Vscan Air
System, Imaging, Pulsed Doppler, Ultrasonic. Attributes come from GE HealthCare's own public documentation for this product.
Attributes
Signals
Properties (MITRE EMB3D)
PID-23 Device includes OS/kernel PID-2322 Device deploys an access enforcement/privilege mechanism PID-27 Device includes support for firmware/software updates PID-31 Application-level software is present and running on the device PID-311 Device includes the usage of a web/HTTP applications PID-33 Device includes interactive applications, services, or user interfaces PID-332 Device includes authenticated services PID-41 Device exposes remote network services PID-411 Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations PID-4113 Device includes cryptographic functions for sensitive data, such as encryption or authentication
Platform
Android iOS
Attributes: component types
API Battery Display Firmware Generic Application Generic Hardware Library Local Application Local Service Mobile Application Operating System Sensor Modules User Interface Web Application Wireless Module
Attributes: interface types
Wireless
Attributes: assets
Credentials Firmware Patient Data Sensor Data Software Configuration
Attributes: dataflows
Probe to Mobile Device (Android/iOS app) wirelessly, ultrasound images Probe to Vscan Air app over wireless Vscan Air app to 3rd party apps, auto-anonymized data Vscan Air app to PACS (DICOM storage commit)
Matched threat intel
53
Advisories in our coverage that share an attribute with this product. A shared attribute is a lead, not a finding. The status column shows only what GE HealthCare has said.
| Advisory | Date | Shared | GE HealthCare status |
|---|---|---|---|
| Path traversal in Thermo Fisher's Torrent Suite lets authenticated users read server files | Oct 15, 2026 | Same property (MITRE EMB3D)PID-332 | No feedback feed from manufacturer |
| Mira’s cloud login accepted any password and returned a session token | Aug 11, 2026 | Same property (MITRE EMB3D)PID-411 | No feedback feed from manufacturer |
| A hard-coded VNC password on a bioreactor, base score 9.8 | May 26, 2026 | Same property (MITRE EMB3D)PID-332 | No feedback feed from manufacturer |
| Compounding software that did not encrypt its database traffic by default | May 15, 2026 | Same property (MITRE EMB3D)PID-4113 | No feedback feed from manufacturer |
| Login credentials exposed on the workstation in a GE imaging viewer | Mar 16, 2026 | Same property (MITRE EMB3D)PID-332 | No feedback feed from manufacturer |
| EMS patient-care app reflects unsanitized input into a WebView | Feb 10, 2026 | Same property (MITRE EMB3D)PID-311 | No feedback feed from manufacturer |
| User enumeration on the CareLink Network, found at a conference | Dec 4, 2025 | Same property (MITRE EMB3D)PID-332 | No feedback feed from manufacturer |
| A hospital management backend leaked its own system information | Oct 28, 2025 | Same property (MITRE EMB3D)PID-311 | No feedback feed from manufacturer |
| Missing authentication on a DNA sequencer control plane | Oct 21, 2025 | Same property (MITRE EMB3D)PID-332 | No feedback feed from manufacturer |
| A low-privilege user can walk past role limits in Synapse Mobility | Aug 21, 2025 | Same property (MITRE EMB3D)PID-2322 | No feedback feed from manufacturer |
| Five flaws in Sante PACS Server, and one sends credentials in cleartext | Aug 12, 2025 | Same property (MITRE EMB3D)PID-311 | No feedback feed from manufacturer |
| Pixmeo OsiriX MD crashes on crafted DICOM files and sends web portal credentials in cleartext | May 8, 2025 | Same property (MITRE EMB3D)PID-311 | No feedback feed from manufacturer |
| Dario Health glucose monitoring app and servers exposed cross-user health data | Feb 27, 2025 | Same property (MITRE EMB3D)PID-311 | No feedback feed from manufacturer |
| Thermo Fisher Xcalibur and Foundation driver packages allow local privilege escalation | Jan 22, 2025 | Same property (MITRE EMB3D)PID-23 | No feedback feed from manufacturer |
| A 10.0 SQL injection on a patient health portal | Sep 5, 2024 | Same property (MITRE EMB3D)PID-311 | No feedback feed from manufacturer |
| Baxter Welch Allyn Connex Spot Monitor used a default cryptographic key | May 30, 2024 | Same property (MITRE EMB3D)PID-4113 | No feedback feed from manufacturer |
| Fresenius lists Conox anesthesia monitor as affected by BLUFFS Bluetooth flaw | Apr 10, 2024 | Same property (MITRE EMB3D)PID-4113 | No feedback feed from manufacturer |
