HMS9900
Patient monitor. Attributes come from Contec's own public documentation for this product.
Attributes
Signals
Properties (MITRE EMB3D)
Attributes: component types
API Cloud Service Local Service Sensor Modules User Interface
Attributes: interface types
Cellular Ethernet WiFi
Attributes: assets
Credentials Patient Data Report Data
Attributes: dataflows
HMS9900 to Cloud Health platform (examination report and measured health data)
Matched threat intel
Top 20 of 51
Advisories in our coverage that share attributes with this product, strongest first: a named product or component, the same device type or lineage, then the most shared attributes. A shared attribute is a lead, not a finding. The status column shows only what Contec has said.
| # | Advisory | Date | Shared | Contec status |
|---|---|---|---|---|
| 1 | Default credentials across a line of diagnostic instruments | Dec 17, 2024 | Same property (MITRE EMB3D)PID-332110 shared attributes: Handles patient data, Wired network, Remote access, User accounts +6 | No response from manufacturer |
| 2 | A hard-coded VNC password on a bioreactor, base score 9.8 | May 26, 2026 | Same property (MITRE EMB3D)PID-332110 shared attributes: Remote access, User accounts, Wireless connectivity, Wired network +6 | No response from manufacturer |
| 3 | Empty passwords and cleartext storage in a home cardiac monitor | Jul 24, 2025 | Same property (MITRE EMB3D)PID-332110 shared attributes: Patient, Monitor, Handles patient data, User accounts +6 | No response from manufacturer |
| 4 | Missing authentication on a DNA sequencer control plane | Oct 21, 2025 | Same property (MITRE EMB3D)PID-332110 shared attributes: Handles patient data, Remote access, User accounts, Wireless connectivity +6 | No response from manufacturer |
| 5 | Philips DoseWise Portal hard-codes its database credentials and stores logins in clear text | Aug 17, 2017 | Same property (MITRE EMB3D)PID-33216 shared attributes: Patient or study database, User accounts, Handles patient data, Device includes passwords to authenticate the users (PID-3321) +2 | No response from manufacturer |
| 6 | BIOTRONIK CardioMessenger II-S home monitors store recoverable credentials and leak them in cleartext | Jun 18, 2020 | Same property (MITRE EMB3D)PID-33217 shared attributes: Monitor, Remote access, Handles patient data, Wireless connectivity +3 | No response from manufacturer |
| 7 | BD Pyxis dispensing and supply systems ship with hard-coded credentials across 24 products | Mar 3, 2022 | Same property (MITRE EMB3D)PID-33215 shared attributes: User accounts, Handles patient data, Device includes passwords to authenticate the users (PID-3321), Credentials +1 | No response from manufacturer |
| 8 | BD Alaris Infusion Central leaves a recoverable database password after installation | Feb 16, 2023 | Same property (MITRE EMB3D)PID-33214 shared attributes: Patient or study database, User accounts, Device includes passwords to authenticate the users (PID-3321), Credentials | No response from manufacturer |
| 9 | Philips Alice 6 through R8.0.3 lacks authentication and encryption between nodes | Mar 27, 2018 | Same property (MITRE EMB3D)PID-33215 shared attributes: Wired network, User accounts, Handles patient data, Credentials +1 | No response from manufacturer |
| 10 | GE Healthcare imaging and ultrasound systems expose default service credentials | Dec 8, 2020 | Same property (MITRE EMB3D)PID-33215 shared attributes: User accounts, Remote access, Handles patient data, Credentials +1 | No response from manufacturer |
| 11 | BD Kiestra PerformA and KLA Journal Service use a hard-coded database password | Mar 23, 2017 | Same property (MITRE EMB3D)PID-33214 shared attributes: Patient or study database, Handles patient data, Credentials, Patient Data | No response from manufacturer |
| 12 | Philips Tasy EMR HTML5 has two SQL injection flaws that expose patient data | Nov 4, 2021 | Same property (MITRE EMB3D)PID-3324 shared attributes: Patient or study database, Handles patient data, User accounts, Patient Data | No response from manufacturer |
| 13 | BD Alaris 8000 PC unit stores wireless network credentials unencrypted in flash memory | Jan 17, 2017 | Exposed to the same EMB3D threatTID-3292 shared attributes: Wireless connectivity, Credentials | No response from manufacturer |
| 14 | Medtronic CareLink 9790, 2090 and Encore 29901 programmers store patient data unencrypted | Dec 13, 2018 | Exposed to the same EMB3D threatTID-3293 shared attributes: Handles patient data, Patient Data, Report Data | No response from manufacturer |
