Agilia SP MC
Syringe pump for infusion. Attributes come from Fresenius Kabi's own public documentation for this product.
Attributes
Signals
Properties (MITRE EMB3D)
PID-28 Device stores logs of system events and information PID-33 Device includes interactive applications, services, or user interfaces PID-41 Device exposes remote network services PID-411 Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations
Attributes: component types
API Battery Display Local Application Local Service Operating System Pump User Interface Wireless Module
Attributes: interface types
WiFi
Attributes: assets
Log Data Report Data Software Configuration Telemetry Data
Attributes: dataflows
Agilia SP MC WiFi to Vigilant Software Suite via WiFi Pump to PDMS/EMR via Vigilant Bridge using HL7 Pump to Vigilant Insight (infusion data) Vigilant Centerium to pump fleet (drug library distribution and device monitoring)
Matched threat intel
Top 20 of 37
Advisories in our coverage that share attributes with this product, strongest first: a named product or component, the same device type or lineage, then the most shared attributes. A shared attribute is a lead, not a finding. The status column shows only what Fresenius Kabi has said.
| # | Advisory | Date | Shared | Fresenius Kabi status |
|---|---|---|---|---|
| 1 | Medtronic MiniMed 600 series pumps expose pairing protocol details to nearby attackers | Sep 20, 2022 | Same property (MITRE EMB3D)PID-4116 shared attributes: Infusion and medication family, Pump, Wireless connectivity, Therapy delivery +2 | No response from manufacturer |
| 2 | Insulet Omnipod insulin pump RF link lacks authentication | Mar 19, 2020 | Same property (MITRE EMB3D)PID-4116 shared attributes: Infusion and medication family, Pump, Wireless connectivity, Therapy delivery +2 | No response from manufacturer |
| 3 | Medtronic MiniMed 508 and MiniMed 5xx and 7xx insulin pumps accept unauthenticated radio commands | Jun 27, 2019 | Same property (MITRE EMB3D)PID-4116 shared attributes: Infusion and medication family, Pump, Wireless connectivity, Therapy delivery +2 | No response from manufacturer |
| 4 | Flow Neuroscience FL-100 ships a shared Bluetooth credential in every unit | Aug 13, 2026 | Same property (MITRE EMB3D)PID-4117 shared attributes: Wireless connectivity, Therapy delivery, Field-updatable firmware, Device exposes remote network services (PID-41) +3 | No response from manufacturer |
| 5 | Hidden BLE commands can switch off a vagus nerve stimulator’s safety limits | Aug 11, 2026 | Same property (MITRE EMB3D)PID-4117 shared attributes: Wireless connectivity, Therapy delivery, Field-updatable firmware, Remote access +3 | No response from manufacturer |
| 6 | BD patches KRACK Wi-Fi key reinstallation flaw across 12 Pyxis products | Apr 24, 2018 | Same signals4 shared attributes: Infusion and medication family, Wireless connectivity, Hospital network, WiFi | No response from manufacturer |
| 7 | A 9.8 in a power wheelchair: BLE takeover with no authentication | Dec 30, 2025 | Same property (MITRE EMB3D)PID-4115 shared attributes: Wireless connectivity, Therapy delivery, Field-updatable firmware, Device exposes remote network services (PID-41) +1 | No response from manufacturer |
| 8 | Abbott Accent, Anthem, Assurity and Allure pacemakers get firmware fix for RF authentication bypass | Aug 29, 2017 | Same property (MITRE EMB3D)PID-4115 shared attributes: Wireless connectivity, Therapy delivery, Field-updatable firmware, Battery +1 | No response from manufacturer |
| 9 | Canon Medical flags FragAttacks Wi-Fi flaws in wireless FPD and ultrasound wireless options | Jul 4, 2022 | Same attributes (interface and component types)WiFi, Wireless Module3 shared attributes: Wireless connectivity, Wireless Module, WiFi | No response from manufacturer |
| 10 | Medtronic Conexus telemetry protocol lacks authentication and encryption across implanted defibrillators | Mar 21, 2019 | Same property (MITRE EMB3D)PID-4113 shared attributes: Wireless connectivity, Therapy delivery, Telemetry Data | No response from manufacturer |
| 11 | Baxter PrismaFlex and PrisMax send treatment data to EMR systems without encryption or authentication | Jun 18, 2020 | Same property (MITRE EMB3D)PID-4113 shared attributes: Hospital network, Therapy delivery, Software Configuration | No response from manufacturer |
| 12 | Baxter Sigma Spectrum infusion pumps and wireless battery modules carry hard-coded passwords | Jun 18, 2020 | 15 shared attributesInfusion and medication family, Infusion, Pump, Therapy delivery +11 | No response from manufacturer |
| 13 | B. Braun SpaceCom and Battery Pack SP with Wi-Fi carry 11 flaws from XSS to unsigned firmware | Oct 22, 2020 | 10 shared attributesInfusion and medication family, Infusion, Pump, Wireless connectivity +6 | No response from manufacturer |
