LIVE FEED
A proposed class action accuses University Hospitals of negligence after an October 22 cyberattack that took its MyChart portal offline; the Cleveland patient's suit, filed October 28, claims more than a million records were exposed, a number University Hospitals has not confirmed. University of New Mexico Health Sciences Center disclosed a cyberattack October 26 that diverted ambulances for about two hours; the BYOD extortion group claims it compromised 36,000 systems, a figure UNM has not confirmed. Philips updated its Node2Shell advisory October 27 for CVE-2026-111497, the Node.js Brotli decoder flaw it first flagged October 26 against PIC iX 4.x; the advisory still names no impacted products or fixed version. Philips updated its PHP2Shell advisory October 27 for CVE-2026-109618 and CVE-2026-109619, adding five more affected products including IntelliSpace Portal V12 and Philips Axon to the seven already listed. NorthShore Health Centers disclosed a data breach to patients October 27, one of several Midwest provider notifications issued that week. Denver Health Medical Plan notified more than 238,000 members October 26 about a vendor-related data incident. A proposed class action accuses University Hospitals of negligence after an October 22 cyberattack that took its MyChart portal offline; the Cleveland patient's suit, filed October 28, claims more than a million records were exposed, a number University Hospitals has not confirmed. University of New Mexico Health Sciences Center disclosed a cyberattack October 26 that diverted ambulances for about two hours; the BYOD extortion group claims it compromised 36,000 systems, a figure UNM has not confirmed. Philips updated its Node2Shell advisory October 27 for CVE-2026-111497, the Node.js Brotli decoder flaw it first flagged October 26 against PIC iX 4.x; the advisory still names no impacted products or fixed version. Philips updated its PHP2Shell advisory October 27 for CVE-2026-109618 and CVE-2026-109619, adding five more affected products including IntelliSpace Portal V12 and Philips Axon to the seven already listed. NorthShore Health Centers disclosed a data breach to patients October 27, one of several Midwest provider notifications issued that week. Denver Health Medical Plan notified more than 238,000 members October 26 about a vendor-related data incident.
Saturday, October 31, 2026 Issue #499  ·  Est. 2025
Independent brief for device makers
Manufacturers // Stryker

Stryker

Stryker in MedDevice Cyber coverage: 7 stories, 3 products named, 3 CVEs, and the company's own disclosures.

Public disclosure program
Stories
7
Products named
3
Product CVEs
3
Responses on record
0
Latest story
Oct 19, 2026

Coverage

7 stories
01
Policy

AdvaMed to Build Industry Cybersecurity Standards After a Year of Device Maker Attacks

AdvaMed's board chair says the group will treat cybersecurity like a code of ethics after Stryker, Boston Scientific, Medtronic, Abbott and Intuitive all reported attacks this year.

MedTech DiveOct 192 min read
02
Intelligence

Six months later, Stryker's cyberattack still costs $45M a quarter

Stryker CFO Preston Wells told the Wells Fargo Healthcare Conference on September 10 that the March cyberattack will cost 70 to 80 basis points of third quarter sales, about $45 million, concentrated in the peripheral vascular unit built from the Inari Medical acquisition. Shares fell more than 10 percent for the week.

MassDeviceSep 112 min read
03
Intelligence

Nine medtech companies have disclosed cyber incidents in 2026

MedTech Dive counted nine medtech companies disclosing cyber incidents in 2026, from UFP Technologies in February to Baylor Genetics in August. Stryker took a material first quarter hit and weeks of operational disruption, Medtronic notified 3,834,294 people, and social engineering opened Cook Medical, AdaptHealth, and Intuitive Surgical. Every intrusion started in corporate IT or at a third party.

MedTech DiveAug 213 min read
04
Intelligence

Four months later, Stryker is still working off the backlog

Second-quarter revenue grew 9.4 percent, but the beds business is still digging out from the March outage and the backlog will not reach a manageable level until the end of the third quarter.

MedTech DiveJul 312 min read
05
Intelligence

Stryker held its guidance after a quarter it would rather forget

First-quarter sales grew 2.6 percent against a March attack that wiped 40,000 laptops and stalled shipping for weeks. One analyst put the miss near $317 million. The full-year outlook did not move.

MedTech DiveMay 13 min read
06
Intelligence

A wiper ran through Stryker’s own device management console

Stryker identified a cyberattack on March 11. Researchers say the attacker used admin access to Microsoft Intune to push wipe commands across phones and workstations, and CISA wants every operator to harden that layer now.

