Stimulator, Electrical, Evoked Response. Attributes come from Alphatec Spine's own public documentation for this product.
Attributes
Signals
Properties (MITRE EMB3D)
PID-11 Device includes a microprocessor PID-12 Device includes Memory/Storage (external to CPU) PID-14 Device includes external peripheral interconnects (e.g., USB, Serial) PID-23 Device includes OS/kernel PID-31 Application-level software is present and running on the device PID-33 Device includes interactive applications, services, or user interfaces PID-41 Device exposes remote network services PID-411 Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations
Platform
Windows
Attributes: component types
API CPU Circuit Board Display Generic Application Local Application Local Service Memory Mobile Application Operating System Storage User Interface
Attributes: interface types
USB WiFi
Attributes: assets
Patient Data Sensor Data Software Configuration
Attributes: dataflows
Electrodes to Head Unit (nerve and muscle responses) Head Unit to Tablet application over USB or Wi-Fi (acquired waveforms, data, messages and alerts) Tablet application to Head Unit over USB or Wi-Fi (patient and procedure information, stimulus and acquisition parameter
Matched threat intel
32
Advisories in our coverage that share an attribute with this product. A shared attribute is a lead, not a finding. The status column shows only what Alphatec Spine has said.
| Advisory | Date | Shared | Alphatec Spine status |
|---|---|---|---|
| Flow Neuroscience FL-100 ships a shared Bluetooth credential in every unit | Aug 13, 2026 | Same property (MITRE EMB3D)PID-411 | No feedback feed from manufacturer |
| Hidden BLE commands can switch off a vagus nerve stimulator’s safety limits | Aug 11, 2026 | Same property (MITRE EMB3D)PID-411 | No feedback feed from manufacturer |
| Mira’s cloud login accepted any password and returned a session token | Aug 11, 2026 | Same property (MITRE EMB3D)PID-411 | No feedback feed from manufacturer |
| Missing authentication lets an attacker rewrite a cardiac wearable | May 28, 2026 | Same property (MITRE EMB3D)PID-411 | No feedback feed from manufacturer |
| A hard-coded VNC password on a bioreactor, base score 9.8 | May 26, 2026 | Same property (MITRE EMB3D)PID-411 | No feedback feed from manufacturer |
| Cepheid GeneXpert Xpress 6.4a ships without Windows speculative execution mitigations | Mar 11, 2026 | Same property (MITRE EMB3D)PID-23 | No feedback feed from manufacturer |
| A 9.8 in a power wheelchair: BLE takeover with no authentication | Dec 30, 2025 | Same property (MITRE EMB3D)PID-411 | No feedback feed from manufacturer |
| A hospital management backend leaked its own system information | Oct 28, 2025 | Same property (MITRE EMB3D)PID-411 | No feedback feed from manufacturer |
| Missing authentication on a DNA sequencer control plane | Oct 21, 2025 | Same property (MITRE EMB3D)PID-411 | No feedback feed from manufacturer |
| A heart pump controller drew a Class I recall with no attacker in sight | Oct 14, 2025 | Same property (MITRE EMB3D)PID-23 | No feedback feed from manufacturer |
| A legacy cardiology system, end-of-service since 2014, recalled for security | Jun 10, 2025 | Same property (MITRE EMB3D)PID-23 | No feedback feed from manufacturer |
| Thermo Fisher Xcalibur and Foundation driver packages allow local privilege escalation | Jan 22, 2025 | Same property (MITRE EMB3D)PID-23 | No feedback feed from manufacturer |
| Two maximum-severity flaws in a ventilation system | Nov 14, 2024 | Same property (MITRE EMB3D)PID-14 | No feedback feed from manufacturer |
| A 10.0 SQL injection on a patient health portal | Sep 5, 2024 | Same property (MITRE EMB3D)PID-411 | No feedback feed from manufacturer |
| BD BodyGuard infusion pumps can be reconfigured through the RS-232 port | Dec 1, 2022 | Same property (MITRE EMB3D)PID-14 | No feedback feed from manufacturer |
| Medtronic MiniMed 600 series pumps expose pairing protocol details to nearby attackers | Sep 20, 2022 | Same property (MITRE EMB3D)PID-411 | No feedback feed from manufacturer |
| Boston Scientific ZOOM LATITUDE PRM Model 3120 accepts unsigned software from USB and can be re-regioned | Sep 30, 2021 | Same property (MITRE EMB3D)PID-14 | No feedback feed from manufacturer |
| GE Healthcare imaging and ultrasound systems expose default service credentials | Dec 8, 2020 | Same property (MITRE EMB3D)PID-411 | No feedback feed from manufacturer |
| Capsule Technologies SmartLinx Neuron 2 kiosk escapes to admin with a USB keyboard | Jul 14, 2020 | Same property (MITRE EMB3D)PID-23 | No feedback feed from manufacturer |
| GE Healthcare ultrasound systems let a local user escape Kiosk Mode to the operating system | Feb 18, 2020 | Same property (MITRE EMB3D)PID-23 | No feedback feed from manufacturer |
