F&P SleepStyle Auto CPAP machine
Auto-adjusting CPAP device. Attributes come from Fisher & Paykel Healthcare's own public documentation for this product.
Attributes
Signals
Properties (MITRE EMB3D)
PID-14 Device includes external peripheral interconnects (e.g., USB, Serial) PID-311 Device includes the usage of a web/HTTP applications PID-33 Device includes interactive applications, services, or user interfaces PID-411 Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations
Platform
iOS companion app: iOS app
Attributes: component types
API Circuit Board Cloud Application Display Local Application Local Service Mobile Application Pump User Interface Web Application
Attributes: interface types
Bluetooth Cellular USB
Attributes: assets
Patient Data
Attributes: dataflows
CPAP machine to SleepStyle App and Web (sleep data and therapy progress)
Matched threat intel
Top 20 of 21
Advisories in our coverage that share attributes with this product, strongest first: a named product or component, the same device type or lineage, then the most shared attributes. A shared attribute is a lead, not a finding. The status column shows only what Fisher & Paykel Healthcare has said.
| # | Advisory | Date | Shared | Fisher & Paykel Healthcare status |
|---|---|---|---|---|
| 1 | Dario Health glucose monitoring app and servers exposed cross-user health data | Feb 27, 2025 | Same property (MITRE EMB3D)PID-31111 shared attributes: Cloud connectivity, Mobile app, Handles patient data, Web interface +7 | No response from manufacturer |
| 2 | SOOIL Dana Diabecare RS insulin pump and apps can be spoofed and bypassed over Bluetooth | Jan 12, 2021 | Same property (MITRE EMB3D)PID-4118 shared attributes: Therapy delivery, Wireless connectivity, Mobile app, Home use +4 | No response from manufacturer |
| 3 | LifePoint Informatics Patient Portal generated lab report PDFs from a URL and a patient ID | Apr 5, 2022 | Same property (MITRE EMB3D)PID-3117 shared attributes: Web interface, Handles patient data, Cloud connectivity, Device includes the usage of a web/HTTP applications (PID-311) +3 | No response from manufacturer |
| 4 | Flow Neuroscience FL-100 ships a shared Bluetooth credential in every unit | Aug 13, 2026 | Same property (MITRE EMB3D)PID-4117 shared attributes: Wireless connectivity, Therapy delivery, Home use, Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations (PID-411) +3 | No response from manufacturer |
| 5 | Medtronic MyCareLink Smart 25000 reader allows Bluetooth authentication bypass and unsigned firmware | Dec 10, 2020 | Same platformiOS app7 shared attributes: Wireless connectivity, Mobile app, Cloud connectivity, Home use +3 | No response from manufacturer |
| 6 | Hidden BLE commands can switch off a vagus nerve stimulator’s safety limits | Aug 11, 2026 | Same property (MITRE EMB3D)PID-4116 shared attributes: Wireless connectivity, Therapy delivery, Home use, Mobile app +2 | No response from manufacturer |
| 7 | Missing authentication lets an attacker rewrite a cardiac wearable | May 28, 2026 | Same property (MITRE EMB3D)PID-4116 shared attributes: Wireless connectivity, Handles patient data, Mobile app, Home use +2 | No response from manufacturer |
| 8 | Innokas VC150 vital signs monitor accepts HL7 injection and stored XSS | Jan 7, 2021 | Same property (MITRE EMB3D)PID-3114 shared attributes: Web interface, USB port, Device includes the usage of a web/HTTP applications (PID-311), Web Application | No response from manufacturer |
| 9 | Apollo Pharmacy APG-01 BT glucose meter sends readings over BLE in cleartext | Jun 18, 2026 | Same property (MITRE EMB3D)PID-4116 shared attributes: Wireless connectivity, Handles patient data, Home use, Mobile app +2 | No response from manufacturer |
| 10 | Philips EncoreAnywhere exposes sensitive data in its HTTP headers | May 17, 2018 | Same property (MITRE EMB3D)PID-3114 shared attributes: Cloud connectivity, Web interface, Device includes the usage of a web/HTTP applications (PID-311), Web Application | No response from manufacturer |
