CMS8000VET Veterinary Monitor
Veterinary patient monitor. Attributes come from Contec's own public documentation for this product.
Attributes
Properties (MITRE EMB3D)
PID-28 Device stores logs of system events and information PID-33 Device includes interactive applications, services, or user interfaces PID-41 Device exposes remote network services PID-411 Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations
Attributes: component types
API Battery Display Local Application Local Service Operating System Sensor Modules User Interface
Attributes: interface types
Cellular Unknown WiFi
Attributes: assets
Log Data Sensor Data
Attributes: dataflows
Veterinary Monitor to Central Monitoring System over 3G, WiFi or wired network
Matched threat intel
Top 20 of 22
Advisories in our coverage that share attributes with this product, strongest first: a named product or component, the same device type or lineage, then the most shared attributes. A shared attribute is a lead, not a finding. The status column shows only what Contec has said.
| # | Advisory | Date | Shared | Contec status |
|---|---|---|---|---|
| 1 | Hidden BLE commands can switch off a vagus nerve stimulator’s safety limits | Aug 11, 2026 | Same property (MITRE EMB3D)PID-4114 shared attributes: Wireless connectivity, Therapy delivery, Device exposes remote network services (PID-41), Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations (PID-411) | No response from manufacturer |
| 2 | A 9.8 in a power wheelchair: BLE takeover with no authentication | Dec 30, 2025 | Same property (MITRE EMB3D)PID-4114 shared attributes: Wireless connectivity, Therapy delivery, Device exposes remote network services (PID-41), Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations (PID-411) | No response from manufacturer |
| 3 | Medtronic Conexus telemetry protocol lacks authentication and encryption across implanted defibrillators | Mar 21, 2019 | Same property (MITRE EMB3D)PID-4113 shared attributes: Monitor, Wireless connectivity, Therapy delivery | No response from manufacturer |
| 4 | Abbott Accent, Anthem, Assurity and Allure pacemakers get firmware fix for RF authentication bypass | Aug 29, 2017 | Same property (MITRE EMB3D)PID-4114 shared attributes: Wireless connectivity, Therapy delivery, Battery, Local Application | No response from manufacturer |
| 5 | Medtronic MiniMed 600 series pumps expose pairing protocol details to nearby attackers | Sep 20, 2022 | Same property (MITRE EMB3D)PID-4112 shared attributes: Wireless connectivity, Therapy delivery | No response from manufacturer |
| 6 | Insulet Omnipod insulin pump RF link lacks authentication | Mar 19, 2020 | Same property (MITRE EMB3D)PID-4112 shared attributes: Wireless connectivity, Therapy delivery | No response from manufacturer |
| 7 | Medtronic MiniMed 508 and MiniMed 5xx and 7xx insulin pumps accept unauthenticated radio commands | Jun 27, 2019 | Same property (MITRE EMB3D)PID-4112 shared attributes: Wireless connectivity, Therapy delivery | No response from manufacturer |
| 8 | Dräger Infinity Delta monitors allow kiosk escape, reboot loops and unauthenticated log access | Jan 22, 2019 | 8 shared attributesPatient monitoring family, Patient, Monitor, Wired network +4 | No response from manufacturer |
| 9 | Philips IntelliVue MX40 WLAN monitors can drop local alarming after 802.11 faults | Sep 12, 2017 | 6 shared attributesPatient monitoring family, Patient, Monitor, Wireless connectivity +2 | No response from manufacturer |
| 10 | Philips IntelliVue Information Center iX B.02 can be knocked offline by repeated UDP requests | Aug 21, 2018 | 6 shared attributesPatient monitoring family, Patient, Monitor, Wired network +2 | No response from manufacturer |
| 11 | Philips PIC iX 4.x listed as affected by two Windows DHCP vulnerabilities | Jun 22, 2026 | 5 shared attributesPatient monitoring family, Patient, Monitor, Wired network +1 | No response from manufacturer |
| 12 | Philips lists IntelliSpace PACS, UroNav and PICiX under Windows RPC flaws CVE-2023-21708 and CVE-2023-23405 | Mar 22, 2023 | 5 shared attributesPatient monitoring family, Patient, Monitor, Wired network +1 | No response from manufacturer |
| 13 | Philips lists IntelliSpace PACS, Vue PACS and ten more under Windows RPC flaw CVE-2022-26809 | Apr 26, 2022 | 5 shared attributesPatient monitoring family, Patient, Monitor, Wired network +1 | No response from manufacturer |
| 14 | Philips discloses availability flaw in e-Alert hardware 2.7 and prior | Mar 29, 2022 | 5 shared attributesPatient monitoring family, Monitor, Wired network, Device exposes remote network services (PID-41) +1 | No response from manufacturer |
| 15 | Philips lists VitalSky, PICiX and Efficia CMS200 under exploited Windows CLFS flaw CVE-2023-28252 | Apr 17, 2023 | 4 shared attributesPatient monitoring family, Patient, Monitor, Operating System | No response from manufacturer |
| 16 | Philips lists VitalSky, PICiX and IntelliSpace Portal under TPM 2.0 flaws CVE-2023-1017 and CVE-2023-1018 | Mar 24, 2023 | 4 shared attributesPatient monitoring family, Patient, Monitor, Operating System | No response from manufacturer |
| 17 | Philips lists IntelliVue Guardian, IntelliBridge and PICiX under Windows IKE flaw CVE-2022-21849 | Mar 23, 2022 | 4 shared attributesPatient monitoring family, Patient, Monitor, Operating System | No response from manufacturer |
| 18 | Philips lists PIC iX 4.x in its Node2Shell advisory and makes customers responsible for mitigations | Oct 26, 2026 | 4 shared attributesPatient monitoring family, Patient, Local Application, Operating System | No response from manufacturer |
| 19 | Philips lists PIC iX in July 2024 CrowdStrike Windows outage notice | Jul 19, 2024 | 4 shared attributesPatient monitoring family, Patient, Operating System, Local Application | No response from manufacturer |
| 20 | Philips lists IntelliVue XDS and PICiX under WinVerifyTrust signature flaw CVE-2013-3900 | May 3, 2023 | 3 shared attributesPatient monitoring family, Patient, Monitor | No response from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-202 Exploitable System Network Stack Component TID-204 Untrusted Programs Can Access Privileged OS Functions TID-205 Existing OS Tools Maliciously Used for Device Manipulation TID-210 Device Vulnerabilities Unpatchable TID-217 Remotely Initiated Updates Can Cause DoS TID-219 OS/Kernel Privilege Escalation TID-222 Critical System Service May Be Disabled TID-226 Device leaks security information in logs TID-301 Applications Binaries Modified TID-310 Remotely Accessible Unauthenticated Services TID-311 Default Credentials TID-327 Out of Bounds Memory Access TID-401 Undocumented Protocol Features TID-404 Remotely Triggerable Deadlock/DoS TID-405 Network Stack Resource Exhaustion TID-406 Unauthorized Messages or Connections TID-407 Missing Message Replay Protection TID-408 Unencrypted Sensitive Data Communication
CWE weaknesses
CWE-1104 Use of Unmaintained Third Party Components CWE-1329 Reliance on Component That is Not Updateable CWE-1395 Dependency on Vulnerable Third-Party Component CWE-20 Improper Input Validation CWE-290 Authentication Bypass by Spoofing CWE-294 Authentication Bypass by Capture-replay CWE-306 Missing Authentication for Critical Function CWE-400 Uncontrolled Resource Consumption CWE-427 Uncontrolled Search Path Element CWE-476 NULL Pointer Dereference CWE-522 Insufficiently Protected Credentials