TheraSphere 360 Y-90 Management Platform
System, Image Processing, Radiological. Attributes come from Boston Scientific's own public documentation for this product.
Attributes
Signals
Properties (MITRE EMB3D)
PID-31 Application-level software is present and running on the device PID-311 Device includes the usage of a web/HTTP applications PID-33 Device includes interactive applications, services, or user interfaces PID-332 Device includes authenticated services PID-41 Device exposes remote network services PID-411 Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations
Attributes: component types
API Cloud Application Generic Application Local Application Local Service User Interface Web Application
Attributes: interface types
TCP TLS
Attributes: assets
Calibration Data User Data
Attributes: dataflows
Physician to TheraSphere 360 portal via manual data input (dose, lung shunt fraction, residual waste, liver mass) User to TheraSphere 360 Platform for dose ordering of TheraSphere Microspheres vials User to TheraSphere 360 Vial Selector for dose vial orders Vial calibration date imported into TheraSphere 360 for Any Day Dosing
Matched threat intel
35
Advisories in our coverage that share an attribute with this product. A shared attribute is a lead, not a finding. The status column shows only what Boston Scientific has said.
| Advisory | Date | Shared | Boston Scientific status |
|---|---|---|---|
| Unrestricted file upload on a PACS points straight at code execution | Apr 10, 2025 | Same FDA device type | No feedback feed from manufacturer |
| Siemens Healthineers fixes seven web service flaws in syngo Dynamics before VA40G HF01 | Nov 17, 2022 | Same FDA device type | No feedback feed from manufacturer |
| Path traversal in Thermo Fisher's Torrent Suite lets authenticated users read server files | Oct 15, 2026 | Same property (MITRE EMB3D)PID-332 | No feedback feed from manufacturer |
| Mira’s cloud login accepted any password and returned a session token | Aug 11, 2026 | Same property (MITRE EMB3D)PID-411 | No feedback feed from manufacturer |
| A hard-coded VNC password on a bioreactor, base score 9.8 | May 26, 2026 | Same property (MITRE EMB3D)PID-332 | No feedback feed from manufacturer |
| Login credentials exposed on the workstation in a GE imaging viewer | Mar 16, 2026 | Same property (MITRE EMB3D)PID-332 | No feedback feed from manufacturer |
| User enumeration on the CareLink Network, found at a conference | Dec 4, 2025 | Same property (MITRE EMB3D)PID-332 | No feedback feed from manufacturer |
| Missing authentication on a DNA sequencer control plane | Oct 21, 2025 | Same property (MITRE EMB3D)PID-332 | No feedback feed from manufacturer |
| Five flaws in Sante PACS Server, and one sends credentials in cleartext | Aug 12, 2025 | Same property (MITRE EMB3D)PID-311 | No feedback feed from manufacturer |
| A 10.0 SQL injection on a patient health portal | Sep 5, 2024 | Same property (MITRE EMB3D)PID-311 | No feedback feed from manufacturer |
| BD Synapsys sessions did not expire, risking changes to patient data | May 31, 2022 | Same property (MITRE EMB3D)PID-332 | No feedback feed from manufacturer |
| LifePoint Informatics Patient Portal generated lab report PDFs from a URL and a patient ID | Apr 5, 2022 | Same property (MITRE EMB3D)PID-311 | No feedback feed from manufacturer |
| Philips Tasy EMR HTML5 has two SQL injection flaws that expose patient data | Nov 4, 2021 | Same property (MITRE EMB3D)PID-332 | No feedback feed from manufacturer |
| GE Healthcare imaging and ultrasound systems expose default service credentials | Dec 8, 2020 | Same property (MITRE EMB3D)PID-411 | No feedback feed from manufacturer |
| Philips Clinical Collaboration Platform 12.2.1 and earlier has five web and authentication flaws | Sep 17, 2020 | Same property (MITRE EMB3D)PID-311 | No feedback feed from manufacturer |
| Philips Tasy EMR and WebPortal carry cross-site scripting and information exposure flaws | Apr 30, 2019 | Same property (MITRE EMB3D)PID-311 | No feedback feed from manufacturer |
| BeaconMedaes TotalAlert Scroll Medical Air Systems expose stored passwords to unauthenticated users | May 24, 2018 | Same property (MITRE EMB3D)PID-311 | No feedback feed from manufacturer |
| Hard-coded credentials and client-side auth in nuclear-medicine software | Dec 2, 2025 | Exposed to the same EMB3D threatTID-311 | No feedback feed from manufacturer |
| Empty passwords and cleartext storage in a home cardiac monitor | Jul 24, 2025 | Exposed to the same EMB3D threatTID-328 | No feedback feed from manufacturer |
| Ossur Logic mobile app shipped hard-coded credentials and a static token in its binary | Dec 19, 2024 | Exposed to the same EMB3D threatTID-311 | No feedback feed from manufacturer |
| Default credentials across a line of diagnostic instruments | Dec 17, 2024 | Exposed to the same EMB3D threatTID-311 | No feedback feed from manufacturer |
