ZEISS CALLISTO eye
Computer assisted cataract surgery system. Attributes come from ZEISS Medical Technology's own public documentation for this product.
Attributes
Signals
Properties (MITRE EMB3D)
PID-11 Device includes a microprocessor PID-14 Device includes external peripheral interconnects (e.g., USB, Serial) PID-23 Device includes OS/kernel PID-31 Application-level software is present and running on the device PID-33 Device includes interactive applications, services, or user interfaces PID-41 Device exposes remote network services
Attributes: component types
CPU Circuit Board Display Generic Application Local Application Local Service Operating System Storage User Interface
Attributes: interface types
CANBus Ethernet TCP USB
Attributes: assets
Patient Data Software Configuration
Attributes: dataflows
Hospital network (DICOM modality worklist) to ZEISS CALLISTO eye (patient lists) IOLMaster to ZEISS CALLISTO eye (biometry reference image and data) USB Stick to ZEISS CALLISTO eye (patient lists) ZEISS CALLISTO eye to DICOM network (videos and photos) ZEISS CALLISTO eye to USB Stick (videos and photos) ZEISS CALLISTO eye to ZEISS OPMI LUMERA 700 (full remote control of surgical microscope)
Matched threat intel
18
Advisories in our coverage that share attributes with this product, strongest first: a named product or component, the same device type or lineage, then the most shared attributes. A shared attribute is a lead, not a finding. The status column shows only what ZEISS Medical Technology has said.
| # | Advisory | Date | Shared | ZEISS Medical Technology status |
|---|---|---|---|---|
| 1 | Philips IntelliVue Information Center iX B.02 can be knocked offline by repeated UDP requests | Aug 21, 2018 | Same property (MITRE EMB3D)PID-235 shared attributes: Wired network, Hospital network, Named operating system, Device exposes remote network services (PID-41) +1 | No response from manufacturer |
| 2 | Baxter ExactaMix compounders carry hard-coded admin credentials and send orders in clear text | Jun 18, 2020 | 11 shared attributesUSB port, Handles patient data, Device includes external peripheral interconnects (e.g., USB, Serial) (PID-14), Device exposes remote network services (PID-41) +7 | No response from manufacturer |
| 3 | Fujifilm FCR Capsula X and Carbon X cassette readers expose unauthenticated telnet | Apr 23, 2019 | 10 shared attributesWired network, DICOM or image parsing, Hospital network, Device exposes remote network services (PID-41) +6 | No response from manufacturer |
| 4 | Capsule Technologies SmartLinx Neuron 2 kiosk escapes to admin with a USB keyboard | Jul 14, 2020 | 8 shared attributesUSB port, Hospital network, Device includes external peripheral interconnects (e.g., USB, Serial) (PID-14), Device includes OS/kernel (PID-23) +4 | No response from manufacturer |
| 5 | Medtronic Valleylab FT10 and FX8 energy platforms ship hard-coded credentials and a vulnerable rssh | Nov 7, 2019 | 8 shared attributesWired network, File import, Device includes OS/kernel (PID-23), Operating System +4 | No response from manufacturer |
| 6 | Dräger Infinity Delta monitors allow kiosk escape, reboot loops and unauthenticated log access | Jan 22, 2019 | 8 shared attributesWired network, Hospital network, Device includes OS/kernel (PID-23), Operating System +4 | No response from manufacturer |
| 7 | Cepheid tells GeneXpert Dx 6.4a sites to switch off TLS 1.0 and TLS 1.1 | Mar 12, 2026 | 9 shared attributesWired network, Named operating system, Hospital network, Operating System +5 | No response from manufacturer |
| 8 | BD Pyxis products may still run on shared default operating system credentials | May 31, 2022 | 8 shared attributesHandles patient data, Hospital network, Wired network, Device includes OS/kernel (PID-23) +4 | No response from manufacturer |
| 9 | Karl Storz lists AIDA Bella and end-of-life AIDA HD Connect as affected by PrintNightmare | Aug 26, 2021 | 7 shared attributesNamed operating system, Wired network, Hospital network, Device includes OS/kernel (PID-23) +3 | No response from manufacturer |
