LIVE FEED
Dexcom began notifying 44,307 people November 13 after determining November 2 that vishing attackers reached employee accounts; letters split victims between a Social Security number and government ID group and a separate health information group, each with different remediation offers. The ransomware group Vortex added Drive Medical, the durable medical equipment maker, to its leak site November 17, claiming about 1.4 million records; the extortion deadline passed November 20 with no sample published and no company statement. Prism Medical Products began notifying as many as 1.33 million people November 17 after discovering unauthorized access to its network on October 19; exposed data may include Social Security numbers, medical and insurance information, with no attacker named. Amazon reported November 20 that autonomous AI agents it links with moderate confidence to a China nexus found and exploited a zero-day path traversal flaw in MONAI Label, an open source medical imaging tool, reaching a root shell in about 11 minutes; a fix is pending in an open pull request. FDA issued a discussion paper November 6 on cyber and AI risks in robotic medical devices with autonomous or remote teleoperation, warning that errors could execute before a supervising clinician can intervene; comments are due January 5, 2027 ahead of a December 2 to 3 workshop. The FBI issued a Flash Advisory on November 13 warning that threat actors have weaponized ARTEX, an open source AI pentesting framework, against healthcare and nine other sectors since August, with a ConnectWise Cloud Backup supply chain compromise reaching more than 2,250 downstream tenants. Dexcom began notifying 44,307 people November 13 after determining November 2 that vishing attackers reached employee accounts; letters split victims between a Social Security number and government ID group and a separate health information group, each with different remediation offers. The ransomware group Vortex added Drive Medical, the durable medical equipment maker, to its leak site November 17, claiming about 1.4 million records; the extortion deadline passed November 20 with no sample published and no company statement. Prism Medical Products began notifying as many as 1.33 million people November 17 after discovering unauthorized access to its network on October 19; exposed data may include Social Security numbers, medical and insurance information, with no attacker named. Amazon reported November 20 that autonomous AI agents it links with moderate confidence to a China nexus found and exploited a zero-day path traversal flaw in MONAI Label, an open source medical imaging tool, reaching a root shell in about 11 minutes; a fix is pending in an open pull request. FDA issued a discussion paper November 6 on cyber and AI risks in robotic medical devices with autonomous or remote teleoperation, warning that errors could execute before a supervising clinician can intervene; comments are due January 5, 2027 ahead of a December 2 to 3 workshop. The FBI issued a Flash Advisory on November 13 warning that threat actors have weaponized ARTEX, an open source AI pentesting framework, against healthcare and nine other sectors since August, with a ConnectWise Cloud Backup supply chain compromise reaching more than 2,250 downstream tenants.
Tuesday, November 24, 2026 Issue #523  ·  Est. 2025
Independent brief for device makers
Back to the advisory // Similar Products

Similar Products

Missing authentication on a DNA sequencer control plane. Products whose own public documentation makes them the same type of product as the one this advisory names, gives them the attack surface the flaw needs, or both. Within each group a named product or component and the same device type or lineage come first, then the most shared attributes, rarer ones counting for more.

This advisory's attributes

Device type
DNA and RNA sequencer control software
Signals
Handles patient data Remote access User accounts Wireless connectivity Cloud connectivity Web interface Patient or study database Hospital network Off-the-shelf software
Properties
PID-331 PID-332 PID-3322 PID-41 PID-4113 PID-411 PID-31 PID-33 PID-2321
Component types
Generic Application
Interface types
TCP
Assets
Credentials

Ranked products

36

Two reasons a product is similar. The same type of product: a peer of the product this advisory names, whatever technology it uses. The same attack surface: any product whose documentation states what this flaw needs. A product with both comes first. Other shared attributes lists products that overlap on attributes but have not been scored on either reason. A shared attribute is a lead, not a finding. The status column shows only what each manufacturer has said.

