MIM Anyware
Browser-based remote medical imaging software. Attributes come from MIM Software's own public documentation for this product.
Attributes
Properties (MITRE EMB3D)
PID-31 Application-level software is present and running on the device PID-311 Device includes the usage of a web/HTTP applications PID-33 Device includes interactive applications, services, or user interfaces PID-41 Device exposes remote network services PID-411 Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations
Attributes: component types
API Cloud Service Generic Application Local Application Local Service Platform User Interface Web Application
Attributes: interface types
TCP
Attributes: assets
Patient Data
Attributes: dataflows
Collaborator to shared imaging session (control transfer and live chat) MIM workstation to other department systems via web API MIMcloud to MIM workstations and PACS (study sharing) Web browser to MIM workstation (remote image viewing and processing, no VPN)
Matched threat intel
18
Advisories in our coverage that share attributes with this product, strongest first: a named product or component, the same device type or lineage, then the most shared attributes. A shared attribute is a lead, not a finding. The status column shows only what MIM Software has said.
| # | Advisory | Date | Shared | MIM Software status |
|---|---|---|---|---|
| 1 | User enumeration on the CareLink Network, found at a conference | Dec 4, 2025 | Same property (MITRE EMB3D)PID-3117 shared attributes: Remote, Cloud connectivity, Web interface, Remote access +3 | No response from manufacturer |
| 2 | Missing authentication on a DNA sequencer control plane | Oct 21, 2025 | Same property (MITRE EMB3D)PID-4119 shared attributes: Remote access, Cloud connectivity, Web interface, Device exposes remote network services (PID-41) +5 | No response from manufacturer |
| 3 | Change Healthcare PeerVue Web Server leaks technical details in HTTP error messages | Oct 4, 2018 | Same property (MITRE EMB3D)PID-3114 shared attributes: Web interface, Device includes the usage of a web/HTTP applications (PID-311), Web Application, TCP | No response from manufacturer |
| 4 | B. Braun SpaceStation with SpaceCom module has an open redirect in its web server | Mar 23, 2017 | Same property (MITRE EMB3D)PID-3114 shared attributes: Web interface, Device includes the usage of a web/HTTP applications (PID-311), Web Application, TCP | No response from manufacturer |
| 5 | A hard-coded VNC password on a bioreactor, base score 9.8 | May 26, 2026 | Same property (MITRE EMB3D)PID-4117 shared attributes: Remote access, Device exposes remote network services (PID-41), Device includes interactive applications, services, or user interfaces (PID-33), Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations (PID-411) +3 | No response from manufacturer |
| 6 | Philips lists IntelliSpace PACS and UDM 2 under F5 BIG-IP flaw CVE-2023-46747 | Nov 23, 2023 | 5 shared attributesImaging family, Imag, Web interface, Web Application +1 | No response from manufacturer |
| 7 | Philips Advanced Visualization Workspace V15 listed as affected by critical NGINX flaw | May 21, 2026 | 5 shared attributesImaging family, Imag, Web interface, Device includes the usage of a web/HTTP applications (PID-311) +1 | No response from manufacturer |
| 8 | Leica Biosystems Aperio VERSA and CytoVision affected by CodeMeter flaw in LAS X software | Oct 15, 2020 | 7 shared attributesImaging family, Imag, Cloud connectivity, Device exposes remote network services (PID-41) +3 | No response from manufacturer |
| 9 | Philips EncoreAnywhere exposes sensitive data in its HTTP headers | May 17, 2018 | 5 shared attributesCloud connectivity, Web interface, Device includes the usage of a web/HTTP applications (PID-311), Web Application +1 | No response from manufacturer |
| 10 | Philips lists IntelliSpace PACS and UDM under F5 iControl REST flaw CVE-2022-1388 | May 13, 2022 | 5 shared attributesImaging family, Imag, Remote access, API +1 | No response from manufacturer |
| 11 | Philips lists PACS and UDM products in its review of the F5 BIG-IP CVE-2020-5902 flaw | Jun 30, 2020 | 5 shared attributesImaging family, Imag, Web interface, Generic Application +1 | No response from manufacturer |
| 12 | MIM Admin Service RMI interface lets a local attacker run code as the service | Jun 4, 2025 | 6 shared attributesImaging family, Imag, Remote access, Local Service +2 | No response from manufacturer |
| 13 | Baxter lists five Hillrom, Welch Allyn and connectivity products exposed to Mirth Connect CVE-2023-43208 | Jan 31, 2024 | 4 shared attributesImaging family, Imag, Remote, Platform | No response from manufacturer |
| 14 | Medtronic disables RemoteView servers for CareLink 2090 programmer after BeyondTrust CVE-2024-12356 | Jan 30, 2025 | 5 shared attributesRemote, Remote access, Cloud Service, Local Application +1 | No response from manufacturer |
| 15 | Philips names Capsule Support Access Tool and Respilink in PTC Axeda Access:7 review | Mar 8, 2022 | 5 shared attributesRemote, Remote access, Cloud connectivity, Local Application +1 | No response from manufacturer |
| 16 | Canon Medical says CT, MR, VL and XR systems may be exposed to RPC runtime flaw CVE-2022-26809 | Jul 4, 2022 | 3 shared attributesImaging family, Imag, TCP | No response from manufacturer |
| 17 | Leica Biosystems flags BeyondTrust remote support flaw CVE-2026-1731 | Feb 6, 2026 | 4 shared attributesRemote, Remote access, Local Service, TCP | No response from manufacturer |
| 18 | Senate passes S. 3315, mandating MFA and encryption for every HIPAA covered entity | Sep 30, 2026 | 3 shared attributesWeb Application, Platform, Patient Data | No response from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-202 Exploitable System Network Stack Component TID-204 Untrusted Programs Can Access Privileged OS Functions TID-205 Existing OS Tools Maliciously Used for Device Manipulation TID-210 Device Vulnerabilities Unpatchable TID-219 OS/Kernel Privilege Escalation TID-222 Critical System Service May Be Disabled TID-226 Device leaks security information in logs TID-310 Remotely Accessible Unauthenticated Services TID-311 Default Credentials TID-313 Unauthenticated Session Changes Credential TID-316 Incorrect Certificate Verification Allows Authentication Bypass TID-319 Cross Site Scripting (XSS) TID-324 HTTP Direct Object Reference TID-328 Hardcoded Credentials TID-329 Improper Password Storage TID-401 Undocumented Protocol Features TID-406 Unauthorized Messages or Connections TID-408 Unencrypted Sensitive Data Communication TID-411 Weak/Insecure Cryptographic Protocol
CWE weaknesses
CWE-1104 Use of Unmaintained Third Party Components CWE-1188 Insecure Default Initialization of Resource CWE-1329 Reliance on Component That is Not Updateable CWE-1390 Weak Authentication CWE-1392 Use of Default Credentials CWE-1395 Dependency on Vulnerable Third-Party Component CWE-200 Exposure of Sensitive Information to an Unauthorized Actor CWE-276 Incorrect Default Permissions CWE-284 Improper Access Control CWE-287 Improper Authentication CWE-306 Missing Authentication for Critical Function CWE-319 Cleartext Transmission of Sensitive Information CWE-326 Inadequate Encryption Strength CWE-427 Uncontrolled Search Path Element CWE-522 Insufficiently Protected Credentials CWE-639 Authorization Bypass Through User-Controlled Key CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') CWE-798 Use of Hard-coded Credentials