data incident.
Saturday, October 31, 2026 Issue #499  ·  Est. 2025
Independent brief for device makers
Manufacturers // Baxter

Baxter

Baxter in MedDevice Cyber coverage: 30 stories, 38 products named, 41 CVEs, and the company's own disclosures.

Public disclosure program
Stories
30
Products named
38
Product CVEs
41
Responses on record
0
Latest story
Aug 14, 2026

Coverage

30 stories
01
Intelligence

ShinyHunters lists Baxter, claims 7.1 million Salesforce records

ShinyHunters listed Baxter International on its extortion site on August 14, claiming more than 7.1 million Salesforce records, one day after Baxter disclosed unauthorized activity involving third-party applications. Baxter says manufacturing, patient services, and its products are unaffected and has not confirmed any data theft.

BaxterAug 143 min read
02
Vulnerability

Baxter Starling fluid monitor runs unsupported Windows Embedded Compact 7

Baxter's Starling-2026-001 bulletin, published in June 2026, says a security assessment of the Starling Fluid Management Monitoring System found potential vulnerabilities, including the unsupported Windows Embedded Compact 7 operating system.

BaxterJun 13 min read
03
Vulnerability

Compounding software that did not encrypt its database traffic by default

A Baxter bulletin flagged that Abacus supports encrypted client-server communication but did not enable transport encryption by default in legacy configurations, leaving SQL traffic open to interception.

Baxter Product SecurityMay 152 min read
04
Vulnerability

Baxter Abacus 3.3.5 and earlier leave client to SQL server encryption off by default

Baxter bulletin Abacus-2026-001 says ABACUS Software lets the client to SQL server link run without encryption, which is not enabled by default in versions 3.3.5 and prior.

BaxterMar 12 min read
05
Vulnerability

Baxter DoseEdge server can reach peripherals over HTTP, exposing compounding orders in cleartext

Baxter bulletin DoseEdge-2026-001 says the DoseEdge Pharmacy Workflow Manager local server, all versions, allows HTTP instead of HTTPS to peripheral devices, which could expose compounding order data in plaintext.

BaxterMar 12 min read
06
Vulnerability

Baxter warns of a Newmar radio PIM file flaw in Connex vital signs monitors

Baxter bulletin 80031885 Rev. A says a flaw in how Connex CVSM, CIWS and CSM devices with the Newmar radio handle PIM files could expose network information, reconfigure the radio and cut clinical data connectivity; a fix is in development.

BaxterFeb 183 min read
07
Vulnerability

Two maximum-severity flaws in a ventilation system

ICSMA-24-319-01: Baxter Life2000 Ventilation System carried nine CVEs, two rated a maximum 10.0, spanning hard-coded credentials, cleartext transmission, an exposed JTAG interface and missing authentication.

CISANov 143 min read
08
Vulnerability

A 10.0 SQL injection on a patient health portal

ICSMA-24-249-01: the Baxter Connex Health Portal had a critical unauthenticated SQL injection, base score 10.0, letting a remote attacker run arbitrary SQL, plus an access-control flaw exposing patient and clinician data.

CISASep 52 min read
09
Vulnerability

Baxter Welch Allyn Configuration Tool put entered credentials at risk

CISA advisory ICSMA-24-151-01 covers CVE-2024-5176 (CWE-522, CVSS 9.6) in the Baxter Welch Allyn Product Configuration Tool 1.9.4.1 and prior: any credentials used in the tool may be compromised. Baxter pulled the tool and planned 1.9.4.2 for Q3 2024.

CISAMay 302 min read
10
Vulnerability

Baxter Welch Allyn Connex Spot Monitor used a default cryptographic key

CISA advisory ICSMA-24-151-02 covers CVE-2024-1275 (CWE-1394, CVSS 7.4), a default cryptographic key in the Baxter Welch Allyn Connex Spot Monitor 1.52 and prior that could allow changes to device configuration and firmware data. Version 1.52.01 fixes it.

CISAMay 302 min read
11
Vulnerability

Baxter finds no product exposure to ConnectWise ScreenConnect flaws CVE-2024-1709 and CVE-2024-1708

Baxter said on February 26, 2024 that it found no indication its products are affected by CVE-2024-1709 and CVE-2024-1708 in ConnectWise ScreenConnect 23.9.7 and prior, and no privacy impact.

BaxterFeb 262 min read
12
Vulnerability

Baxter lists five Hillrom, Welch Allyn and connectivity products exposed to Mirth Connect CVE-2023-43208

Baxter's January 31, 2024 bulletin lists Hillrom Smart Device Connectivity, Welch Allyn RetinaVue Network, ELI Link (HL7 configuration), Voalte Nurse Call and Sharesource Connect as possibly affected by critical Mirth Connect flaw CVE-2023-43208.