Same attack surface 11
#ProductMatchShared attributesManufacturer status
1Vscan AirGE HealthCare, System, Imaging, Pulsed Doppler, UltrasonicSame property (MITRE EMB3D)PID-41115 shared attributes
SignalHandles patient data Remote access User accounts Wireless connectivity Cloud connectivity Web interface Hospital network
PropertyDevice includes authenticated services (PID-332) Device exposes remote network services (PID-41) Device includes cryptographic functions for sensitive data, such as encryption or authentication (PID-4113) Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations (PID-411) Application-level software is present and running on the device (PID-31) Device includes interactive applications, services, or user interfaces (PID-33)
ComponentGeneric Application
AssetCredentials
No response from manufacturer
2TheraSphere 360 Y-90 Management PlatformBoston Scientific, System, Image Processing, RadiologicalSame property (MITRE EMB3D)PID-41114 shared attributes
SignalHandles patient data Remote access User accounts Cloud connectivity Web interface Patient or study database
PropertyDevice includes authenticated services (PID-332) Device exposes remote network services (PID-41) Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations (PID-411) Application-level software is present and running on the device (PID-31) Device includes interactive applications, services, or user interfaces (PID-33)
ComponentGeneric Application
InterfaceTCP
AssetCredentials
No response from manufacturer
3da Vinci Xi Surgical System, da Vinci X Surgical SystemIntuitive, System, Surgical, Computer Controlled InstrumentSame property (MITRE EMB3D)PID-41112 shared attributes
SignalRemote access User accounts Wireless connectivity Cloud connectivity Patient or study database
PropertyDevice includes authenticated services (PID-332) Device exposes remote network services (PID-41) Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations (PID-411) Application-level software is present and running on the device (PID-31) Device includes interactive applications, services, or user interfaces (PID-33)
ComponentGeneric Application
InterfaceTCP
No response from manufacturer
4BlueStar RxWelldoc, Calculator, Drug DoseSame property (MITRE EMB3D)PID-41112 shared attributes
SignalHandles patient data Remote access Wireless connectivity Cloud connectivity Web interface Patient or study database
PropertyDevice exposes remote network services (PID-41) Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations (PID-411) Application-level software is present and running on the device (PID-31) Device includes interactive applications, services, or user interfaces (PID-33)
ComponentGeneric Application
InterfaceTCP
No response from manufacturer
5Cardiologs Holter PlatformPhilips, ElectrocardiographSame property (MITRE EMB3D)PID-41110 shared attributes
SignalHandles patient data Remote access Cloud connectivity Web interface
PropertyDevice exposes remote network services (PID-41) Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations (PID-411) Application-level software is present and running on the device (PID-31) Device includes interactive applications, services, or user interfaces (PID-33)
ComponentGeneric Application
InterfaceTCP
No response from manufacturer
6Tandem Mobi insulin pump with interoperable technologyTandem Diabetes Care, Alternate Controller Enabled Insulin Infusion PumpSame property (MITRE EMB3D)PID-41110 shared attributes
SignalHandles patient data Remote access Wireless connectivity Cloud connectivity
PropertyDevice exposes remote network services (PID-41) Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations (PID-411) Application-level software is present and running on the device (PID-31) Device includes interactive applications, services, or user interfaces (PID-33)
ComponentGeneric Application
InterfaceTCP
No response from manufacturer
7BodyGuardian Remote Monitoring SystemBoston Scientific, Detector And Alarm, ArrhythmiaSame property (MITRE EMB3D)PID-4119 shared attributes
SignalHandles patient data Remote access Cloud connectivity Patient or study database Off-the-shelf software
PropertyDevice exposes remote network services (PID-41) Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations (PID-411) Application-level software is present and running on the device (PID-31)
ComponentGeneric Application
No response from manufacturer
8Medtronic Commander FlexMedtronic, System, Measurement, Blood-Pressure, Non-InvasiveSame property (MITRE EMB3D)PID-4118 shared attributes
SignalHandles patient data Remote access Wireless connectivity Cloud connectivity Patient or study database
PropertyDevice exposes remote network services (PID-41) Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations (PID-411) Device includes interactive applications, services, or user interfaces (PID-33)
No response from manufacturer
9Assert-IQ Insertable Cardiac MonitorAbbott, Recorder, Event, Implantable Cardiac, (Without Arrhythmia Detection)Same property (MITRE EMB3D)PID-4119 shared attributes
SignalHandles patient data Remote access Cloud connectivity Patient or study database
