LIVE FEED
A proposed class action accuses University Hospitals of negligence after an October 22 cyberattack that took its MyChart portal offline; the Cleveland patient's suit, filed October 28, claims more than a million records were exposed, a number University Hospitals has not confirmed. University of New Mexico Health Sciences Center disclosed a cyberattack October 26 that diverted ambulances for about two hours; the BYOD extortion group claims it compromised 36,000 systems, a figure UNM has not confirmed. Philips updated its Node2Shell advisory October 27 for CVE-2026-111497, the Node.js Brotli decoder flaw it first flagged October 26 against PIC iX 4.x; the advisory still names no impacted products or fixed version. Philips updated its PHP2Shell advisory October 27 for CVE-2026-109618 and CVE-2026-109619, adding five more affected products including IntelliSpace Portal V12 and Philips Axon to the seven already listed. NorthShore Health Centers disclosed a data breach to patients October 27, one of several Midwest provider notifications issued that week. Denver Health Medical Plan notified more than 238,000 members October 26 about a vendor-related data incident. A proposed class action accuses University Hospitals of negligence after an October 22 cyberattack that took its MyChart portal offline; the Cleveland patient's suit, filed October 28, claims more than a million records were exposed, a number University Hospitals has not confirmed. University of New Mexico Health Sciences Center disclosed a cyberattack October 26 that diverted ambulances for about two hours; the BYOD extortion group claims it compromised 36,000 systems, a figure UNM has not confirmed. Philips updated its Node2Shell advisory October 27 for CVE-2026-111497, the Node.js Brotli decoder flaw it first flagged October 26 against PIC iX 4.x; the advisory still names no impacted products or fixed version. Philips updated its PHP2Shell advisory October 27 for CVE-2026-109618 and CVE-2026-109619, adding five more affected products including IntelliSpace Portal V12 and Philips Axon to the seven already listed. NorthShore Health Centers disclosed a data breach to patients October 27, one of several Midwest provider notifications issued that week. Denver Health Medical Plan notified more than 238,000 members October 26 about a vendor-related data incident.
Saturday, October 31, 2026 Issue #499  ·  Est. 2025
Independent brief for device makers
Manufacturers // Medtronic

Medtronic

Medtronic in MedDevice Cyber coverage: 30 stories, 40 products named, 31 CVEs, and the company's own disclosures.

Public disclosure program
Stories
30
Products named
40
Product CVEs
31
Responses on record
0
Latest story
Oct 19, 2026

Coverage

30 stories
01
Policy

AdvaMed to Build Industry Cybersecurity Standards After a Year of Device Maker Attacks

AdvaMed's board chair says the group will treat cybersecurity like a code of ethics after Stryker, Boston Scientific, Medtronic, Abbott and Intuitive all reported attacks this year.

MedTech DiveOct 192 min read
02
Intelligence

Nine medtech companies have disclosed cyber incidents in 2026

MedTech Dive counted nine medtech companies disclosing cyber incidents in 2026, from UFP Technologies in February to Baylor Genetics in August. Stryker took a material first quarter hit and weeks of operational disruption, Medtronic notified 3,834,294 people, and social engineering opened Cook Medical, AdaptHealth, and Intuitive Surgical. Every intrusion started in corporate IT or at a third party.

MedTech DiveAug 213 min read
03
Intelligence

Medtronic’s corporate breach moves to the notification phase

Two months after an 8-K disclosed unauthorized access to corporate IT systems, Medtronic began notifying affected people. The company reports no product, patient safety or manufacturing impact and no sign of the data online.

MedTech DiveJul 22 min read
04
Vulnerability

User enumeration on the CareLink Network, found at a conference

Medtronic disclosed four flaws in the CareLink Network web layer, including observable-response user enumeration, after researchers probed a non-production instance at a security conference. Patched, no patient harm.

