SDC4K Information Management System with Device and Voice Control
Laparoscope, General & Plastic Surgery. Attributes come from Stryker's own public documentation for this product.
Attributes
Signals
Properties (MITRE EMB3D)
PID-14 Device includes external peripheral interconnects (e.g., USB, Serial) PID-31 Application-level software is present and running on the device PID-33 Device includes interactive applications, services, or user interfaces PID-41 Device exposes remote network services PID-411 Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations
Attributes: component types
API Circuit Board Display Generic Application Local Application Local Service User Interface
Attributes: interface types
USB Wireless
Attributes: assets
Patient Data
Matched threat intel
9
Advisories in our coverage that share an attribute with this product. A shared attribute is a lead, not a finding. The status column shows only what Stryker has said.
| Advisory | Date | Shared | Stryker status |
|---|---|---|---|
| Mira’s cloud login accepted any password and returned a session token | Aug 11, 2026 | Same property (MITRE EMB3D)PID-411 | No feedback feed from manufacturer |
| Missing authentication lets an attacker rewrite a cardiac wearable | May 28, 2026 | Same property (MITRE EMB3D)PID-411 | No feedback feed from manufacturer |
| A hospital management backend leaked its own system information | Oct 28, 2025 | Same property (MITRE EMB3D)PID-411 | No feedback feed from manufacturer |
| A patient monitor with a hidden backdoor that phones home | Jan 30, 2025 | Same property (MITRE EMB3D)PID-411 | No feedback feed from manufacturer |
| Two maximum-severity flaws in a ventilation system | Nov 14, 2024 | Same property (MITRE EMB3D)PID-14 | No feedback feed from manufacturer |
| A 10.0 SQL injection on a patient health portal | Sep 5, 2024 | Same property (MITRE EMB3D)PID-411 | No feedback feed from manufacturer |
| Boston Scientific ZOOM LATITUDE PRM Model 3120 accepts unsigned software from USB and can be re-regioned | Sep 30, 2021 | Same property (MITRE EMB3D)PID-14 | No feedback feed from manufacturer |
| Philips Veradius Unity, Pulsera and Endura Dual WAN routers use weak encryption | Dec 19, 2019 | Same signals | No feedback feed from manufacturer |
| Philips Gemini PET/CT systems write sensitive data to removable media without access control | Mar 25, 2021 | Exposed to the same EMB3D threatTID-111 | No feedback feed from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-115 Firmware/Data Extraction via Hardware Interface TID-116 Latent Privileged Access Port TID-119 Latent Hardware Debug Port Allows Memory/Code Manipulation TID-210 Device Vulnerabilities Unpatchable TID-211 Device Allows Unauthenticated Firmware Installation TID-213 Faulty FW/SW Update Integrity Verification TID-215 Unencrypted SW/FW Updates TID-224 Excessive Access via Software Diagnostic Features TID-226 Device leaks security information in logs TID-310 Remotely Accessible Unauthenticated Services TID-313 Unauthenticated Session Changes Credential TID-314 Passwords Can Be Guessed Using Brute-Force Attempts TID-316 Incorrect Certificate Verification Allows Authentication Bypass TID-320 SQL Injection TID-324 HTTP Direct Object Reference TID-327 Out of Bounds Memory Access TID-328 Hardcoded Credentials TID-329 Improper Password Storage TID-401 Undocumented Protocol Features TID-404 Remotely Triggerable Deadlock/DoS TID-406 Unauthorized Messages or Connections TID-407 Missing Message Replay Protection TID-408 Unencrypted Sensitive Data Communication TID-411 Weak/Insecure Cryptographic Protocol
CWE weaknesses
CWE-1191 On-Chip Debug and Test Interface With Improper Access Control CWE-1313 Hardware Allows Activation of Test or Debug Logic at Runtime CWE-1390 Weak Authentication CWE-200 Exposure of Sensitive Information to an Unauthorized Actor CWE-284 Improper Access Control CWE-287 Improper Authentication CWE-290 Authentication Bypass by Spoofing CWE-294 Authentication Bypass by Capture-replay CWE-306 Missing Authentication for Critical Function CWE-319 Cleartext Transmission of Sensitive Information CWE-326 Inadequate Encryption Strength CWE-345 Insufficient Verification of Data Authenticity CWE-494 Download of Code Without Integrity Check CWE-506 Embedded Malicious Code CWE-639 Authorization Bypass Through User-Controlled Key CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') CWE-912 Hidden Functionality