PropertyDevice exposes remote network services (PID-41) Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations (PID-411) Application-level software is present and running on the device (PID-31) Device includes interactive applications, services, or user interfaces (PID-33)
ComponentGeneric Application
No response from manufacturer
10FreeStyle Libre 3 Continuous Glucose Monitoring SystemAbbott, Integrated Continuous Glucose Monitoring System, Factory CalibratedSame property (MITRE EMB3D)PID-4119 shared attributes
SignalHandles patient data Remote access Wireless connectivity Cloud connectivity
PropertyDevice exposes remote network services (PID-41) Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations (PID-411) Application-level software is present and running on the device (PID-31) Device includes interactive applications, services, or user interfaces (PID-33)
ComponentGeneric Application
No response from manufacturer
11Homechoice Claria APD SystemBaxter, System, Peritoneal, Automatic DeliverySame property (MITRE EMB3D)PID-4115 shared attributes
SignalHandles patient data Remote access Cloud connectivity
PropertyDevice exposes remote network services (PID-41) Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations (PID-411)
No response from manufacturer
Other shared attributes 25
#ProductMatchShared attributesManufacturer status
1Infinity Gateway SuiteDräger, System, Network And Communication, Physiological Monitors14 shared attributes
SignalHandles patient data Remote access User accounts Patient or study database Hospital network Off-the-shelf software
PropertyDevice exposes remote network services (PID-41) Device includes cryptographic functions for sensitive data, such as encryption or authentication (PID-4113) Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations (PID-411) Application-level software is present and running on the device (PID-31) Device includes interactive applications, services, or user interfaces (PID-33)
ComponentGeneric Application
InterfaceTCP
AssetCredentials
No response from manufacturer
2BlueStar and BlueStar RxWelldoc, Calculator, Drug Dose13 shared attributes
SignalHandles patient data User accounts Wireless connectivity Cloud connectivity Web interface Patient or study database
PropertyDevice includes authenticated services (PID-332) Device exposes remote network services (PID-41) Application-level software is present and running on the device (PID-31) Device includes interactive applications, services, or user interfaces (PID-33)
ComponentGeneric Application
InterfaceTCP
AssetCredentials
No response from manufacturer
3Infinity CentralStation WideDräger, Monitor, Physiological, Patient(With Arrhythmia Detection Or Alarms)12 shared attributes
SignalHandles patient data User accounts Wireless connectivity Patient or study database Hospital network
PropertyDevice includes authenticated services (PID-332) Device exposes remote network services (PID-41) Device includes cryptographic functions for sensitive data, such as encryption or authentication (PID-4113) Application-level software is present and running on the device (PID-31)
ComponentGeneric Application
InterfaceTCP
AssetCredentials
No response from manufacturer
4Philips IntelliSpace CardiovascularPhilips, System, Image Processing, Radiological13 shared attributes
SignalHandles patient data Remote access User accounts Cloud connectivity Patient or study database Hospital network
PropertyDevice includes authenticated services (PID-332) Device exposes remote network services (PID-41) Device includes cryptographic functions for sensitive data, such as encryption or authentication (PID-4113) Application-level software is present and running on the device (PID-31) Device includes interactive applications, services, or user interfaces (PID-33)
ComponentGeneric Application
InterfaceTCP
No response from manufacturer
5Image Management V15Philips, System, Image Processing, Radiological13 shared attributes
SignalHandles patient data Remote access Wireless connectivity Web interface Patient or study database Hospital network
PropertyDevice includes authenticated services (PID-332) Device exposes remote network services (PID-41) Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations (PID-411) Application-level software is present and running on the device (PID-31) Device includes interactive applications, services, or user interfaces (PID-33)
ComponentGeneric Application
InterfaceTCP
No response from manufacturer
6Harmony Referral SystemTopcon Healthcare, System, Image Management, Ophthalmic12 shared attributes
SignalHandles patient data Remote access Web interface Patient or study database Hospital network Off-the-shelf software
PropertyDevice exposes remote network services (PID-41) Device includes cryptographic functions for sensitive data, such as encryption or authentication (PID-4113) Application-level software is present and running on the device (PID-31) Device includes interactive applications, services, or user interfaces (PID-33)
ComponentGeneric Application
InterfaceTCP
No response from manufacturer
7Arthrex Virtual Implant Positioning (VIP) SystemArthrex, Shoulder Arthroplasty Implantation System10 shared attributes