BaxterJan 313 min read
13
Vulnerability

Baxter Sigma Spectrum wireless battery modules keep Wi-Fi credentials unencrypted and skip server authentication

CISA advisory ICSMA-22-251-01 covers four flaws in Baxter Sigma Spectrum and Spectrum IQ infusion pump Wireless Battery Modules, including unencrypted stored network credentials and PHI (CVE-2022-26390) and missing mutual authentication with the gateway server (CVE-2022-26394, CVSS 7.5). Deral Heiland of Rapid 7 reported them.

CISASep 84 min read
14
Vulnerability

Hillrom Welch Allyn ELI resting electrocardiographs contain hard-coded passwords

CISA advisory ICSMA-22-167-01 covers CVE-2022-26388 (hard-coded password, CVSS v3 6.4) and CVE-2022-26389 (improper access control, CVSS v3 7.7) in Welch Allyn ELI 150c, 250c, 280 and 380 resting electrocardiographs. Hillrom has released software updates for all of them.

CISAJun 162 min read
15
Vulnerability

Baxter says Amia and Kaguya use Axeda agents named in PTC's Access:7 advisory

Baxter's March 22, 2022 bulletin states that all fielded versions of Amia and Kaguya use Axeda agents listed in PTC's Access:7 advisory, and that it is working with PTC to upgrade the agent during 2022.

BaxterMar 222 min read
16
Vulnerability

Baxter says every product is unaffected, patched or mitigated for Log4j

Baxter's Log4j bulletin of December 13, 2021, updated December 28, 2021, says all Baxter products are either not impacted, patched, or mitigations have been applied for the critical Apache Log4j vulnerabilities.

BaxterDec 132 min read
17
Vulnerability

Hillrom Welch Allyn cardiology software let SSO users log in as any AD account without a password

CISA advisory ICSMA-21-343-01 covers CVE-2021-43935 (CWE-288, CVSS 8.1) in seven Hillrom Welch Allyn cardiology products, including Q-Stress, X-Scribe and R-Scribe, which accepted any provisioned Active Directory account without a password when SSO was configured.

CISADec 92 min read
18
Vulnerability

Baxter says every ExactaMix compounder version is exposed to PrintNightmare

Baxter's July 23, 2021 bulletin on CERT/CC VU#383432 says all ExactaMix 1200 and 2400 versions contain Windows and are impacted by CVE-2021-34527, the PrintNightmare Print Spooler remote code execution flaw.

BaxterJul 232 min read
19
Vulnerability

Hillrom Welch Allyn Connex and Spot devices carry chained out-of-bounds write and read flaws

CISA advisory ICSMA-21-152-01 covers an out-of-bounds write (CVE-2021-27410) and out-of-bounds read (CVE-2021-27408), both CVSS 5.9, across Hillrom Welch Allyn Connex monitors, Spot 4400, the Network Connectivity Engine, the SDK and service tools. Chained, they can lead to code execution. Fixed versions are listed per product.

CISAJun 13 min read
20
Vulnerability

Baxter PrisMax 2.1 carries three Ripple20 flaws through its modified Treck stack

Baxter says PrisMax software 2.1, when connected to an EMR/PDMS via Ethernet, uses GHnet v2, a modified Treck TCP/IP stack, and is affected by CVE-2020-11907, CVE-2020-11911 and CVE-2020-11914, with impact limited to network connectivity.

BaxterJul 302 min read
21
Vulnerability

Baxter ExactaMix compounders carry hard-coded admin credentials and send orders in clear text

CISA advisory ICSMA-20-170-01 covers seven flaws in Baxter ExactaMix EM1200 and EM2400 compounders, led by hard-coded OS admin credentials (CVE-2020-12016, CVSS 8.1), cleartext order traffic and an unencrypted database. Baxter recommends upgrading to EM1200 1.4 and EM2400 1.13 plus compensating controls.

CISAJun 184 min read
22
Vulnerability

Baxter Phoenix hemodialysis system sends treatment and prescription data in cleartext

CISA advisory ICSMA-20-170-03 covers CVE-2020-12048 (CWE-319, CVSS v3 7.5) in the Baxter Phoenix Hemodialysis Delivery System versions 3.36 and 3.40, which does not encrypt data sent to the Exalis data management tool. Baxter issued implementation guidance.

CISAJun 182 min read
23
Vulnerability

Baxter PrismaFlex and PrisMax send treatment data to EMR systems without encryption or authentication

CISA advisory ICSMA-20-170-02 covers missing authentication (CVE-2020-12035, CVSS v3 7.6), cleartext transmission (CVE-2020-12036, CVSS v3 6.5) and a hard-coded service password (CVE-2020-12037) in Baxter PrismaFlex and PrisMax. PrisMax v3 with the Digital Communication Module adds a mutually authenticated TLS tunnel.

