LIVE FEED
CISA added CVE-2026-90817, a critical REDCap flaw requiring no authentication, to its Known Exploited Vulnerabilities catalog November 18 after an unidentified actor used it to deploy the XMRig cryptominer; the research data platform drew a year-long China-nexus intrusion Google reported in June. The extortion group Falcon claimed a 104.76 GB haul from Fisher & Paykel Healthcare November 23, including device documentation and a full Salesforce CRM export, a month after the company confirmed a narrower breach limited to two employee email accounts. The extortion group n0n named GRAIL and Guardant Health, two oncology diagnostics companies, in sequential leak-site listings November 19 and 20, claiming provider and order records; neither company has confirmed the claims. Prism Medical Products began notifying as many as 1.33 million people November 17 after discovering unauthorized access to its network on October 19; exposed data may include Social Security numbers and medical and insurance information. Amazon reported November 20 that autonomous AI agents it links with moderate confidence to a China nexus found and exploited a zero-day path traversal flaw in MONAI Label, an open source medical imaging tool, reaching a root shell in about 11 minutes; a fix is pending in an open pull request. FDA issued a discussion paper November 6 on cyber and AI risks in robotic medical devices with autonomous or remote teleoperation, warning errors could execute before a supervising clinician can intervene; comments are due January 5, 2027 ahead of a December 2 to 3 workshop. CISA added CVE-2026-90817, a critical REDCap flaw requiring no authentication, to its Known Exploited Vulnerabilities catalog November 18 after an unidentified actor used it to deploy the XMRig cryptominer; the research data platform drew a year-long China-nexus intrusion Google reported in June. The extortion group Falcon claimed a 104.76 GB haul from Fisher & Paykel Healthcare November 23, including device documentation and a full Salesforce CRM export, a month after the company confirmed a narrower breach limited to two employee email accounts. The extortion group n0n named GRAIL and Guardant Health, two oncology diagnostics companies, in sequential leak-site listings November 19 and 20, claiming provider and order records; neither company has confirmed the claims. Prism Medical Products began notifying as many as 1.33 million people November 17 after discovering unauthorized access to its network on October 19; exposed data may include Social Security numbers and medical and insurance information. Amazon reported November 20 that autonomous AI agents it links with moderate confidence to a China nexus found and exploited a zero-day path traversal flaw in MONAI Label, an open source medical imaging tool, reaching a root shell in about 11 minutes; a fix is pending in an open pull request. FDA issued a discussion paper November 6 on cyber and AI risks in robotic medical devices with autonomous or remote teleoperation, warning errors could execute before a supervising clinician can intervene; comments are due January 5, 2027 ahead of a December 2 to 3 workshop.
Wednesday, November 25, 2026 Issue #524  ·  Est. 2025
Independent brief for device makers

MEDUCORE Standard²

Monitor/defibrillator. Attributes come from Weinmann Emergency's own public documentation for this product.

Attributes

Attributes: component types
API Battery Cloud Service Display Local Application Local Service Memory Storage User Interface
Attributes: interface types
Bluetooth SDIO WiFi
Attributes: assets
Patient Data
Attributes: dataflows
MEDUCORE Standard² to SD card (session data) MEDUCORE Standard² to WEINMANN Connect web portal (session data upload) MEDUCORE Standard² to digital patient data recording system over Bluetooth

Matched threat intel

16

Advisories in our coverage that share attributes with this product, strongest first: a named product or component, the same device type or lineage, then the most shared attributes. A shared attribute is a lead, not a finding. The status column shows only what Weinmann Emergency has said.

