Similar Products
Unrestricted file upload on a PACS points straight at code execution. Products whose own public documentation makes them the same type of product as the one this advisory names, gives them the attack surface the flaw needs, or both. Within each group a named product or component and the same device type or lineage come first, then the most shared attributes, rarer ones counting for more.
This advisory's attributes
Ranked products
Two reasons a product is similar. The same type of product: a peer of the product this advisory names, whatever technology it uses. The same attack surface: any product whose documentation states what this flaw needs. A product with both comes first. Other shared attributes lists products that overlap on attributes but have not been scored on either reason. A shared attribute is a lead, not a finding. The status column shows only what each manufacturer has said.
| # | Product | Match | Shared attributes | Manufacturer status |
|---|---|---|---|---|
| 1 | Image Management V15Philips, System, Image Processing, Radiological | Same FDA device type14 shared attributes | Device typeimaging family SignalFile import Patient or study database Web interface Remote access Handles patient data Hospital network PropertyDevice includes the usage of a web/HTTP applications (PID-311) Device exposes remote network services (PID-41) Application-level software is present and running on the device (PID-31) Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations (PID-411) ComponentWeb Application InterfaceTCP AssetPatient Data | No response from manufacturer |
| 2 | Image SuiteCarestream Health, System, Image Processing, Radiological | Same FDA device type12 shared attributes | Device typeimaging family SignalFile import Patient or study database Web interface Handles patient data Hospital network PropertyDevice includes the usage of a web/HTTP applications (PID-311) Device exposes remote network services (PID-41) Application-level software is present and running on the device (PID-31) ComponentWeb Application InterfaceTCP AssetPatient Data | No response from manufacturer |
| 3 | aPROMISEExini Diagnostics | Same FDA device type11 shared attributes | SignalFile import Patient or study database Web interface Handles patient data PropertyDevice includes the usage of a web/HTTP applications (PID-311) Device exposes remote network services (PID-41) Application-level software is present and running on the device (PID-31) Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations (PID-411) ComponentWeb Application InterfaceTCP AssetPatient Data | No response from manufacturer |
| 4 | Philips IntelliSpace CardiovascularPhilips, System, Image Processing, Radiological | Same FDA device type10 shared attributes | SignalFile import Patient or study database Remote access Handles patient data Hospital network PropertyDevice exposes remote network services (PID-41) Application-level software is present and running on the device (PID-31) ComponentWeb Application InterfaceTCP AssetPatient Data | No response from manufacturer |
| # | Product | Match | Shared attributes | Manufacturer status |
|---|---|---|---|---|
| 1 | TheraSphere 360 Y-90 Management PlatformBoston Scientific, System, Image Processing, Radiological | Same FDA device type12 shared attributes | Device typeimaging family SignalPatient or study database Web interface Remote access Handles patient data PropertyDevice includes the usage of a web/HTTP applications (PID-311) Device exposes remote network services (PID-41) Application-level software is present and running on the device (PID-31) Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations (PID-411) ComponentWeb Application InterfaceTCP AssetPatient Data | No response from manufacturer |
| 2 | ViewPoint 6GE HealthCare, System, Image Processing, Radiological | Same FDA device type12 shared attributes | Device typeimaging family SignalFile import Patient or study database Wired network Handles patient data Hospital network Off-the-shelf software PropertyDevice exposes remote network services (PID-41) Application-level software is present and running on the device (PID-31) ComponentStorage InterfaceTCP AssetPatient Data | No response from manufacturer |
| 3 | syngo.via View&GO VA40ASiemens Healthineers, System, Image Processing, Radiological | Same FDA device type8 shared attributes | Device typeimaging family SignalFile import Patient or study database Handles patient data Hospital network PropertyDevice exposes remote network services (PID-41) Application-level software is present and running on the device (PID-31) AssetPatient Data | No response from manufacturer |
| 4 | ManufacturerAlphatec Spine | Same FDA device type6 shared attributes | SignalFile import Patient or study database Handles patient data PropertyDevice exposes remote network services (PID-41) Application-level software is present and running on the device (PID-31) AssetPatient Data | No response from manufacturer |