CISAJun 183 min read
24
Vulnerability

Baxter Sigma Spectrum infusion pumps and wireless battery modules carry hard-coded passwords

CISA advisory ICSMA-20-170-04 (Update B) covers six flaws in Baxter Sigma Spectrum and Spectrum infusion systems and their Wireless Battery Modules, including a hard-coded Telnet login (CVE-2020-12045, CVSS 8.6) and cleartext pump communications (CVE-2020-12040). Baxter lists network and physical controls.

CISAJun 184 min read
25
Vulnerability

Baxter Spectrum Wireless Battery Module carries the Ripple20 flaws in Digi Net+OS

Baxter says all versions of the Spectrum Wireless Battery Module use the Treck TCP/IP stack in Digi Net+OS and contain the Ripple20 vulnerabilities, CVE-2020-11896 to CVE-2020-11914; an October 2024 update adds the latest Digi patch for CVE-2020-11901.

BaxterJun 163 min read
26
Vulnerability

Baxter finds ExactaMix v1.4, v1.5, v1.13 and v1.14 susceptible to Remote Desktop Client flaw CVE-2020-0611

Baxter evaluated its products against CISA alert AA20-014A and found ExactaMix v1.4/v1.5 (EM1200) and v1.13/v1.14 (EM2400) susceptible to CVE-2020-0611, a Remote Desktop Client remote code execution vulnerability.

BaxterMar 172 min read
27
Vulnerability

Baxter says no products use a Bluetooth version affected by SweynTooth

Baxter's March 9, 2020 bulletin says no Baxter products use an impacted version of Bluetooth for the SweynTooth BLE vulnerabilities covered in CISA's ICS-ALERT-20-063-01.

BaxterMar 92 min read
28
Vulnerability

Baxter ExactaMix compounders run Windows builds exposed to the MS17-010 SMBv1 flaws

Baxter says ExactaMix EM1200 v1.1 and v1.2 and EM2400 v1.10 and v1.11 run Windows builds affected by the MS17-010 SMBv1 remote code execution vulnerabilities. ExactaMix v1.4 (EM1200) and v1.13 (EM2400) move to Windows 10 with SMBv1 disabled.

BaxterDec 112 min read
29
Vulnerability

Baxter finds no products using the IPnet TCP/IP stack behind Urgent/11

Baxter's September 24, 2019 bulletin on Urgent/11 (CVE-2019-12255 through CVE-2019-12265) says no Baxter products use the Interpeak IPnet TCP/IP stack or an impacted version of an RTOS.

BaxterSep 242 min read
30
Vulnerability

Baxter flags ExactaMix EM2400 v1.10/v1.11 and EM1200 v1.1/1.2 for BlueKeep RDP flaw

Baxter's May 16, 2019 bulletin lists ExactaMix (EM2400) v1.10/v1.11 and ExactaMix (EM1200) v1.1/1.2 as running an operating system susceptible to CVE-2019-0708 and recommends upgrading to EM1200 v1.4 and EM2400 v1.13 on Windows 10.

BaxterMay 163 min read

Products in our coverage

Products and threat intel

15

Baxter products with the device attributes their own public documentation states, and the advisories in our coverage that share those attributes.

ProductDevice typeAttributesMatched advisories
WAVE Clinical PlatformMonitor, Physiological, Patient (Without Arrhythmia Detection Or Alarms)2432
Dose IQ Safety SoftwareInfusion Safety Management Software2331
Novum IQ Large Volume PumpPump, Infusion1812
Welch Allyn Connex Spot Monitor; 901058 Vital Signs Monitor CoreMonitor, Physiological, Patient (Without Arrhythmia Detection Or Alarms)208
Homechoice Claria APD SystemSystem, Peritoneal, Automatic Delivery127
Spectrum IQ Infusion System with Dose IQ Safety SoftwarePump, Infusion243
Baxter SIGMA Spectrum Infusion Pump with Master Drug LibraryPump, Infusion81
Hillrom Heart and Respiration Rate Monitoring System powered byMonitor, Breathing Frequency201
iExaminer System with Panoptic PlusCamera, Ophthalmic, Ac-Powered20
Intravascular Administration SetsSet, Administration, Intravascular40
Intravascular Extension SetSet, Administration, Intravascular30
Maximus SystemDevice, Positive Pressure Breathing, Intermittent70
Novum IQ Syringe PumpPump, Infusion200
SIGMA Spectrum Infusion Pump with Master Drug LibraryPump, Infusion70
The Vest APX SystemPercussor, Powered-Electric100

CVEs in coverage of Baxter products