#AdvisoryDateSharedWeinmann Emergency status
1Medtronic Conexus telemetry protocol lacks authentication and encryption across implanted defibrillatorsMar 21, 2019Same property (MITRE EMB3D)PID-4116 shared attributes: Cardiology and implants family, Defibrillator, Monitor, Wireless connectivity +2No response from manufacturer
2Abbott Accent, Anthem, Assurity and Allure pacemakers get firmware fix for RF authentication bypassAug 29, 2017Same property (MITRE EMB3D)PID-4118 shared attributes: Cardiology and implants family, Wireless connectivity, Therapy delivery, Handles patient data +4No response from manufacturer
3Flow Neuroscience FL-100 ships a shared Bluetooth credential in every unitAug 13, 2026Same property (MITRE EMB3D)PID-4115 shared attributes: Wireless connectivity, Therapy delivery, Device exposes remote network services (PID-41), Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations (PID-411) +1No response from manufacturer
4LifePoint Informatics Patient Portal generated lab report PDFs from a URL and a patient IDApr 5, 2022Same property (MITRE EMB3D)PID-4114 shared attributes: Web interface, Handles patient data, Cloud connectivity, Patient DataNo response from manufacturer
5Hidden BLE commands can switch off a vagus nerve stimulator’s safety limitsAug 11, 2026Same property (MITRE EMB3D)PID-4114 shared attributes: Wireless connectivity, Therapy delivery, Device exposes remote network services (PID-41), Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations (PID-411)No response from manufacturer
6A 9.8 in a power wheelchair: BLE takeover with no authenticationDec 30, 2025Same property (MITRE EMB3D)PID-4114 shared attributes: Wireless connectivity, Therapy delivery, Device exposes remote network services (PID-41), Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations (PID-411)No response from manufacturer
7Medtronic MiniMed 600 series pumps expose pairing protocol details to nearby attackersSep 20, 2022Same property (MITRE EMB3D)PID-4112 shared attributes: Wireless connectivity, Therapy deliveryNo response from manufacturer
8Insulet Omnipod insulin pump RF link lacks authenticationMar 19, 2020Same property (MITRE EMB3D)PID-4112 shared attributes: Wireless connectivity, Therapy deliveryNo response from manufacturer
9Medtronic MiniMed 508 and MiniMed 5xx and 7xx insulin pumps accept unauthenticated radio commandsJun 27, 2019Same property (MITRE EMB3D)PID-4112 shared attributes: Wireless connectivity, Therapy deliveryNo response from manufacturer
10BD Alaris 8015 PC unit exposes stored Wi-Fi credentials on its removable flash cardJan 17, 20177 shared attributesRemovable media, Wireless connectivity, Therapy delivery, Device includes ROM, VRAM, or removable Storage (PID-123) +3No response from manufacturer
11Baxter Sigma Spectrum wireless battery modules keep Wi-Fi credentials unencrypted and skip server authenticationSep 8, 20229 shared attributesWireless connectivity, Therapy delivery, Handles patient data, Battery +5No response from manufacturer
12Medtronic N'Vision clinician programmer runs code and stores PHI on an unprotected application cardMay 17, 20186 shared attributesRemovable media, Handles patient data, Device includes ROM, VRAM, or removable Storage (PID-123), Local Application +2No response from manufacturer
13Boston Scientific ZOOM LATITUDE PRM uses a hard-coded key and leaves patient data unencryptedOct 19, 20175 shared attributesCardiology and implants family, Handles patient data, Removable media, Storage +1No response from manufacturer
14Fresenius lists Conox anesthesia monitor as affected by BLUFFS Bluetooth flawApr 10, 20246 shared attributesMonitor, Wireless connectivity, Physiological waveform processing, Handles patient data +2No response from manufacturer
15Philips lists the HeartStart Intrepid monitor/defibrillator under the Ripple20 Treck TCP/IP flawsJun 18, 20204 shared attributesCardiology and implants family, Monitor, Defibrillator, Therapy deliveryNo response from manufacturer
16Philips lists IntelliSpace ECG and Trace Master Vue under Chrome ANGLE CVE-2025-6558Jul 22, 20254 shared attributesCardiology and implants family, Web interface, Physiological waveform processing, Local ApplicationNo response from manufacturer

Threats and weaknesses in matched advisories