LINQ II Insertable Cardiac Monitor
Recorder, Event, Implantable Cardiac, (With Arrhythmia Detection). Attributes come from Medtronic's own public documentation for this product.
Attributes
Signals
Properties (MITRE EMB3D)
PID-28 Device stores logs of system events and information PID-31 Application-level software is present and running on the device PID-33 Device includes interactive applications, services, or user interfaces PID-41 Device exposes remote network services PID-411 Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations
Attributes: component types
API Battery Circuit Board Generic Application Library Local Application Local Service Mobile Application Operating System Sensor Modules User Interface Wireless Module
Attributes: interface types
Wireless
Attributes: assets
Patient Data Telemetry Data
Attributes: dataflows
LINQ II ICM to external device via telemetry (ECG data, alarm/remote transmission) Patient to LINQ II ICM via MyCareLink Heart App or Patient Assistant (manual symptom recording) Patient to MyCareLink Heart App or Patient Assistant (manual symptom recording)
Matched threat intel
7
Advisories in our coverage that share an attribute with this product. A shared attribute is a lead, not a finding. The status column shows only what Medtronic has said.
| Advisory | Date | Shared | Medtronic status |
|---|---|---|---|
| Flow Neuroscience FL-100 ships a shared Bluetooth credential in every unit | Aug 13, 2026 | Same property (MITRE EMB3D)PID-411 | No feedback feed from manufacturer |
| Missing authentication lets an attacker rewrite a cardiac wearable | May 28, 2026 | Same property (MITRE EMB3D)PID-411 | No feedback feed from manufacturer |
| A hard-coded VNC password on a bioreactor, base score 9.8 | May 26, 2026 | Same property (MITRE EMB3D)PID-411 | No feedback feed from manufacturer |
| Missing authentication on a DNA sequencer control plane | Oct 21, 2025 | Same property (MITRE EMB3D)PID-411 | No feedback feed from manufacturer |
| A legacy cardiology system, end-of-service since 2014, recalled for security | Jun 10, 2025 | Same property (MITRE EMB3D)PID-411 | No feedback feed from manufacturer |
| A 10.0 SQL injection on a patient health portal | Sep 5, 2024 | Same property (MITRE EMB3D)PID-411 | No feedback feed from manufacturer |
| GE Healthcare imaging and ultrasound systems expose default service credentials | Dec 8, 2020 | Same property (MITRE EMB3D)PID-411 | No feedback feed from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-210 Device Vulnerabilities Unpatchable TID-222 Critical System Service May Be Disabled TID-310 Remotely Accessible Unauthenticated Services TID-311 Default Credentials TID-313 Unauthenticated Session Changes Credential TID-316 Incorrect Certificate Verification Allows Authentication Bypass TID-320 SQL Injection TID-324 HTTP Direct Object Reference TID-328 Hardcoded Credentials TID-329 Improper Password Storage TID-404 Remotely Triggerable Deadlock/DoS TID-406 Unauthorized Messages or Connections TID-407 Missing Message Replay Protection TID-408 Unencrypted Sensitive Data Communication
CWE weaknesses
CWE-1104 Use of Unmaintained Third Party Components CWE-1329 Reliance on Component That is Not Updateable CWE-1390 Weak Authentication CWE-1392 Use of Default Credentials CWE-287 Improper Authentication CWE-290 Authentication Bypass by Spoofing CWE-294 Authentication Bypass by Capture-replay CWE-306 Missing Authentication for Critical Function CWE-522 Insufficiently Protected Credentials CWE-798 Use of Hard-coded Credentials CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')