MedtronicDec 42 min read
05
Vulnerability

Empty passwords and cleartext storage in a home cardiac monitor

ICSMA-25-205-01: the Medtronic MyCareLink monitor stored data unencrypted, shipped a built-in account with an empty password, and deserialized untrusted data. Physical access required, no evidence of exploitation.

CISAJul 243 min read
06
Vulnerability

Medtronic disables RemoteView servers for CareLink 2090 programmer after BeyondTrust CVE-2024-12356

Medtronic said on January 30, 2025 that it disabled the servers behind the RemoteView feature of the CareLink 2090 Programmer after critical BeyondTrust flaw CVE-2024-12356; no customer action is needed.

MedtronicJan 302 min read
07
Vulnerability

Medtronic lists CareLink EHR integration and Vital Sync as affected by Mirth Connect remote code execution flaws

Medtronic said on November 30, 2023 that NextGen Mirth Connect 4.4.0 and prior, used with Mainspring Data Express CareLink EHR Integration and in Vital Sync, is affected by CVE-2023-37679 and CVE-2023-43208.

MedtronicNov 303 min read
08
Vulnerability

Medtronic Paceart Optima messaging service allows remote code execution through deserialization

CISA advisory ICSMA-23-180-01 covers CVE-2023-31222 (CVSS 9.8), deserialization of untrusted data in Medtronic Paceart Optima 1.11 and prior when the optional Paceart Messaging Service is enabled. Version 1.12 fixes it; disabling the service mitigates it.

CISAJun 293 min read
09
Vulnerability

Medtronic InterStim X and Micro clinician apps can fall back to a default password

CISA advisory ICSMA-23-061-01 reports an unverified password change (CVE-2023-25931, CVSS v3 6.4) in the Medtronic Micro Clinician (A51200) and InterStim X Clinician (A51300) apps that can reset a custom password to default. An app update available since February 23, 2023 fixes it.

CISAMar 22 min read
10
Vulnerability

Medtronic superDimension navigation system runs on unsupported Windows versions

Medtronic said on January 19, 2023 that superDimension navigation system V7 family and V61 and earlier run on Microsoft Windows platforms Microsoft no longer supports, which could allow unauthorized code execution.

MedtronicJan 193 min read
11
Vulnerability

Medtronic publishes security bulletin on ILLUMISITE fluoroscopic navigation platform vulnerabilities

Medtronic published a security bulletin on September 29, 2022 covering vulnerabilities in the ILLUMISITE fluoroscopic navigation platform.

MedtronicSep 292 min read
12
Vulnerability

Medtronic MiniMed 600 series pumps expose pairing protocol details to nearby attackers

CISA advisory ICSMA-22-263-01 covers CVE-2022-32537 (CVSS 4.8) in Medtronic MiniMed 620G, 630G, 640G and 670G insulin pumps: an attacker in wireless range during pairing could learn the protocol and later alter insulin delivery. Turning off remote bolus removes that path.

CISASep 202 min read
13
Vulnerability

Medtronic publishes DDS vulnerability bulletin for Valleylab FT10 energy platform

Medtronic published a security bulletin on June 9, 2022 covering a DDS vulnerability in the Valleylab FT10 energy platform.

MedtronicJun 92 min read
14
Vulnerability

Medtronic publishes DDS vulnerability bulletin for Valleylab FX8 generator

Medtronic published a security bulletin on June 9, 2022 covering a DDS vulnerability in the Valleylab FX8 generator.

MedtronicJun 92 min read
15
Vulnerability

Medtronic MyCareLink Smart 25000 reader allows Bluetooth authentication bypass and unsigned firmware

CISA advisory ICSMA-20-345-01 covers an authentication bypass (CVE-2020-25183, CVSS v3 8.0), a heap overflow (CVE-2020-25187, CVSS v3 8.8) and an update race allowing unsigned firmware (CVE-2020-27252, CVSS v3 8.8) in the Medtronic MyCareLink Smart Model 25000 Patient Reader. App version 5.2 delivers the fix.

