A proposed class action accuses University Hospitals of negligence after an October 22 cyberattack that took its MyChart portal offline; the Cleveland patient's suit, filed October 28, claims more than a million records were exposed, a number University Hospitals has not confirmed. University of New Mexico Health Sciences Center disclosed a cyberattack October 26 that diverted ambulances for about two hours; the BYOD extortion group claims it compromised 36,000 systems, a figure UNM has not confirmed. Philips updated its Node2Shell advisory October 27 for CVE-2026-111497, the Node.js Brotli decoder flaw it first flagged October 26 against PIC iX 4.x; the advisory still names no impacted products or fixed version. Philips updated its PHP2Shell advisory October 27 for CVE-2026-109618 and CVE-2026-109619, adding five more affected products including IntelliSpace Portal V12 and Philips Axon to the seven already listed. NorthShore Health Centers disclosed a data breach to patients October 27, one of several Midwest provider notifications issued that week. Denver Health Medical Plan notified more than 238,000 members October 26 about a vendor-related data incident. A proposed class action accuses University Hospitals of negligence after an October 22 cyberattack that took its MyChart portal offline; the Cleveland patient's suit, filed October 28, claims more than a million records were exposed, a number University Hospitals has not confirmed. University of New Mexico Health Sciences Center disclosed a cyberattack October 26 that diverted ambulances for about two hours; the BYOD extortion group claims it compromised 36,000 systems, a figure UNM has not confirmed. Philips updated its Node2Shell advisory October 27 for CVE-2026-111497, the Node.js Brotli decoder flaw it first flagged October 26 against PIC iX 4.x; the advisory still names no impacted products or fixed version. Philips updated its PHP2Shell advisory October 27 for CVE-2026-109618 and CVE-2026-109619, adding five more affected products including IntelliSpace Portal V12 and Philips Axon to the seven already listed. NorthShore Health Centers disclosed a data breach to patients October 27, one of several Midwest provider notifications issued that week. Denver Health Medical Plan notified more than 238,000 members October 26 about a vendor-related data incident.
Saturday, October 31, 2026 Issue #499  ·  Est. 2025
Independent brief for device makers

Zio AT device

Detector And Alarm, Arrhythmia. Attributes come from iRhythm's own public documentation for this product.

Attributes

Attributes: component types
Battery Cloud Service Generic Application Generic Hardware Local Application Local Service Mobile Application Sensor Modules User Interface Web Application
Attributes: interface types
Bluetooth Cellular Wireless
Attributes: assets
Report Data Sensor Data Telemetry Data User Data
Attributes: dataflows
Zio AT patch to Zio AT wireless gateway over Bluetooth (ECG data) Zio AT patch to monitoring center (returned patch for analysis and end-of-wear reporting) Zio AT wireless gateway to monitoring service over cellular (ECG data)

Matched threat intel

9

Advisories in our coverage that share an attribute with this product. A shared attribute is a lead, not a finding. The status column shows only what iRhythm has said.

AdvisoryDateSharediRhythm status
Flow Neuroscience FL-100 ships a shared Bluetooth credential in every unitAug 13, 2026Same attributes (interface and component types)Bluetooth, Mobile ApplicationNo feedback feed from manufacturer
Mira’s cloud login accepted any password and returned a session tokenAug 11, 2026Same attributes (interface and component types)Bluetooth, Mobile ApplicationNo feedback feed from manufacturer
Medtronic MyCareLink Smart 25000 reader allows Bluetooth authentication bypass and unsigned firmwareDec 10, 2020Same attributes (interface and component types)Bluetooth, Cloud ServiceNo feedback feed from manufacturer
Apollo Pharmacy APG-01 BT glucose meter sends readings over BLE in cleartextJun 18, 2026Same signalsNo feedback feed from manufacturer
Missing authentication lets an attacker rewrite a cardiac wearableMay 28, 2026Same signalsNo feedback feed from manufacturer
BPL PWS-01-BT weighing scale sends unencrypted, unauthenticated BLE data to the Be Well appSep 10, 2024Same signalsNo feedback feed from manufacturer
Fresenius lists Conox anesthesia monitor as affected by BLUFFS Bluetooth flawApr 10, 2024Same signalsNo feedback feed from manufacturer
Philips Veradius Unity, Pulsera and Endura Dual WAN routers use weak encryptionDec 19, 2019Same signalsNo feedback feed from manufacturer
Smiths Medical Medfusion 4000 syringe pump ships hard-coded wireless, FTP and Telnet credentialsSep 7, 2017Same signalsNo feedback feed from manufacturer