| 15 | Mira’s cloud login accepted any password and returned a session token | Aug 11, 2026 | 15 shared attributesPatient monitoring family, Monitor, Handles patient data, Cloud connectivity +11 | No response from manufacturer |
| 16 | A bundled message broker shipped with guest:guest still enabled | May 29, 2026 | 12 shared attributesWired network, User accounts, Remote access, Patient or study database +8 | No response from manufacturer |
| 17 | Contec CMS8000 patient monitors crash on a UDP broadcast and accept unauthenticated USB firmware | Sep 1, 2022 | 10 shared attributesPatient monitoring family, Patient, Monitor, Wireless connectivity +6 | No response from manufacturer |
| 18 | Philips IntelliVue WLAN modules accept malicious firmware through a hard-coded FTP password | Sep 12, 2019 | 8 shared attributesPatient monitoring family, Patient, Monitor, Wireless connectivity +4 | No response from manufacturer |
| 19 | GE CARESCAPE, ApexPro and CIC monitoring systems carry hard-coded SMB credentials and five more critical flaws | Jan 23, 2020 | 10 shared attributesPatient monitoring family, Patient, Monitor, Wired network +6 | No response from manufacturer |
| 20 | User enumeration on the CareLink Network, found at a conference | Dec 4, 2025 | 9 shared attributesPatient monitoring family, Patient, Monitor, Cloud connectivity +5 | No response from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-107 Unauthorized Direct Memory Access (DMA) TID-108 ROM/NVRAM Data Extraction or Modification TID-111 Untrusted External Storage TID-115 Firmware/Data Extraction via Hardware Interface TID-116 Latent Privileged Access Port TID-119 Latent Hardware Debug Port Allows Memory/Code Manipulation TID-202 Exploitable System Network Stack Component TID-210 Device Vulnerabilities Unpatchable TID-211 Device Allows Unauthenticated Firmware Installation TID-213 Faulty FW/SW Update Integrity Verification TID-221 Authentication Bypass By Message Replay TID-222 Critical System Service May Be Disabled TID-224 Excessive Access via Software Diagnostic Features TID-226 Device leaks security information in logs TID-301 Applications Binaries Modified TID-310 Remotely Accessible Unauthenticated Services TID-311 Default Credentials TID-312 Credential Change Mechanism Can Be Abused TID-313 Unauthenticated Session Changes Credential TID-314 Passwords Can Be Guessed Using Brute-Force Attempts TID-315 Password Retrieval Mechanism Abused TID-316 Incorrect Certificate Verification Allows Authentication Bypass TID-317 Predictable Cryptographic Key TID-318 Insecure Cryptographic Implementation TID-320 SQL Injection TID-324 HTTP Direct Object Reference TID-326 Insecure Deserialization TID-327 Out of Bounds Memory Access TID-328 Hardcoded Credentials TID-329 Improper Password Storage TID-401 Undocumented Protocol Features TID-404 Remotely Triggerable Deadlock/DoS TID-405 Network Stack Resource Exhaustion TID-406 Unauthorized Messages or Connections TID-408 Unencrypted Sensitive Data Communication TID-411 Weak/Insecure Cryptographic Protocol
CWE weaknesses
CWE-1104 Use of Unmaintained Third Party Components CWE-1188 Insecure Default Initialization of Resource CWE-1191 On-Chip Debug and Test Interface With Improper Access Control CWE-122 Heap-based Buffer Overflow CWE-125 Out-of-bounds Read CWE-1313 Hardware Allows Activation of Test or Debug Logic at Runtime CWE-1329 Reliance on Component That is Not Updateable CWE-1390 Weak Authentication CWE-1392 Use of Default Credentials CWE-1395 Dependency on Vulnerable Third-Party Component CWE-20 Improper Input Validation CWE-200 Exposure of Sensitive Information to an Unauthorized Actor CWE-276 Incorrect Default Permissions CWE-284 Improper Access Control CWE-287 Improper Authentication CWE-294 Authentication Bypass by Capture-replay CWE-306 Missing Authentication for Critical Function CWE-319 Cleartext Transmission of Sensitive Information CWE-321 Use of Hard-coded Cryptographic Key CWE-326 Inadequate Encryption Strength CWE-400 Uncontrolled Resource Consumption CWE-476 NULL Pointer Dereference CWE-502 Deserialization of Untrusted Data CWE-506 Embedded Malicious Code CWE-522 Insufficiently Protected Credentials CWE-639 Authorization Bypass Through User-Controlled Key CWE-787 Out-of-bounds Write CWE-798 Use of Hard-coded Credentials CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') CWE-912 Hidden Functionality CWE-916 Use of Password Hash With Insufficient Computational Effort