CISADec 103 min read
16
Vulnerability

Medtronic warns of TiYunZong vulnerability on CT900 tablets running clinician programmer apps

Medtronic said on November 19, 2020 that the TiYunZong vulnerability on Samsung CT900 tablets affects the A610, A710, A71100 and A810 clinician programmer applications; exploitation requires visiting a malicious website in Chrome.

MedtronicNov 192 min read
17
Vulnerability

Medtronic patches Bluetooth In-Office flaws between BlueSync pacemakers and SmartSync Device Manager

Medtronic said on September 10, 2020 that two Bluetooth Low Energy flaws between BlueSync Azure, Percepta, Serena and Solera devices and the CareLink SmartSync Device Manager 24970A could disrupt programming sessions and drain battery.

MedtronicSep 103 min read
18
Vulnerability

Medtronic names FA Controller and Patient Telemetry Module in BIAS Bluetooth impersonation bulletin

Medtronic said on June 11, 2020 that the BIAS Bluetooth impersonation vulnerability affects the FA Controller (model 3537) and Patient Telemetry Module (model 97745).

MedtronicJun 112 min read
19
Vulnerability

Medtronic lists pacemakers, ICDs and glucose devices as affected by SweynTooth BLE flaws

Medtronic said on March 4, 2020 that SweynTooth BLE vulnerabilities in pre-made hardware components affect Azure, Percepta, Serena, Solera, Cobalt and Crome devices plus Guardian Connect, Envision Pro and MiniMed Connect, with communication disruption only.

MedtronicMar 42 min read
20
Vulnerability

Medtronic Valleylab FT10 and FX8 energy platforms ship hard-coded credentials and a vulnerable rssh

CISA advisory ICSMA-19-311-02 covers hard-coded credentials (CVE-2019-13543), weak descrypt password hashing (CVE-2019-13539) and a vulnerable rssh utility (CVE-2019-3464, CVE-2019-3463, CVSS 9.8) in Medtronic Valleylab FT10 and FX8 energy platforms. FT10 patches are out; FX8 patches follow in early 2020.

CISANov 74 min read
21
Vulnerability

Medtronic Valleylab FT10 and LS10 energy platforms accept inauthentic instruments through RFID bypass

CISA advisory ICSMA-19-311-01 covers CVE-2019-13531 and CVE-2019-13535 in the Medtronic Valleylab FT10 and LS10 Energy Platforms, where the RFID instrument authentication can be read and bypassed with physical access. Medtronic released a software patch.

CISANov 72 min read
22
Vulnerability

Medtronic MiniMed 508 and MiniMed 5xx and 7xx insulin pumps accept unauthenticated radio commands

CISA advisory ICSMA-19-178-01 reports improper access control (CVE-2019-10964, CVSS v3 7.1) in the RF protocol of the Medtronic MiniMed 508 and later MiniMed 511 through Veo 754 insulin pumps. There is no fix; Medtronic recommends moving patients to a newer pump.

CISAJun 273 min read
23
Vulnerability

Medtronic issues security bulletin for Conexus telemetry and monitoring accessories

Medtronic published a security bulletin on March 21, 2019 covering its Conexus telemetry and monitoring accessories.

MedtronicMar 212 min read
24
Vulnerability

Medtronic Conexus telemetry protocol lacks authentication and encryption across implanted defibrillators

CISA advisory ICSMA-19-080-01 reports that the Medtronic Conexus RF telemetry protocol implements no authentication (CVE-2019-6538, CVSS v3 9.3) and no encryption (CVE-2019-6540, CVSS v3 6.5) across Medtronic ICDs, CRT-Ds, CareLink programmers and home monitors. Patches cover a subset of implant models.