| 5 | FlightPlan for LiverGE HealthCare, System, Image Processing, Radiological | Same FDA device type4 shared attributes | Device typeimaging family SignalFile import PropertyApplication-level software is present and running on the device (PID-31) AssetPatient Data | No response from manufacturer |
| # | Product | Match | Shared attributes | Manufacturer status |
|---|---|---|---|---|
| 1 | Synapse PACSFujifilm Healthcare, Automated Radiological Image Processing Software | Exposed to the same EMB3D threatTID-32315 shared attributes | Device typeimaging family pac SignalFile import Patient or study database Web interface Wired network Handles patient data Hospital network Off-the-shelf software PropertyDevice includes the usage of a web/HTTP applications (PID-311) Device exposes remote network services (PID-41) Application-level software is present and running on the device (PID-31) ComponentWeb Application InterfaceTCP AssetPatient Data | No response from manufacturer |
| 2 | Harmony Referral SystemTopcon Healthcare, System, Image Management, Ophthalmic | Exposed to the same EMB3D threatTID-32314 shared attributes | Device typeimaging family SignalFile import Patient or study database Web interface Wired network Remote access Handles patient data Hospital network Off-the-shelf software PropertyDevice includes the usage of a web/HTTP applications (PID-311) Device exposes remote network services (PID-41) Application-level software is present and running on the device (PID-31) ComponentWeb Application InterfaceTCP | No response from manufacturer |
| 3 | NovoPathAI, Digital Pathology Image Viewing And Management Software | Same signals12 shared attributes | Device typeimaging family SignalFile import Patient or study database Web interface Handles patient data Off-the-shelf software PropertyDevice includes the usage of a web/HTTP applications (PID-311) Device exposes remote network services (PID-41) Application-level software is present and running on the device (PID-31) ComponentWeb Application InterfaceTCP AssetPatient Data | No response from manufacturer |
| # | Product | Match | Shared attributes | Manufacturer status |
|---|---|---|---|---|
| 1 | aPROMISE XExini Diagnostics, System, Image Processing, Radiological | 13 shared attributes | Device typeimaging family SignalFile import Patient or study database Web interface Wired network Handles patient data Hospital network PropertyDevice includes the usage of a web/HTTP applications (PID-311) Device exposes remote network services (PID-41) Application-level software is present and running on the device (PID-31) ComponentWeb Application InterfaceTCP AssetPatient Data | No response from manufacturer |
| 2 | Aperio GT 450 DXLeica Biosystems, Whole Slide Imaging System | 11 shared attributes | Device typeimaging family SignalWeb interface Remote access Hospital network Off-the-shelf software PropertyDevice includes the usage of a web/HTTP applications (PID-311) Device exposes remote network services (PID-41) Application-level software is present and running on the device (PID-31) Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations (PID-411) ComponentWeb Application AssetPatient Data | No response from manufacturer |
| 3 | WAVE Clinical PlatformBaxter, Monitor, Physiological, Patient (Without Arrhythmia Detection Or Alarms) | 12 shared attributes | SignalPatient or study database Web interface Wired network Remote access Handles patient data Hospital network PropertyDevice includes the usage of a web/HTTP applications (PID-311) Device exposes remote network services (PID-41) Application-level software is present and running on the device (PID-31) Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations (PID-411) ComponentWeb Application AssetPatient Data | No response from manufacturer |
| 4 | Vscan AirGE HealthCare, System, Imaging, Pulsed Doppler, Ultrasonic | 11 shared attributes | Device typeimaging family SignalWeb interface Remote access Handles patient data Hospital network PropertyDevice includes the usage of a web/HTTP applications (PID-311) Device exposes remote network services (PID-41) Application-level software is present and running on the device (PID-31) Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations (PID-411) ComponentWeb Application AssetPatient Data | No response from manufacturer |
| 5 | ACUSON Sequoia Diagnostic Ultrasound SystemSiemens Healthineers, System, Imaging, Pulsed Doppler, Ultrasonic | 12 shared attributes | Device typeimaging family SignalFile import Patient or study database Wired network Remote access Handles patient data Hospital network PropertyDevice exposes remote network services (PID-41) Application-level software is present and running on the device (PID-31) ComponentStorage InterfaceTCP AssetPatient Data | No response from manufacturer |