SignalHandles patient data User accounts Cloud connectivity Web interface Patient or study database
PropertyDevice includes authenticated services (PID-332) Device exposes remote network services (PID-41) Application-level software is present and running on the device (PID-31)
ComponentGeneric Application
AssetCredentials
No response from manufacturer
8Connected OR Hub with Device and Voice ControlStryker, Laparoscope, General & Plastic Surgery13 shared attributes
Device typecontrol
SignalHandles patient data Remote access Wireless connectivity Patient or study database Hospital network Off-the-shelf software
PropertyDevice exposes remote network services (PID-41) Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations (PID-411) Application-level software is present and running on the device (PID-31) Device includes interactive applications, services, or user interfaces (PID-33)
ComponentGeneric Application
InterfaceTCP
No response from manufacturer
9da Vinci SP Surgical SystemIntuitive, System, Surgical, Computer Controlled Instrument11 shared attributes
SignalRemote access User accounts Cloud connectivity Patient or study database
PropertyDevice includes authenticated services (PID-332) Device exposes remote network services (PID-41) Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations (PID-411) Application-level software is present and running on the device (PID-31) Device includes interactive applications, services, or user interfaces (PID-33)
ComponentGeneric Application
InterfaceTCP
No response from manufacturer
10Dose IQ Safety SoftwareBaxter, Infusion Safety Management Software11 shared attributes
SignalUser accounts Web interface Patient or study database Hospital network Off-the-shelf software
PropertyDevice includes authenticated services (PID-332) Device exposes remote network services (PID-41) Application-level software is present and running on the device (PID-31) Device includes interactive applications, services, or user interfaces (PID-33)
ComponentGeneric Application
InterfaceTCP
No response from manufacturer
11TipTraQPranaq, Ventilatory Effort Recorder10 shared attributes
SignalUser accounts Wireless connectivity Cloud connectivity Web interface
PropertyDevice includes authenticated services (PID-332) Device exposes remote network services (PID-41) Application-level software is present and running on the device (PID-31) Device includes interactive applications, services, or user interfaces (PID-33)
ComponentGeneric Application
AssetCredentials
No response from manufacturer
12LOGIQ eGE HealthCare, System, Imaging, Pulsed Doppler, Ultrasonic11 shared attributes
SignalHandles patient data User accounts Wireless connectivity Cloud connectivity Hospital network
PropertyDevice includes authenticated services (PID-332) Device exposes remote network services (PID-41) Application-level software is present and running on the device (PID-31) Device includes interactive applications, services, or user interfaces (PID-33)
ComponentGeneric Application
AssetCredentials
No response from manufacturer
13Dexcom G6 Continuous Glucose Monitoring (CGM) SystemDexCom, Integrated Continuous Glucose Monitoring System, Factory Calibrated11 shared attributes
SignalHandles patient data Remote access User accounts Wireless connectivity Cloud connectivity
PropertyDevice exposes remote network services (PID-41) Device includes cryptographic functions for sensitive data, such as encryption or authentication (PID-4113) Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations (PID-411) Application-level software is present and running on the device (PID-31) Device includes interactive applications, services, or user interfaces (PID-33)
ComponentGeneric Application
No response from manufacturer
14Zio AT deviceiRhythm, Detector And Alarm, Arrhythmia11 shared attributes
SignalHandles patient data Remote access User accounts Wireless connectivity Cloud connectivity Web interface
PropertyDevice includes authenticated services (PID-332) Device exposes remote network services (PID-41) Application-level software is present and running on the device (PID-31) Device includes interactive applications, services, or user interfaces (PID-33)
ComponentGeneric Application
No response from manufacturer
15aPROMISEExini Diagnostics11 shared attributes
SignalHandles patient data User accounts Cloud connectivity Web interface Patient or study database
PropertyDevice exposes remote network services (PID-41) Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations (PID-411) Application-level software is present and running on the device (PID-31) Device includes interactive applications, services, or user interfaces (PID-33)
ComponentGeneric Application
InterfaceTCP
No response from manufacturer
16ART-Plan+TheraPanacea, System, Planning, Radiation Therapy Treatment11 shared attributes
SignalHandles patient data User accounts Cloud connectivity Patient or study database Hospital network
PropertyDevice includes authenticated services (PID-332) Device exposes remote network services (PID-41) Application-level software is present and running on the device (PID-31) Device includes interactive applications, services, or user interfaces (PID-33)