| BD Synapsys sessions did not expire, risking changes to patient data | May 31, 2022 | Same property (MITRE EMB3D)PID-332 | No feedback feed from manufacturer |
| LifePoint Informatics Patient Portal generated lab report PDFs from a URL and a patient ID | Apr 5, 2022 | Same property (MITRE EMB3D)PID-311 | No feedback feed from manufacturer |
| Philips PIC iX and Efficia CM Series carry a hard-coded key and weak crypto | Nov 18, 2021 | Same property (MITRE EMB3D)PID-4113 | No feedback feed from manufacturer |
| Philips Tasy EMR HTML5 has two SQL injection flaws that expose patient data | Nov 4, 2021 | Same property (MITRE EMB3D)PID-332 | No feedback feed from manufacturer |
| Innokas VC150 vital signs monitor accepts HL7 injection and stored XSS | Jan 7, 2021 | Same property (MITRE EMB3D)PID-311 | No feedback feed from manufacturer |
| Philips Clinical Collaboration Platform 12.2.1 and earlier has five web and authentication flaws | Sep 17, 2020 | Same property (MITRE EMB3D)PID-311 | No feedback feed from manufacturer |
| Philips IntelliVue monitors and PIC iX skip certificate revocation and crash on bad input | Sep 10, 2020 | Same property (MITRE EMB3D)PID-4113 | No feedback feed from manufacturer |
| BIOTRONIK CardioMessenger II-S home monitors store recoverable credentials and leak them in cleartext | Jun 18, 2020 | Same property (MITRE EMB3D)PID-4113 | No feedback feed from manufacturer |
| Philips IntelliBridge EC40 and EC80 hubs allow weak SSH ciphers | Nov 14, 2019 | Same property (MITRE EMB3D)PID-4113 | No feedback feed from manufacturer |
| Philips Tasy EMR and WebPortal carry cross-site scripting and information exposure flaws | Apr 30, 2019 | Same property (MITRE EMB3D)PID-311 | No feedback feed from manufacturer |
| Philips HealthSuite Health Android app uses encryption too weak for its data | Dec 6, 2018 | Same property (MITRE EMB3D)PID-4113 | No feedback feed from manufacturer |
| Change Healthcare PeerVue Web Server leaks technical details in HTTP error messages | Oct 4, 2018 | Same property (MITRE EMB3D)PID-311 | No feedback feed from manufacturer |
| Medtronic MyCareLink 24950 and 24952 monitors store upload credentials in a recoverable format | Aug 7, 2018 | Same property (MITRE EMB3D)PID-4113 | No feedback feed from manufacturer |
| BeaconMedaes TotalAlert Scroll Medical Air Systems expose stored passwords to unauthenticated users | May 24, 2018 | Same property (MITRE EMB3D)PID-311 | No feedback feed from manufacturer |
| Philips EncoreAnywhere exposes sensitive data in its HTTP headers | May 17, 2018 | Same property (MITRE EMB3D)PID-311 | No feedback feed from manufacturer |
| B. Braun SpaceStation with SpaceCom module has an open redirect in its web server | Mar 23, 2017 | Same property (MITRE EMB3D)PID-311 | No feedback feed from manufacturer |
| BPL PWS-01-BT weighing scale sends unencrypted, unauthenticated BLE data to the Be Well app | Sep 10, 2024 | Same platformAndroid | No feedback feed from manufacturer |
| Medtronic MyCareLink Smart 25000 reader allows Bluetooth authentication bypass and unsigned firmware | Dec 10, 2020 | Same platformAndroid 6.0 | No feedback feed from manufacturer |
| Apollo Pharmacy APG-01 BT glucose meter sends readings over BLE in cleartext | Jun 18, 2026 | Exposed to the same EMB3D threatTID-411 | No feedback feed from manufacturer |
| Hard-coded credentials and client-side auth in nuclear-medicine software | Dec 2, 2025 | Exposed to the same EMB3D threatTID-329 | No feedback feed from manufacturer |
| Ossur Logic mobile app shipped hard-coded credentials and a static token in its binary | Dec 19, 2024 | Exposed to the same EMB3D threatTID-329 | No feedback feed from manufacturer |
| Default credentials across a line of diagnostic instruments | Dec 17, 2024 | Exposed to the same EMB3D threatTID-329 | No feedback feed from manufacturer |
| Unauthenticated SQL injection into an imaging database, base score 9.8 | Dec 6, 2024 | Exposed to the same EMB3D threatTID-320 | No feedback feed from manufacturer |
| Philips Vue PACS before 12.2.8.410 ships a default database password and can be overloaded | Jul 18, 2024 | Exposed to the same EMB3D threatTID-329 | No feedback feed from manufacturer |
| Softneta MedDream PACS allows unauthenticated remote code execution | Sep 5, 2023 | Exposed to the same EMB3D threatTID-329 | No feedback feed from manufacturer |
| BD Viper LT system uses hard-coded credentials that expose patient data | Mar 3, 2022 | Exposed to the same EMB3D threatTID-329 | No feedback feed from manufacturer |