| 10 | Karl Storz WD300 AIDA and WD310 AIDA C exposed to Windows IPv6 flaw CVE-2024-38063 | Nov 4, 2024 | 6 shared attributesNamed operating system, Wired network, Hospital network, Device includes OS/kernel (PID-23) +2 | No response from manufacturer |
| 11 | Baxter ExactaMix compounders run Windows builds exposed to the MS17-010 SMBv1 flaws | Dec 11, 2019 | 6 shared attributesNamed operating system, Device includes OS/kernel (PID-23), Operating System, Local Service +2 | No response from manufacturer |
| 12 | Spacelabs Xhibit Telemetry Receiver is exposed to the BlueKeep RDP flaw | Feb 18, 2020 | 7 shared attributesNamed operating system, Hospital network, Device includes OS/kernel (PID-23), Device exposes remote network services (PID-41) +3 | No response from manufacturer |
| 13 | Cepheid GeneXpert Xpress 6.4a ships without Windows speculative execution mitigations | Mar 11, 2026 | 5 shared attributesNamed operating system, Device includes OS/kernel (PID-23), Operating System, CPU +1 | No response from manufacturer |
| 14 | Medtronic Paceart Optima messaging service allows remote code execution through deserialization | Jun 29, 2023 | 8 shared attributesNamed operating system, Hospital network, Device exposes remote network services (PID-41), Device includes OS/kernel (PID-23) +4 | No response from manufacturer |
| 15 | Illumina Universal Copy Service on sequencers binds to every IP address and runs with excess privileges | Apr 27, 2023 | 8 shared attributesFile import, Device exposes remote network services (PID-41), Local Service, Operating System +4 | No response from manufacturer |
| 16 | DePuy Synthes tells Brainlab KICK users to verify MS17-010 against WannaCry and Petya | Jul 18, 2017 | 5 shared attributesNamed operating system, Wired network, Device includes OS/kernel (PID-23), Generic Application +1 | No response from manufacturer |
| 17 | Medtronic warns of TiYunZong vulnerability on CT900 tablets running clinician programmer apps | Nov 19, 2020 | 7 shared attributesHandles patient data, Named operating system, Operating System, Local Application +3 | No response from manufacturer |
| 18 | B. Braun OnlineSuite AP 3.0 and earlier allows unauthenticated file upload and DLL hijacking | Oct 22, 2020 | 5 shared attributesFile import, Named operating system, Hospital network, Generic Application +1 | No response from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-103 Microarchitectural Side Channels TID-111 Untrusted External Storage TID-202 Exploitable System Network Stack Component TID-204 Untrusted Programs Can Access Privileged OS Functions TID-205 Existing OS Tools Maliciously Used for Device Manipulation TID-210 Device Vulnerabilities Unpatchable TID-219 OS/Kernel Privilege Escalation TID-222 Critical System Service May Be Disabled TID-226 Device leaks security information in logs TID-302 Install Untrusted Application TID-305 Program Executes Dangerous System Calls TID-310 Remotely Accessible Unauthenticated Services TID-311 Default Credentials TID-323 Path Traversal TID-326 Insecure Deserialization TID-328 Hardcoded Credentials TID-329 Improper Password Storage TID-404 Remotely Triggerable Deadlock/DoS TID-405 Network Stack Resource Exhaustion TID-408 Unencrypted Sensitive Data Communication TID-411 Weak/Insecure Cryptographic Protocol
CWE weaknesses
CWE-1104 Use of Unmaintained Third Party Components CWE-1188 Insecure Default Initialization of Resource CWE-1329 Reliance on Component That is Not Updateable CWE-1392 Use of Default Credentials CWE-20 Improper Input Validation CWE-22 Improper Limitation of a Pathname to a Restricted Directory CWE-276 Incorrect Default Permissions CWE-319 Cleartext Transmission of Sensitive Information CWE-326 Inadequate Encryption Strength CWE-400 Uncontrolled Resource Consumption CWE-427 Uncontrolled Search Path Element CWE-434 Unrestricted Upload of File with Dangerous Type CWE-476 NULL Pointer Dereference CWE-502 Deserialization of Untrusted Data CWE-522 Insufficiently Protected Credentials CWE-798 Use of Hard-coded Credentials