ComponentGeneric Application
InterfaceTCP
No response from manufacturer
17Connected OR Hub with Voice ControlStryker, Laparoscope, General & Plastic Surgery12 shared attributes
Device typecontrol
SignalHandles patient data Remote access Wireless connectivity Patient or study database Hospital network
PropertyDevice exposes remote network services (PID-41) Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations (PID-411) Application-level software is present and running on the device (PID-31) Device includes interactive applications, services, or user interfaces (PID-33)
ComponentGeneric Application
InterfaceTCP
No response from manufacturer
18LUX-Dx II Insertable Cardiac Monitor (M302)Boston Scientific, Recorder, Event, Implantable Cardiac, (With Arrhythmia Detection)11 shared attributes
SignalHandles patient data Remote access Wireless connectivity Cloud connectivity Web interface Off-the-shelf software
PropertyDevice exposes remote network services (PID-41) Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations (PID-411) Application-level software is present and running on the device (PID-31) Device includes interactive applications, services, or user interfaces (PID-33)
ComponentGeneric Application
No response from manufacturer
19MOBILETT ImpactSiemens Healthineers, System, X-Ray, Mobile10 shared attributes
SignalHandles patient data User accounts Wireless connectivity Hospital network
PropertyDevice includes authenticated services (PID-332) Device exposes remote network services (PID-41) Device includes cryptographic functions for sensitive data, such as encryption or authentication (PID-4113) Application-level software is present and running on the device (PID-31) Device includes interactive applications, services, or user interfaces (PID-33)
ComponentGeneric Application
No response from manufacturer
20Arthrex Virtual Implant Positioning (VIP) System SoftwareArthrex, Shoulder Arthroplasty Implantation System10 shared attributes
SignalHandles patient data User accounts Cloud connectivity Web interface Patient or study database
PropertyDevice includes authenticated services (PID-332) Device exposes remote network services (PID-41) Application-level software is present and running on the device (PID-31) Device includes interactive applications, services, or user interfaces (PID-33)
ComponentGeneric Application
No response from manufacturer
21LUX-Dx II (M302); LUX-Dx II+Boston Scientific, Recorder, Event, Implantable Cardiac, (With Arrhythmia Detection)10 shared attributes
SignalHandles patient data Remote access Wireless connectivity Cloud connectivity Web interface Off-the-shelf software
PropertyDevice exposes remote network services (PID-41) Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations (PID-411) Application-level software is present and running on the device (PID-31)
ComponentGeneric Application
No response from manufacturer
22CoroFlow Cardiovascular SystemCoroventis Research, Computer, Diagnostic, Programmable11 shared attributes
SignalHandles patient data Wireless connectivity Patient or study database Hospital network Off-the-shelf software
PropertyDevice exposes remote network services (PID-41) Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations (PID-411) Application-level software is present and running on the device (PID-31) Device includes interactive applications, services, or user interfaces (PID-33)
ComponentGeneric Application
InterfaceTCP
No response from manufacturer
23Stelo Glucose Biosensor SystemDexCom, Integrated Continuous Glucose Monitor For Non-Intensive Glucose Management, Over-The-Counter10 shared attributes
SignalHandles patient data Wireless connectivity Cloud connectivity Patient or study database
PropertyDevice exposes remote network services (PID-41) Device includes cryptographic functions for sensitive data, such as encryption or authentication (PID-4113) Application-level software is present and running on the device (PID-31) Device includes interactive applications, services, or user interfaces (PID-33)
ComponentGeneric Application
InterfaceTCP
No response from manufacturer
24NovoPathAI, Digital Pathology Image Viewing And Management Software10 shared attributes
SignalHandles patient data Cloud connectivity Web interface Patient or study database Off-the-shelf software
PropertyDevice exposes remote network services (PID-41) Application-level software is present and running on the device (PID-31) Device includes interactive applications, services, or user interfaces (PID-33)
ComponentGeneric Application
InterfaceTCP
No response from manufacturer
25LUX-Dx Insertable Cardiac MonitorBoston Scientific, Recorder, Event, Implantable Cardiac, (With Arrhythmia Detection)10 shared attributes
SignalHandles patient data Remote access Wireless connectivity Cloud connectivity Web interface
PropertyDevice exposes remote network services (PID-41) Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations (PID-411) Application-level software is present and running on the device (PID-31) Device includes interactive applications, services, or user interfaces (PID-33)
ComponentGeneric Application
No response from manufacturer