| 14 | Baxter Sigma Spectrum wireless battery modules keep Wi-Fi credentials unencrypted and skip server authentication | Sep 8, 2022 | 11 shared attributesInfusion and medication family, Infusion, Pump, Wireless connectivity +7 | No response from manufacturer |
| 15 | Fresenius Kabi Agilia Connect infusion accessories expose unauthenticated endpoints and weak TLS | Dec 21, 2021 | 11 shared attributesInfusion and medication family, Infusion, Pump, Wireless connectivity +7 | No response from manufacturer |
| 16 | BD Alaris System with Guardrails Suite MX has unsigned wireless firmware and tamperable datasets | Jul 13, 2023 | 11 shared attributesInfusion and medication family, Infusion, Pump, Field-updatable firmware +7 | No response from manufacturer |
| 17 | BD Alaris 8015 PC unit exposes stored Wi-Fi credentials on its removable flash card | Jan 17, 2017 | 9 shared attributesInfusion and medication family, Infusion, Wireless connectivity, Therapy delivery +5 | No response from manufacturer |
| 18 | BD Alaris 8015 PC Unit and Systems Manager session authentication flaw can knock pumps off wireless | Nov 12, 2020 | 10 shared attributesInfusion and medication family, Infusion, Pump, Wireless connectivity +6 | No response from manufacturer |
| 19 | B. Braun Battery Pack SP with Wi-Fi web server eval injection gives root on the pump module | Apr 13, 2023 | 9 shared attributesInfusion and medication family, Infusion, Pump, Wireless connectivity +5 | No response from manufacturer |
| 20 | BD Alaris PC Unit can drop off hospital Wi-Fi through a Linux kernel flaw | Jun 18, 2020 | 9 shared attributesInfusion and medication family, Infusion, Pump, Wireless connectivity +5 | No response from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-108 ROM/NVRAM Data Extraction or Modification TID-111 Untrusted External Storage TID-115 Firmware/Data Extraction via Hardware Interface TID-116 Latent Privileged Access Port TID-119 Latent Hardware Debug Port Allows Memory/Code Manipulation TID-202 Exploitable System Network Stack Component TID-204 Untrusted Programs Can Access Privileged OS Functions TID-205 Existing OS Tools Maliciously Used for Device Manipulation TID-210 Device Vulnerabilities Unpatchable TID-211 Device Allows Unauthenticated Firmware Installation TID-213 Faulty FW/SW Update Integrity Verification TID-215 Unencrypted SW/FW Updates TID-219 OS/Kernel Privilege Escalation TID-221 Authentication Bypass By Message Replay TID-222 Critical System Service May Be Disabled TID-224 Excessive Access via Software Diagnostic Features TID-226 Device leaks security information in logs TID-305 Program Executes Dangerous System Calls TID-310 Remotely Accessible Unauthenticated Services TID-311 Default Credentials TID-316 Incorrect Certificate Verification Allows Authentication Bypass TID-317 Predictable Cryptographic Key TID-319 Cross Site Scripting (XSS) TID-321 HTTP Application Session Hijacking TID-323 Path Traversal TID-324 HTTP Direct Object Reference TID-327 Out of Bounds Memory Access TID-328 Hardcoded Credentials TID-329 Improper Password Storage TID-401 Undocumented Protocol Features TID-404 Remotely Triggerable Deadlock/DoS TID-405 Network Stack Resource Exhaustion TID-406 Unauthorized Messages or Connections TID-407 Missing Message Replay Protection TID-408 Unencrypted Sensitive Data Communication TID-411 Weak/Insecure Cryptographic Protocol
CWE weaknesses
CWE-1104 Use of Unmaintained Third Party Components CWE-1191 On-Chip Debug and Test Interface With Improper Access Control CWE-1313 Hardware Allows Activation of Test or Debug Logic at Runtime CWE-1329 Reliance on Component That is Not Updateable CWE-1392 Use of Default Credentials CWE-1395 Dependency on Vulnerable Third-Party Component CWE-20 Improper Input Validation CWE-200 Exposure of Sensitive Information to an Unauthorized Actor CWE-22 Improper Limitation of a Pathname to a Restricted Directory CWE-284 Improper Access Control CWE-290 Authentication Bypass by Spoofing CWE-294 Authentication Bypass by Capture-replay CWE-306 Missing Authentication for Critical Function CWE-319 Cleartext Transmission of Sensitive Information CWE-321 Use of Hard-coded Cryptographic Key CWE-326 Inadequate Encryption Strength CWE-345 Insufficient Verification of Data Authenticity CWE-400 Uncontrolled Resource Consumption CWE-427 Uncontrolled Search Path Element CWE-434 Unrestricted Upload of File with Dangerous Type CWE-476 NULL Pointer Dereference CWE-494 Download of Code Without Integrity Check CWE-522 Insufficiently Protected Credentials CWE-639 Authorization Bypass Through User-Controlled Key CWE-798 Use of Hard-coded Credentials CWE-916 Use of Password Hash With Insufficient Computational Effort