CISAMar 214 min read
25
Vulnerability

Medtronic CareLink 9790, 2090 and Encore 29901 programmers store patient data unencrypted

CISA advisory ICSMA-18-347-01 reports that all versions of the Medtronic CareLink 9790, CareLink 2090 and 29901 Encore programmers do not encrypt PII and PHI at rest (CVE-2018-18984, CVSS v3 4.6). The 9790 is end of life; Medtronic recommends data deletion and controlled disposal.

CISADec 132 min read
26
Vulnerability

Medtronic MiniMed insulin pump remote controllers allow replayed bolus commands

CISA advisory ICSMA-18-219-02 covers cleartext radio traffic (CVE-2018-10634) and a capture-replay flaw (CVE-2018-14781) in Medtronic MMT-500 and MMT-503 remote controllers paired with MiniMed insulin pumps. Medtronic told users to stop using and return the remotes.

CISAAug 73 min read
27
Vulnerability

Medtronic MyCareLink 24950 and 24952 monitors store upload credentials in a recoverable format

CISA advisory ICSMA-18-219-01 reports recoverable per-product credentials (CVE-2018-10622, CVSS v3 6.8) and weak upload verification (CVE-2018-10626, CVSS v3 4.4) in all versions of the Medtronic MyCareLink 24950 and 24952 patient monitors. Medtronic fixed the upload check server-side; no monitor firmware change is listed.

CISAAug 73 min read
28
Vulnerability

Medtronic MyCareLink monitors expose a debug port with a hard-coded OS password

CISA advisory ICSMA-18-179-01 covers a hard-coded operating system password (CVE-2018-8870) and exposed debug code (CVE-2018-8868) in Medtronic MyCareLink 24950 and 24952 monitors, all versions. Medtronic is fixing them with automatic over-the-air updates.

CISAJun 283 min read
29
Vulnerability

Medtronic N'Vision clinician programmer runs code and stores PHI on an unprotected application card

CISA advisory ICSMA-18-137-01 covers unencrypted PHI at rest (CVE-2018-8849) and a protection mechanism failure that runs modified card binaries (CVE-2018-10631) in the Medtronic 8840 N'Vision Clinician Programmer and 8870 Application Card. Medtronic has no product update.

CISAMay 173 min read
30
Vulnerability

Medtronic 2090 CareLink and 29901 Encore programmers accept updates without verifying their origin

CISA advisory ICSMA-18-058-01 covers three flaws in all versions of the Medtronic 2090 CareLink and 29901 Encore programmers, including updates fetched over HTTP without origin or integrity checks (CVE-2018-10596, CVSS v3 7.1). Medtronic disabled network updates, then shipped mitigating patches.

CISAFeb 273 min read

Products in our coverage

Products and threat intel

46

Medtronic products with the device attributes their own public documentation states, and the advisories in our coverage that share those attributes.