| 11 | A 9.8 in a power wheelchair: BLE takeover with no authentication | Dec 30, 2025 | Same property (MITRE EMB3D)PID-4115 shared attributes: Wireless connectivity, Therapy delivery, Home use, Mobile app +1 | No response from manufacturer |
| 12 | Change Healthcare PeerVue Web Server leaks technical details in HTTP error messages | Oct 4, 2018 | Same property (MITRE EMB3D)PID-3113 shared attributes: Web interface, Device includes the usage of a web/HTTP applications (PID-311), Web Application | No response from manufacturer |
| 13 | B. Braun SpaceStation with SpaceCom module has an open redirect in its web server | Mar 23, 2017 | Same property (MITRE EMB3D)PID-3113 shared attributes: Web interface, Device includes the usage of a web/HTTP applications (PID-311), Web Application | No response from manufacturer |
| 14 | Medtronic MiniMed 600 series pumps expose pairing protocol details to nearby attackers | Sep 20, 2022 | Same property (MITRE EMB3D)PID-4113 shared attributes: Wireless connectivity, Therapy delivery, Pump | No response from manufacturer |
| 15 | Abbott Accent, Anthem, Assurity and Allure pacemakers get firmware fix for RF authentication bypass | Aug 29, 2017 | Same property (MITRE EMB3D)PID-4115 shared attributes: Wireless connectivity, Therapy delivery, Handles patient data, Local Application +1 | No response from manufacturer |
| 16 | Insulet Omnipod insulin pump RF link lacks authentication | Mar 19, 2020 | Same property (MITRE EMB3D)PID-4113 shared attributes: Wireless connectivity, Therapy delivery, Home use | No response from manufacturer |
| 17 | Medtronic MiniMed 508 and MiniMed 5xx and 7xx insulin pumps accept unauthenticated radio commands | Jun 27, 2019 | Same property (MITRE EMB3D)PID-4113 shared attributes: Wireless connectivity, Therapy delivery, Home use | No response from manufacturer |
| 18 | Medtronic Conexus telemetry protocol lacks authentication and encryption across implanted defibrillators | Mar 21, 2019 | Same property (MITRE EMB3D)PID-4113 shared attributes: Wireless connectivity, Therapy delivery, Home use | No response from manufacturer |
| 19 | BMC Medical and 3B Medical Luna CPAP Wi-Fi module crashes on malformed input | Aug 15, 2017 | 6 shared attributesRespiratory and anesthesia family, Cpap, Machine, Wireless connectivity +2 | No response from manufacturer |
| 20 | Philips DreamMapper exposes log file information in versions 2.24.x and prior | Jul 30, 2020 | 4 shared attributesRespiratory and anesthesia family, Mobile app, Home use, Mobile Application | No response from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-213 Faulty FW/SW Update Integrity Verification TID-222 Critical System Service May Be Disabled TID-224 Excessive Access via Software Diagnostic Features TID-226 Device leaks security information in logs TID-310 Remotely Accessible Unauthenticated Services TID-311 Default Credentials TID-316 Incorrect Certificate Verification Allows Authentication Bypass TID-317 Predictable Cryptographic Key TID-319 Cross Site Scripting (XSS) TID-324 HTTP Direct Object Reference TID-327 Out of Bounds Memory Access TID-328 Hardcoded Credentials TID-329 Improper Password Storage TID-401 Undocumented Protocol Features TID-404 Remotely Triggerable Deadlock/DoS TID-405 Network Stack Resource Exhaustion TID-406 Unauthorized Messages or Connections TID-407 Missing Message Replay Protection TID-408 Unencrypted Sensitive Data Communication TID-411 Weak/Insecure Cryptographic Protocol
CWE weaknesses
CWE-1188 Insecure Default Initialization of Resource CWE-1392 Use of Default Credentials CWE-20 Improper Input Validation CWE-200 Exposure of Sensitive Information to an Unauthorized Actor CWE-276 Incorrect Default Permissions CWE-284 Improper Access Control CWE-290 Authentication Bypass by Spoofing CWE-294 Authentication Bypass by Capture-replay CWE-306 Missing Authentication for Critical Function CWE-319 Cleartext Transmission of Sensitive Information CWE-326 Inadequate Encryption Strength CWE-400 Uncontrolled Resource Consumption CWE-476 NULL Pointer Dereference CWE-522 Insufficiently Protected Credentials CWE-639 Authorization Bypass Through User-Controlled Key CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') CWE-798 Use of Hard-coded Credentials