| Unauthenticated SQL injection into an imaging database, base score 9.8 | Dec 6, 2024 | Exposed to the same EMB3D threatTID-320 | No feedback feed from manufacturer |
| Philips Vue PACS before 12.2.8.410 ships a default database password and can be overloaded | Jul 18, 2024 | Exposed to the same EMB3D threatTID-311 | No feedback feed from manufacturer |
| Softneta MedDream PACS allows unauthenticated remote code execution | Sep 5, 2023 | Exposed to the same EMB3D threatTID-324 | No feedback feed from manufacturer |
| Hillrom Welch Allyn ELI resting electrocardiographs contain hard-coded passwords | Jun 16, 2022 | Exposed to the same EMB3D threatTID-311 | No feedback feed from manufacturer |
| BD Pyxis products may still run on shared default operating system credentials | May 31, 2022 | Exposed to the same EMB3D threatTID-311 | No feedback feed from manufacturer |
| BD Viper LT system uses hard-coded credentials that expose patient data | Mar 3, 2022 | Exposed to the same EMB3D threatTID-311 | No feedback feed from manufacturer |
| BD Pyxis dispensing and supply systems ship with hard-coded credentials across 24 products | Mar 3, 2022 | Exposed to the same EMB3D threatTID-311 | No feedback feed from manufacturer |
| Swisslog Translogic Nexus Control Panel ships hard-coded root passwords and unvalidated updates | Aug 3, 2021 | Exposed to the same EMB3D threatTID-311 | No feedback feed from manufacturer |
| Philips DreamMapper 2.24 and earlier write attacker-useful details to log files | Jul 30, 2020 | Exposed to the same EMB3D threatTID-311 | No feedback feed from manufacturer |
| Baxter PrismaFlex and PrisMax send treatment data to EMR systems without encryption or authentication | Jun 18, 2020 | Exposed to the same EMB3D threatTID-328 | No feedback feed from manufacturer |
| Philips iSite and IntelliSpace PACS carry default credentials in third-party software | Nov 8, 2018 | Exposed to the same EMB3D threatTID-311 | No feedback feed from manufacturer |
| Philips PageWriter TC cardiographs expose a hard-coded superuser password and unchecked input | Aug 16, 2018 | Exposed to the same EMB3D threatTID-311 | No feedback feed from manufacturer |
| Philips DoseWise Portal hard-codes its database credentials and stores logins in clear text | Aug 17, 2017 | Exposed to the same EMB3D threatTID-311 | No feedback feed from manufacturer |
| BD Kiestra PerformA and KLA Journal Service use a hard-coded database password | Mar 23, 2017 | Exposed to the same EMB3D threatTID-311 | No feedback feed from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-111 Untrusted External Storage TID-204 Untrusted Programs Can Access Privileged OS Functions TID-205 Existing OS Tools Maliciously Used for Device Manipulation TID-211 Device Allows Unauthenticated Firmware Installation TID-219 OS/Kernel Privilege Escalation TID-221 Authentication Bypass By Message Replay TID-226 Device leaks security information in logs TID-301 Applications Binaries Modified TID-303 Excessive Trust in Offboard Management/IDE Software TID-305 Program Executes Dangerous System Calls TID-310 Remotely Accessible Unauthenticated Services TID-311 Default Credentials TID-313 Unauthenticated Session Changes Credential TID-314 Passwords Can Be Guessed Using Brute-Force Attempts TID-316 Incorrect Certificate Verification Allows Authentication Bypass TID-317 Predictable Cryptographic Key TID-319 Cross Site Scripting (XSS) TID-320 SQL Injection TID-323 Path Traversal TID-324 HTTP Direct Object Reference TID-326 Insecure Deserialization TID-327 Out of Bounds Memory Access TID-328 Hardcoded Credentials TID-329 Improper Password Storage TID-401 Undocumented Protocol Features TID-404 Remotely Triggerable Deadlock/DoS TID-405 Network Stack Resource Exhaustion TID-406 Unauthorized Messages or Connections TID-408 Unencrypted Sensitive Data Communication TID-411 Weak/Insecure Cryptographic Protocol
CWE weaknesses
CWE-1188 Insecure Default Initialization of Resource CWE-1390 Weak Authentication CWE-1392 Use of Default Credentials CWE-200 Exposure of Sensitive Information to an Unauthorized Actor CWE-22 Improper Limitation of a Pathname to a Restricted Directory CWE-276 Incorrect Default Permissions CWE-284 Improper Access Control CWE-287 Improper Authentication CWE-294 Authentication Bypass by Capture-replay CWE-306 Missing Authentication for Critical Function CWE-319 Cleartext Transmission of Sensitive Information CWE-321 Use of Hard-coded Cryptographic Key CWE-326 Inadequate Encryption Strength CWE-427 Uncontrolled Search Path Element CWE-434 Unrestricted Upload of File with Dangerous Type CWE-502 Deserialization of Untrusted Data CWE-522 Insufficiently Protected Credentials CWE-639 Authorization Bypass Through User-Controlled Key CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') CWE-798 Use of Hard-coded Credentials CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') CWE-916 Use of Password Hash With Insufficient Computational Effort