Welch Allyn Connex Vital Signs Monitor
Continuous vital signs monitor. Attributes come from Baxter's own public documentation for this product.
Attributes
Signals
Properties (MITRE EMB3D)
PID-27 Device includes support for firmware/software updates PID-275 Device includes remotely-initiated firmware/software updates PID-33 Device includes interactive applications, services, or user interfaces PID-332 Device includes authenticated services PID-41 Device exposes remote network services PID-411 Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations PID-4113 Device includes cryptographic functions for sensitive data, such as encryption or authentication
Attributes: component types
API Cloud Service Display Firmware Library Local Application Local Service Sensor Modules User Interface Wireless Module
Attributes: interface types
Ethernet RFID WiFi
Attributes: assets
Credentials Patient Data Sensor Data Software Update
Attributes: dataflows
Badge to Monitor via RFID scanner (single sign-on) Monitor to Connex Central Station (monitoring and alarm management) Monitor to EMR via Wi-Fi or Ethernet (patient data) Scale to Monitor SmartCare Remote Management to Monitor (service and updates)
Matched threat intel
Top 20 of 65
Advisories in our coverage that share attributes with this product, strongest first: a named product or component, the same device type or lineage, then the most shared attributes. A shared attribute is a lead, not a finding. The status column shows only what Baxter has said.
| # | Advisory | Date | Shared | Baxter status |
|---|---|---|---|---|
| 1 | Philips IntelliVue monitors and PIC iX skip certificate revocation and crash on bad input | Sep 10, 2020 | Same property (MITRE EMB3D)PID-411310 shared attributes: Patient monitoring family, Monitor, Hospital network, Handles patient data +6 | No response from manufacturer |
| 2 | Mira’s cloud login accepted any password and returned a session token | Aug 11, 2026 | 18 shared attributesPatient monitoring family, Monitor, Handles patient data, Cloud connectivity +14 | No response from manufacturer |
| 3 | Contec CMS8000 patient monitors crash on a UDP broadcast and accept unauthenticated USB firmware | Sep 1, 2022 | 13 shared attributesPatient monitoring family, Vital, Sign, Wireless connectivity +9 | No response from manufacturer |
| 4 | A hard-coded VNC password on a bioreactor, base score 9.8 | May 26, 2026 | 14 shared attributesRemote access, User accounts, Wireless connectivity, Wired network +10 | No response from manufacturer |
| 5 | St. Jude Medical Merlin@home transmitters do not verify the Merlin.net endpoint | Jan 9, 2017 | 10 shared attributesMonitor, Cloud connectivity, Remote access, Field-updatable firmware +6 | No response from manufacturer |
| 6 | Flow Neuroscience FL-100 ships a shared Bluetooth credential in every unit | Aug 13, 2026 | 11 shared attributesWireless connectivity, User accounts, Field-updatable firmware, Device includes authenticated services (PID-332) +7 | No response from manufacturer |
| 7 | Three High Severity Flaws Hit NextGen Healthcare's Mirth Connect | Sep 10, 2026 | 14 shared attributesHandles patient data, Remote access, User accounts, HL7 or FHIR integration +10 | No response from manufacturer |
| 8 | Roche Accu-Chek and CoaguChek point of care handhelds expose a weakly protected service interface | Nov 6, 2018 | 11 shared attributesWired network, Wireless connectivity, Field-updatable firmware, Hospital network +7 | No response from manufacturer |
| 9 | Philips IntelliVue WLAN modules accept malicious firmware through a hard-coded FTP password | Sep 12, 2019 | 10 shared attributesPatient monitoring family, Monitor, Wireless connectivity, Field-updatable firmware +6 | No response from manufacturer |
| 10 | A patient monitor with a hidden backdoor that phones home | Jan 30, 2025 | 13 shared attributesPatient monitoring family, Monitor, Cloud connectivity, Wireless connectivity +9 | No response from manufacturer |
| 11 | A DICOM viewer that did not check its update server certificate | Feb 20, 2025 | 13 shared attributesField-updatable firmware, Cloud connectivity, User accounts, Handles patient data +9 | No response from manufacturer |
| 12 | B. Braun SpaceCom and Battery Pack SP with Wi-Fi carry 11 flaws from XSS to unsigned firmware | Oct 22, 2020 | 9 shared attributesWireless connectivity, Field-updatable firmware, User accounts, Device includes support for firmware/software updates (PID-27) +5 | No response from manufacturer |
| 13 | Missing authentication on a DNA sequencer control plane | Oct 21, 2025 | 12 shared attributesHandles patient data, Remote access, User accounts, Wireless connectivity +8 | No response from manufacturer |
| 14 | Baxter Sigma Spectrum infusion pumps and wireless battery modules carry hard-coded passwords | Jun 18, 2020 | 11 shared attributesWireless connectivity, User accounts, Hospital network, Device exposes remote network services (PID-41) +7 | No response from manufacturer |