MedTech DiveMar 193 min read
07
Vulnerability

Stryker ships updates for KRACK Wi-Fi flaws in InTouch, S3 and Secure II hospital beds

CISA advisory ICSMA-19-029-01 lists Stryker InTouch ICU, S3 MedSurg and Secure II MedSurg beds with Bed Wireless or iBed Wireless as affected by the KRACK WPA2 key reinstallation flaws (CVE-2017-13077, CVSS 6.8). Stryker has released software updates.

CISAJan 292 min read

Products in our coverage

  • InTouch ICU Bed 2131 and 2141 (enabled with Bed Wireless) ICU hospital bed
  • S3 MedSurg Bed 3002 S3 and 3005 S3 (enabled with iBed Wireless) medical surgical hospital bed
  • Secure II MedSurg Bed 3002 (enabled with iBed Wireless) medical surgical hospital bed

Products and threat intel

34

Stryker products with the device attributes their own public documentation states, and the advisories in our coverage that share those attributes.

ProductDevice typeAttributesMatched advisories
Connected OR Hub with Device and Voice ControlLaparoscope, General & Plastic Surgery3925
Connected OR Hub with Voice ControlLaparoscope, General & Plastic Surgery2924
SDC4K Information Management System with Device and Voice ControlLaparoscope, General & Plastic Surgery219
SDC3 HD Information Management System with Wireless Device ControlLaparoscope, General & Plastic Surgery298
HipCheckAutomated Radiological Image Processing Software137
Scopis ENT SoftwareEar, Nose, And Throat Stereotaxic Instrument115
iBed Wireless with iBed MobileBed, Ac-Powered Adjustable Hospital113
Connected OR Hub with Device and Voice ControlLaparoscope, General & Plastic Surgery361
SurgiCount+ SystemImage Processing Device For Estimation Of External Blood Loss91
120V Neptune S Rover (0711-001-000)Apparatus, Suction, Ward Use, Portable, Ac-Powered60
1688 4K Camera Control Unit with Advanced Imaging ModalityLaparoscope, General & Plastic Surgery50
1688 4K Camera SystemLaparoscope, General & Plastic Surgery20
1688 4K Camera System with Advanced Imaging ModalityLaparoscope, General & Plastic Surgery40
1688 Pendulum 4K Camera Head with Integrated CouplerLaparoscope, General & Plastic Surgery40
780 nm 1688 4K Camera SystemLaparoscope, General & Plastic Surgery20
Adavanced Imaging Modality SystemLaparoscope, General & Plastic Surgery20
Blueprint Patient-Specific InstrumentationShoulder Prosthesis, Reverse Configuration90
Hydro Irrigation SystemNasopharyngoscope (Flexible Or Rigid)120
InZone IST Detachment System; IZDS Connecting CableDevice, Neurovascular Embolization30
MOLLI 2 SystemMarker, Radiographic, Implantable40
Navigated Spine InstrumentsOrthopedic Stereotaxic Instrument20
Ortho Guidance Precision Knee SoftwareOrthopedic Stereotaxic Instrument40
Remanufactured LigaSure Exact Dissector Without Nano-coating LF2019Electrosurgical, Cutting & Coagulation & Accessories10
Remanufactured LigaSure Exact Dissector, Without Nano-coatingElectrosurgical, Cutting & Coagulation & Accessories40
Remanufactured LigaSure XP Maryland Jaw Sealer/Divider WithoutElectrosurgical, Cutting & Coagulation & Accessories20
Reprocessed Advisor FL Circular Mapping Catheter, Sensor EnabledCatheter, Recording, Electrode, Reprocessed50
Reprocessed HARMONIC 1100 ShearsSingle-Use Reprocessed Ultrasonic Surgical Instruments10
Reprocessed HARMONIC 700 ShearsSingle-Use Reprocessed Ultrasonic Surgical Instruments10
Reprocessed HARMONIC ACE+ 7Single-Use Reprocessed Ultrasonic Surgical Instruments20
Reprocessed LigaSure Curved, Small Jaw, Open Sealer/DividerElectrosurgical, Cutting & Coagulation Accessories, Laparoscopic & Endoscopic, Reprocessed40
Reprocessed RD SET Adt Pulse Oximeter Sensor (4000)Oximeter, Reprocessed20
Stryker Q Guidance System with Cranial Guidance SoftwareNeurological Stereotaxic Instrument30
Trevo Trak 21 Microcatheter10
Xpedition Powered Stair ChairTransport, Patient, Powered50

CVEs in coverage of Stryker products

← All manufacturers