| GE Aestiva and Aespire anesthesia devices can have alarms silenced through unsecured terminal servers | Jul 9, 2019 | Same property (MITRE EMB3D)PID-14 | No feedback feed from manufacturer |
| Canon Medical holds off on Meltdown and Spectre patches for its diagnostic imaging equipment | Jan 15, 2018 | Same property (MITRE EMB3D)PID-11 | No feedback feed from manufacturer |
| Philips issues WannaCry guidance naming IntelliSpace Portal Workstation IX and Event Management | May 15, 2017 | Same property (MITRE EMB3D)PID-23 | No feedback feed from manufacturer |
| Apollo Pharmacy APG-01 BT glucose meter sends readings over BLE in cleartext | Jun 18, 2026 | Same signals | No feedback feed from manufacturer |
| BPL PWS-01-BT weighing scale sends unencrypted, unauthenticated BLE data to the Be Well app | Sep 10, 2024 | Same signals | No feedback feed from manufacturer |
| SOOIL Dana Diabecare RS insulin pump and apps can be spoofed and bypassed over Bluetooth | Jan 12, 2021 | Same signals | No feedback feed from manufacturer |
| Insulet Omnipod insulin pump RF link lacks authentication | Mar 19, 2020 | Same signals | No feedback feed from manufacturer |
| Philips Veradius Unity, Pulsera and Endura Dual WAN routers use weak encryption | Dec 19, 2019 | Same signals | No feedback feed from manufacturer |
| Medtronic MiniMed 508 and MiniMed 5xx and 7xx insulin pumps accept unauthenticated radio commands | Jun 27, 2019 | Same signals | No feedback feed from manufacturer |
| Philips IntelliVue MX40 WLAN monitors can drop local alarming after 802.11 faults | Sep 12, 2017 | Same signals | No feedback feed from manufacturer |
| Empty passwords and cleartext storage in a home cardiac monitor | Jul 24, 2025 | Exposed to the same EMB3D threatTID-111 | No feedback feed from manufacturer |
| Canon Medical flags FragAttacks Wi-Fi flaws in wireless FPD and ultrasound wireless options | Jul 4, 2022 | Exposed to the same EMB3D threatTID-202 | No feedback feed from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-103 Microarchitectural Side Channels TID-111 Untrusted External Storage TID-115 Firmware/Data Extraction via Hardware Interface TID-116 Latent Privileged Access Port TID-119 Latent Hardware Debug Port Allows Memory/Code Manipulation TID-202 Exploitable System Network Stack Component TID-204 Untrusted Programs Can Access Privileged OS Functions TID-205 Existing OS Tools Maliciously Used for Device Manipulation TID-210 Device Vulnerabilities Unpatchable TID-211 Device Allows Unauthenticated Firmware Installation TID-213 Faulty FW/SW Update Integrity Verification TID-215 Unencrypted SW/FW Updates TID-219 OS/Kernel Privilege Escalation TID-222 Critical System Service May Be Disabled TID-226 Device leaks security information in logs TID-310 Remotely Accessible Unauthenticated Services TID-311 Default Credentials TID-313 Unauthenticated Session Changes Credential TID-314 Passwords Can Be Guessed Using Brute-Force Attempts TID-316 Incorrect Certificate Verification Allows Authentication Bypass TID-317 Predictable Cryptographic Key TID-320 SQL Injection TID-324 HTTP Direct Object Reference TID-326 Insecure Deserialization TID-328 Hardcoded Credentials TID-329 Improper Password Storage TID-401 Undocumented Protocol Features TID-404 Remotely Triggerable Deadlock/DoS TID-405 Network Stack Resource Exhaustion TID-406 Unauthorized Messages or Connections TID-407 Missing Message Replay Protection TID-408 Unencrypted Sensitive Data Communication TID-411 Weak/Insecure Cryptographic Protocol
CWE weaknesses
CWE-1104 Use of Unmaintained Third Party Components CWE-1188 Insecure Default Initialization of Resource CWE-1191 On-Chip Debug and Test Interface With Improper Access Control CWE-1313 Hardware Allows Activation of Test or Debug Logic at Runtime CWE-1329 Reliance on Component That is Not Updateable CWE-1390 Weak Authentication CWE-1392 Use of Default Credentials CWE-1395 Dependency on Vulnerable Third-Party Component CWE-20 Improper Input Validation CWE-200 Exposure of Sensitive Information to an Unauthorized Actor CWE-276 Incorrect Default Permissions CWE-284 Improper Access Control CWE-287 Improper Authentication CWE-290 Authentication Bypass by Spoofing CWE-294 Authentication Bypass by Capture-replay CWE-306 Missing Authentication for Critical Function CWE-319 Cleartext Transmission of Sensitive Information CWE-326 Inadequate Encryption Strength CWE-345 Insufficient Verification of Data Authenticity CWE-400 Uncontrolled Resource Consumption CWE-427 Uncontrolled Search Path Element CWE-476 NULL Pointer Dereference CWE-494 Download of Code Without Integrity Check CWE-502 Deserialization of Untrusted Data CWE-522 Insufficiently Protected Credentials CWE-639 Authorization Bypass Through User-Controlled Key CWE-798 Use of Hard-coded Credentials CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')