| 15 | Empty passwords and cleartext storage in a home cardiac monitor | Jul 24, 2025 | 10 shared attributesMonitor, Handles patient data, User accounts, Wireless connectivity +6 | No response from manufacturer |
| 16 | GE CARESCAPE, ApexPro and CIC monitoring systems carry hard-coded SMB credentials and five more critical flaws | Jan 23, 2020 | 11 shared attributesPatient monitoring family, Monitor, Wired network, Remote access +7 | No response from manufacturer |
| 17 | Hidden BLE commands can switch off a vagus nerve stimulator’s safety limits | Aug 11, 2026 | 9 shared attributesWireless connectivity, User accounts, Field-updatable firmware, Remote access +5 | No response from manufacturer |
| 18 | Smiths Medical Medfusion 4000 syringe pump ships hard-coded wireless, FTP and Telnet credentials | Sep 7, 2017 | 8 shared attributesWireless connectivity, Wired network, Firmware, Local Service +4 | No response from manufacturer |
| 19 | B. Braun Battery Pack SP with Wi-Fi web server eval injection gives root on the pump module | Apr 13, 2023 | 7 shared attributesWireless connectivity, User accounts, HL7 or FHIR integration, Wireless Module +3 | No response from manufacturer |
| 20 | Philips IntelliVue MX40 WLAN monitors can drop local alarming after 802.11 faults | Sep 12, 2017 | 8 shared attributesPatient monitoring family, Monitor, Wireless connectivity, Hospital network +4 | No response from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-108 ROM/NVRAM Data Extraction or Modification TID-111 Untrusted External Storage TID-115 Firmware/Data Extraction via Hardware Interface TID-116 Latent Privileged Access Port TID-119 Latent Hardware Debug Port Allows Memory/Code Manipulation TID-202 Exploitable System Network Stack Component TID-204 Untrusted Programs Can Access Privileged OS Functions TID-205 Existing OS Tools Maliciously Used for Device Manipulation TID-210 Device Vulnerabilities Unpatchable TID-211 Device Allows Unauthenticated Firmware Installation TID-213 Faulty FW/SW Update Integrity Verification TID-215 Unencrypted SW/FW Updates TID-219 OS/Kernel Privilege Escalation TID-221 Authentication Bypass By Message Replay TID-222 Critical System Service May Be Disabled TID-224 Excessive Access via Software Diagnostic Features TID-225 Logs can be manipulated on the device TID-226 Device leaks security information in logs TID-303 Excessive Trust in Offboard Management/IDE Software TID-305 Program Executes Dangerous System Calls TID-310 Remotely Accessible Unauthenticated Services TID-311 Default Credentials TID-313 Unauthenticated Session Changes Credential TID-314 Passwords Can Be Guessed Using Brute-Force Attempts TID-316 Incorrect Certificate Verification Allows Authentication Bypass TID-317 Predictable Cryptographic Key TID-319 Cross Site Scripting (XSS) TID-320 SQL Injection TID-321 HTTP Application Session Hijacking TID-323 Path Traversal TID-324 HTTP Direct Object Reference TID-326 Insecure Deserialization TID-327 Out of Bounds Memory Access TID-328 Hardcoded Credentials TID-329 Improper Password Storage TID-401 Undocumented Protocol Features TID-404 Remotely Triggerable Deadlock/DoS TID-405 Network Stack Resource Exhaustion TID-406 Unauthorized Messages or Connections TID-407 Missing Message Replay Protection TID-408 Unencrypted Sensitive Data Communication TID-411 Weak/Insecure Cryptographic Protocol
CWE weaknesses
CWE-1104 Use of Unmaintained Third Party Components CWE-1191 On-Chip Debug and Test Interface With Improper Access Control CWE-1313 Hardware Allows Activation of Test or Debug Logic at Runtime CWE-1329 Reliance on Component That is Not Updateable CWE-1390 Weak Authentication CWE-1392 Use of Default Credentials CWE-1395 Dependency on Vulnerable Third-Party Component CWE-20 Improper Input Validation CWE-200 Exposure of Sensitive Information to an Unauthorized Actor CWE-22 Improper Limitation of a Pathname to a Restricted Directory CWE-284 Improper Access Control CWE-287 Improper Authentication CWE-290 Authentication Bypass by Spoofing CWE-294 Authentication Bypass by Capture-replay CWE-306 Missing Authentication for Critical Function CWE-319 Cleartext Transmission of Sensitive Information CWE-321 Use of Hard-coded Cryptographic Key CWE-326 Inadequate Encryption Strength CWE-345 Insufficient Verification of Data Authenticity CWE-400 Uncontrolled Resource Consumption CWE-427 Uncontrolled Search Path Element CWE-434 Unrestricted Upload of File with Dangerous Type CWE-476 NULL Pointer Dereference CWE-494 Download of Code Without Integrity Check CWE-502 Deserialization of Untrusted Data CWE-506 Embedded Malicious Code CWE-522 Insufficiently Protected Credentials CWE-639 Authorization Bypass Through User-Controlled Key CWE-798 Use of Hard-coded Credentials CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') CWE-912 Hidden Functionality CWE-916 Use of Password Hash With Insufficient Computational Effort