| BD Pyxis dispensing and supply systems ship with hard-coded credentials across 24 products | Mar 3, 2022 | Exposed to the same EMB3D threatTID-329 | No feedback feed from manufacturer |
| Philips DreamMapper 2.24 and earlier write attacker-useful details to log files | Jul 30, 2020 | Exposed to the same EMB3D threatTID-311 | No feedback feed from manufacturer |
| OpenClinic GA advisory lists authentication bypass, file upload and SQL abuse flaws | Jul 2, 2020 | Exposed to the same EMB3D threatTID-329 | No feedback feed from manufacturer |
| Baxter Phoenix hemodialysis system sends treatment and prescription data in cleartext | Jun 18, 2020 | Exposed to the same EMB3D threatTID-411 | No feedback feed from manufacturer |
| Roche Accu-Chek and CoaguChek point of care handhelds expose a weakly protected service interface | Nov 6, 2018 | Exposed to the same EMB3D threatTID-324 | No feedback feed from manufacturer |
| Philips PageWriter TC cardiographs expose a hard-coded superuser password and unchecked input | Aug 16, 2018 | Exposed to the same EMB3D threatTID-329 | No feedback feed from manufacturer |
| Philips Alice 6 through R8.0.3 lacks authentication and encryption between nodes | Mar 27, 2018 | Exposed to the same EMB3D threatTID-411 | No feedback feed from manufacturer |
| Philips DoseWise Portal hard-codes its database credentials and stores logins in clear text | Aug 17, 2017 | Exposed to the same EMB3D threatTID-329 | No feedback feed from manufacturer |
| BD Kiestra PerformA and KLA Journal Service use a hard-coded database password | Mar 23, 2017 | Exposed to the same EMB3D threatTID-329 | No feedback feed from manufacturer |
| Animas OneTouch Ping insulin pump accepts replayed and unencrypted radio commands | Oct 5, 2016 | Exposed to the same EMB3D threatTID-221 | No feedback feed from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-204 Untrusted Programs Can Access Privileged OS Functions TID-205 Existing OS Tools Maliciously Used for Device Manipulation TID-213 Faulty FW/SW Update Integrity Verification TID-219 OS/Kernel Privilege Escalation TID-221 Authentication Bypass By Message Replay TID-222 Critical System Service May Be Disabled TID-224 Excessive Access via Software Diagnostic Features TID-226 Device leaks security information in logs TID-301 Applications Binaries Modified TID-303 Excessive Trust in Offboard Management/IDE Software TID-310 Remotely Accessible Unauthenticated Services TID-311 Default Credentials TID-313 Unauthenticated Session Changes Credential TID-314 Passwords Can Be Guessed Using Brute-Force Attempts TID-316 Incorrect Certificate Verification Allows Authentication Bypass TID-317 Predictable Cryptographic Key TID-318 Insecure Cryptographic Implementation TID-319 Cross Site Scripting (XSS) TID-320 SQL Injection TID-323 Path Traversal TID-324 HTTP Direct Object Reference TID-327 Out of Bounds Memory Access TID-328 Hardcoded Credentials TID-329 Improper Password Storage TID-401 Undocumented Protocol Features TID-404 Remotely Triggerable Deadlock/DoS TID-405 Network Stack Resource Exhaustion TID-406 Unauthorized Messages or Connections TID-407 Missing Message Replay Protection TID-408 Unencrypted Sensitive Data Communication TID-411 Weak/Insecure Cryptographic Protocol
CWE weaknesses
CWE-1188 Insecure Default Initialization of Resource CWE-122 Heap-based Buffer Overflow CWE-125 Out-of-bounds Read CWE-1390 Weak Authentication CWE-1392 Use of Default Credentials CWE-20 Improper Input Validation CWE-200 Exposure of Sensitive Information to an Unauthorized Actor CWE-276 Incorrect Default Permissions CWE-284 Improper Access Control CWE-287 Improper Authentication CWE-290 Authentication Bypass by Spoofing CWE-294 Authentication Bypass by Capture-replay CWE-306 Missing Authentication for Critical Function CWE-319 Cleartext Transmission of Sensitive Information CWE-321 Use of Hard-coded Cryptographic Key CWE-326 Inadequate Encryption Strength CWE-400 Uncontrolled Resource Consumption CWE-427 Uncontrolled Search Path Element CWE-476 NULL Pointer Dereference CWE-522 Insufficiently Protected Credentials CWE-639 Authorization Bypass Through User-Controlled Key CWE-787 Out-of-bounds Write CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') CWE-798 Use of Hard-coded Credentials CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') CWE-916 Use of Password Hash With Insufficient Computational Effort