| 6 | qERQure.ai, Radiological Computer-Assisted Triage And Notification Software | 11 shared attributes | Device typeimaging family SignalWeb interface Handles patient data Hospital network PropertyDevice includes the usage of a web/HTTP applications (PID-311) Device exposes remote network services (PID-41) Application-level software is present and running on the device (PID-31) Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations (PID-411) ComponentWeb Application InterfaceTCP AssetPatient Data | No response from manufacturer |
| 7 | Universal ViewerGE HealthCare | 11 shared attributes | SignalPatient or study database Web interface Wired network Hospital network Off-the-shelf software PropertyDevice includes the usage of a web/HTTP applications (PID-311) Device exposes remote network services (PID-41) Application-level software is present and running on the device (PID-31) ComponentWeb Application InterfaceTCP AssetPatient Data | No response from manufacturer |
| 8 | Syngo Carbon Space VA20ASiemens Healthineers, System, Image Processing, Radiological | 11 shared attributes | Device typeimaging family SignalWeb interface Handles patient data Hospital network PropertyDevice includes the usage of a web/HTTP applications (PID-311) Device exposes remote network services (PID-41) Application-level software is present and running on the device (PID-31) ComponentWeb Application Storage InterfaceTCP AssetPatient Data | No response from manufacturer |
| 9 | Aperio GT 450 DX; Aperio GT 180 DXLeica Biosystems, Whole Slide Imaging System | 11 shared attributes | Device typeimaging family SignalRemote access Handles patient data Hospital network Off-the-shelf software PropertyDevice includes the usage of a web/HTTP applications (PID-311) Device exposes remote network services (PID-41) Application-level software is present and running on the device (PID-31) Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations (PID-411) ComponentWeb Application AssetPatient Data | No response from manufacturer |
| 10 | Connected OR Hub with Device and Voice ControlStryker, Laparoscope, General & Plastic Surgery | 12 shared attributes | SignalPatient or study database Wired network Remote access Handles patient data Hospital network Off-the-shelf software PropertyDevice exposes remote network services (PID-41) Application-level software is present and running on the device (PID-31) Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations (PID-411) ComponentStorage InterfaceTCP AssetPatient Data | No response from manufacturer |
| 11 | BlueStar RxWelldoc, Calculator, Drug Dose | 11 shared attributes | SignalPatient or study database Web interface Remote access Handles patient data PropertyDevice includes the usage of a web/HTTP applications (PID-311) Device exposes remote network services (PID-41) Application-level software is present and running on the device (PID-31) Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations (PID-411) ComponentWeb Application InterfaceTCP AssetPatient Data | No response from manufacturer |
| 12 | aetherSlidePhilips, Digital Pathology Image Viewing And Management Software | 10 shared attributes | Device typeimaging family SignalFile import Web interface Handles patient data PropertyDevice includes the usage of a web/HTTP applications (PID-311) Device exposes remote network services (PID-41) Application-level software is present and running on the device (PID-31) ComponentWeb Application Storage AssetPatient Data | No response from manufacturer |
| 13 | LUX-Dx II Insertable Cardiac Monitor (M302)Boston Scientific, Recorder, Event, Implantable Cardiac, (With Arrhythmia Detection) | 10 shared attributes | SignalWeb interface Remote access Handles patient data Off-the-shelf software PropertyDevice includes the usage of a web/HTTP applications (PID-311) Device exposes remote network services (PID-41) Application-level software is present and running on the device (PID-31) Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations (PID-411) ComponentWeb Application AssetPatient Data | No response from manufacturer |
| 14 | LUX-Dx II (M302); LUX-Dx II+Boston Scientific, Recorder, Event, Implantable Cardiac, (With Arrhythmia Detection) | 10 shared attributes | SignalWeb interface Remote access Handles patient data Off-the-shelf software PropertyDevice includes the usage of a web/HTTP applications (PID-311) Device exposes remote network services (PID-41) Application-level software is present and running on the device (PID-31) Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations (PID-411) ComponentWeb Application AssetPatient Data | No response from manufacturer |