ProductDevice typeAttributesMatched advisories
InPen System App (MMT-8060 (iOS), MMT-8061Calculator, Drug Dose2722
Endoflip 300System, Gastrointestinal Motility (Electrical)3516
Medtronic Commander FlexSystem, Measurement, Blood-Pressure, Non-Invasive1815
LINQ II Insertable Cardiac Monitor, Zelda AI ECG Classification SystemRecorder, Event, Implantable Cardiac, (With Arrhythmia Detection)2212
LINQ II Insertable Cardiac MonitorRecorder, Event, Implantable Cardiac, (With Arrhythmia Detection)267
Endoflip 300 SystemSystem, Gastrointestinal Motility (Electrical)222
Signia Circular Adapter (Standard Length) (SIGCIRSTND)Stapler, Surgical92
Becker External Drainage and Monitoring SystemDevice, Monitoring, Intracranial Pressure20
Cardioblate Gemini-s 49260 Surgical Ablation DeviceSurgical Device, For Cutting, Coagulation, And/Or Ablation Of Tissue, Including Cardiac Tissue40
Cardioblate Gemini-s Surgical Ablation DeviceSurgical Device, For Cutting, Coagulation, And/Or Ablation Of Tissue, Including Cardiac Tissue40
Emprint Ablation System with Thermosphere TechnologySystem, Ablation, Microwave And Accessories80
Emprint SX Ablation Platform with Thermosphere TechnologySystem, Ablation, Microwave And Accessories110
Instrument Exit Point on Touch Surgery AideEndoscopic Video Imaging System / Software Component For Real Time Video Augmentation50
LigaSure RAS Maryland Jaw Vessel Sealer/Divider, Nano-coatedElectrosurgical, Cutting & Coagulation & Accessories20
LINQTM II Insertable Cardiac Monitor150
Medtronic Model 5392 External Pulse GeneratorPulse-Generator, Pacemaker, External80
MYOtherm XP Cardioplegia Delivery System with Cortiva BioActiveHeat-Exchanger, Cardiopulmonary Bypass20
NIM Vital, Nerve Integrity MonitorStimulator, Electrical, Evoked Response190
O-arm O2 Imaging SystemInterventional Fluoroscopic X-Ray System50
O-arm O2 Imaging SystemInterventional Fluoroscopic X-Ray System90
OsteoCool 2.0 RF Ablation SystemElectrosurgical, Cutting & Coagulation & Accessories30
OsteoCool RF Ablation System; OsteoCool 2.0 RF Ablation SystemElectrosurgical, Cutting & Coagulation & Accessories30
PlasmaBlade X 3.0S LIGHTElectrosurgical, Cutting & Coagulation & Accessories10
Puritan Bennett 980 Series Ventilator SystemVentilator, Continuous, Facility Use80
Puritan Bennett Cuff Pressure ManagerCuff, Tracheal Tube, Inflatable80
Reveal LINQ Insertable Cardiac MonitorRecorder, Event, Implantable Cardiac, (With Arrhythmia Detection)210
Reveal LINQTM Insertable Cardiac Monitor140
Signia StaplerStaple, Implantable80
Stealth AXiS Cranial clinical applicationNeurological Stereotaxic Instrument100
Stealth AXiS ENT clinical applicationEar, Nose, And Throat Stereotaxic Instrument40
Stealth AXiS Surgical System with Stealth AXiS Spine clinicalOrthopedic Stereotaxic Instrument80
StealthStation Cranial Software v1.3.0Neurological Stereotaxic Instrument100
StealthStation Cranial Software v1.3.2Neurological Stereotaxic Instrument120
StealthStation Cranial Software, v3.1.5Neurological Stereotaxic Instrument110
StealthStation FlexENT (9736242)Ear, Nose, And Throat Stereotaxic Instrument110
StealthStation S8 Cranial v2.0Neurological Stereotaxic Instrument120
StealthStation S8 Spine SoftwareOrthopedic Stereotaxic Instrument80
Stealthstation S8 Spine Software v1.3.0Orthopedic Stereotaxic Instrument50
StrataMR II Valves and ShuntsShunt, Central Nervous System And Components50
Streamline Unipolar Pediatric Temporary Pacing Lead (6491) StreamlineElectrode, Pacemaker, Temporary10
Synergy Cranial v2.2.9, StealthStation Cranial v3.1.4Neurological Stereotaxic Instrument70
Tri-Staple 2.0 Black Circular Reload 21mm Extra Thick (SIGCIR21XT)Stapler, Surgical40
TYRX Neuro Absorbable Antibacterial Envelope (Medium)Mesh, Surgical, Polymeric10
Valleylab FT10 Energy Platform Software Version 5.0Electrosurgical, Cutting & Coagulation & Accessories50
VitalFlow ConsoleBlood Pump For Ecmo, Long-Term (> 6 Hours) Use110
VitalFlow Set with Balance BiosurfaceExtracorporeal System For Long-Term Respiratory / Cardiopulmonary Failure30

CVEs in coverage of Medtronic products

← All manufacturers