| 15 | CoroFlow Cardiovascular SystemCoroventis Research, Computer, Diagnostic, Programmable | 11 shared attributes | SignalPatient or study database Wired network Handles patient data Hospital network Off-the-shelf software PropertyDevice exposes remote network services (PID-41) Application-level software is present and running on the device (PID-31) Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations (PID-411) ComponentStorage InterfaceTCP AssetPatient Data | No response from manufacturer |
| 16 | Infinity Gateway SuiteDräger, System, Network And Communication, Physiological Monitors | 11 shared attributes | SignalPatient or study database Wired network Remote access Handles patient data Hospital network Off-the-shelf software PropertyDevice exposes remote network services (PID-41) Application-level software is present and running on the device (PID-31) Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations (PID-411) InterfaceTCP AssetPatient Data | No response from manufacturer |
| 17 | Dose IQ Safety SoftwareBaxter, Infusion Safety Management Software | 9 shared attributes | SignalPatient or study database Web interface Hospital network Off-the-shelf software PropertyDevice includes the usage of a web/HTTP applications (PID-311) Device exposes remote network services (PID-41) Application-level software is present and running on the device (PID-31) ComponentWeb Application InterfaceTCP | No response from manufacturer |
| 18 | Cardiologs Holter PlatformPhilips, Electrocardiograph | 10 shared attributes | SignalFile import Web interface Remote access Handles patient data PropertyDevice exposes remote network services (PID-41) Application-level software is present and running on the device (PID-31) Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations (PID-411) ComponentWeb Application InterfaceTCP AssetPatient Data | No response from manufacturer |
| 19 | IntraSight PlusPhilips, System, Imaging, Pulsed Echo, Ultrasonic | 10 shared attributes | Device typeimaging family SignalFile import Patient or study database Wired network Hospital network PropertyDevice exposes remote network services (PID-41) Application-level software is present and running on the device (PID-31) ComponentStorage InterfaceTCP AssetPatient Data | No response from manufacturer |
| 20 | Heartvue.ProtonHeartVue, Automated Radiological Image Processing Software | 10 shared attributes | SignalFile import Web interface Handles patient data Hospital network PropertyDevice includes the usage of a web/HTTP applications (PID-311) Device exposes remote network services (PID-41) Application-level software is present and running on the device (PID-31) ComponentWeb Application InterfaceTCP AssetPatient Data | No response from manufacturer |
| 21 | qCT LN QuantQure.ai, Automated Radiological Image Processing Software | 9 shared attributes | Device typeimaging family SignalWeb interface Hospital network PropertyDevice includes the usage of a web/HTTP applications (PID-311) Device exposes remote network services (PID-41) Application-level software is present and running on the device (PID-31) ComponentWeb Application InterfaceTCP AssetPatient Data | No response from manufacturer |
| 22 | BD Phoenix Automated Microbiology SystemBD, System, Test, Automated, Antimicrobial Susceptibility, Short Incubation | 9 shared attributes | SignalPatient or study database Web interface Wired network Hospital network PropertyDevice includes the usage of a web/HTTP applications (PID-311) Device exposes remote network services (PID-41) Application-level software is present and running on the device (PID-31) ComponentWeb Application InterfaceTCP | No response from manufacturer |
| 23 | IdentifyVarian, Accelerator, Linear, Medical | 9 shared attributes | SignalFile import Web interface Remote access Handles patient data Hospital network PropertyDevice includes the usage of a web/HTTP applications (PID-311) Device exposes remote network services (PID-41) ComponentWeb Application AssetPatient Data | No response from manufacturer |
| 24 | Versana BalanceGE HealthCare, System, Imaging, Pulsed Doppler, Ultrasonic | 9 shared attributes | Device typeimaging family SignalFile import Wired network Remote access Handles patient data PropertyDevice exposes remote network services (PID-41) Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations (PID-411) ComponentStorage AssetPatient Data | No response from manufacturer |
| 25 | syngo Application SoftwareSiemens Healthineers, Automated Radiological Image Processing Software | 10 shared attributes | Device typeimaging family SignalFile import Patient or study database Wired network Handles patient data PropertyDevice exposes remote network services (PID-41) Application-level software is present and running on the device (PID-31) ComponentStorage InterfaceTCP AssetPatient Data | No response from manufacturer |