Aperio GT 450 DX
Whole Slide Imaging System. Attributes come from Leica Biosystems's own public documentation for this product.
Attributes
Properties (MITRE EMB3D)
PID-31 Application-level software is present and running on the device PID-311 Device includes the usage of a web/HTTP applications PID-312 Device includes programming languages and libraries PID-33 Device includes interactive applications, services, or user interfaces PID-41 Device exposes remote network services PID-411 Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations
Attributes: materials
PHP
Attributes: component types
API Display Framework Generic Application Generic Hardware Library Local Application Local Service Sensor Modules User Interface Web Application
Attributes: assets
Patient Data
Attributes: dataflows
Aperio GT 450 DX scanner to Aperio WebViewer DX (SVS images) Aperio GT 450 DX scanner to Sectra Digital Pathology Module (SVS and DICOM images) Viewing software to Displays (digital slide images)
Matched threat intel
28
Advisories in our coverage that share an attribute with this product. A shared attribute is a lead, not a finding. The status column shows only what Leica Biosystems has said.
| Advisory | Date | Shared | Leica Biosystems status |
|---|---|---|---|
| Path traversal in Thermo Fisher's Torrent Suite lets authenticated users read server files | Oct 15, 2026 | Same property (MITRE EMB3D)PID-311 | No feedback feed from manufacturer |
| A hard-coded VNC password on a bioreactor, base score 9.8 | May 26, 2026 | Same property (MITRE EMB3D)PID-411 | No feedback feed from manufacturer |
| EMS patient-care app reflects unsanitized input into a WebView | Feb 10, 2026 | Same property (MITRE EMB3D)PID-311 | No feedback feed from manufacturer |
| User enumeration on the CareLink Network, found at a conference | Dec 4, 2025 | Same property (MITRE EMB3D)PID-311 | No feedback feed from manufacturer |
| A hospital management backend leaked its own system information | Oct 28, 2025 | Same property (MITRE EMB3D)PID-311 | No feedback feed from manufacturer |
| A low-privilege user can walk past role limits in Synapse Mobility | Aug 21, 2025 | Same property (MITRE EMB3D)PID-311 | No feedback feed from manufacturer |
| Five flaws in Sante PACS Server, and one sends credentials in cleartext | Aug 12, 2025 | Same property (MITRE EMB3D)PID-311 | No feedback feed from manufacturer |
| Pixmeo OsiriX MD crashes on crafted DICOM files and sends web portal credentials in cleartext | May 8, 2025 | Same property (MITRE EMB3D)PID-311 | No feedback feed from manufacturer |
| A patient monitor with a hidden backdoor that phones home | Jan 30, 2025 | Same property (MITRE EMB3D)PID-411 | No feedback feed from manufacturer |
| A 10.0 SQL injection on a patient health portal | Sep 5, 2024 | Same property (MITRE EMB3D)PID-311 | No feedback feed from manufacturer |
| LifePoint Informatics Patient Portal generated lab report PDFs from a URL and a patient ID | Apr 5, 2022 | Same property (MITRE EMB3D)PID-311 | No feedback feed from manufacturer |
| Philips Tasy EMR HTML5 has two SQL injection flaws that expose patient data | Nov 4, 2021 | Same property (MITRE EMB3D)PID-311 | No feedback feed from manufacturer |
| Innokas VC150 vital signs monitor accepts HL7 injection and stored XSS | Jan 7, 2021 | Same property (MITRE EMB3D)PID-311 | No feedback feed from manufacturer |
| GE Healthcare imaging and ultrasound systems expose default service credentials | Dec 8, 2020 | Same property (MITRE EMB3D)PID-411 | No feedback feed from manufacturer |
| Philips Clinical Collaboration Platform 12.2.1 and earlier has five web and authentication flaws | Sep 17, 2020 | Same property (MITRE EMB3D)PID-311 | No feedback feed from manufacturer |
| Philips IntelliVue monitors and PIC iX skip certificate revocation and crash on bad input | Sep 10, 2020 | Same property (MITRE EMB3D)PID-311 | No feedback feed from manufacturer |
| Philips Tasy EMR and WebPortal carry cross-site scripting and information exposure flaws | Apr 30, 2019 | Same property (MITRE EMB3D)PID-311 | No feedback feed from manufacturer |
| Change Healthcare PeerVue Web Server leaks technical details in HTTP error messages | Oct 4, 2018 | Same property (MITRE EMB3D)PID-311 | No feedback feed from manufacturer |
| BeaconMedaes TotalAlert Scroll Medical Air Systems expose stored passwords to unauthenticated users | May 24, 2018 | Same property (MITRE EMB3D)PID-311 | No feedback feed from manufacturer |
| Philips EncoreAnywhere exposes sensitive data in its HTTP headers | May 17, 2018 | Same property (MITRE EMB3D)PID-311 | No feedback feed from manufacturer |
| B. Braun SpaceStation with SpaceCom module has an open redirect in its web server | Mar 23, 2017 | Same property (MITRE EMB3D)PID-311 | No feedback feed from manufacturer |
| Unauthenticated SQL injection into an imaging database, base score 9.8 | Dec 6, 2024 | Exposed to the same EMB3D threatTID-320 | No feedback feed from manufacturer |
| Softneta MedDream PACS allows unauthenticated remote code execution | Sep 5, 2023 | Exposed to the same EMB3D threatTID-324 | No feedback feed from manufacturer |
| BD Synapsys sessions did not expire, risking changes to patient data | May 31, 2022 | Exposed to the same EMB3D threatTID-321 | No feedback feed from manufacturer |
| Philips Gemini PET/CT systems write sensitive data to removable media without access control | Mar 25, 2021 | Exposed to the same EMB3D threatTID-324 | No feedback feed from manufacturer |
| OpenClinic GA advisory lists authentication bypass, file upload and SQL abuse flaws | Jul 2, 2020 | Exposed to the same EMB3D threatTID-319 | No feedback feed from manufacturer |
| Roche Accu-Chek and CoaguChek point of care handhelds expose a weakly protected service interface | Nov 6, 2018 | Exposed to the same EMB3D threatTID-324 | No feedback feed from manufacturer |
| Medtronic 2090 CareLink and 29901 Encore programmers accept updates without verifying their origin | Feb 27, 2018 | Exposed to the same EMB3D threatTID-323 | No feedback feed from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-116 Latent Privileged Access Port TID-211 Device Allows Unauthenticated Firmware Installation TID-213 Faulty FW/SW Update Integrity Verification TID-215 Unencrypted SW/FW Updates TID-221 Authentication Bypass By Message Replay TID-222 Critical System Service May Be Disabled TID-224 Excessive Access via Software Diagnostic Features TID-226 Device leaks security information in logs TID-310 Remotely Accessible Unauthenticated Services TID-311 Default Credentials TID-316 Incorrect Certificate Verification Allows Authentication Bypass TID-317 Predictable Cryptographic Key TID-319 Cross Site Scripting (XSS) TID-320 SQL Injection TID-323 Path Traversal TID-324 HTTP Direct Object Reference TID-327 Out of Bounds Memory Access TID-328 Hardcoded Credentials TID-329 Improper Password Storage TID-401 Undocumented Protocol Features TID-404 Remotely Triggerable Deadlock/DoS TID-405 Network Stack Resource Exhaustion TID-406 Unauthorized Messages or Connections TID-408 Unencrypted Sensitive Data Communication TID-411 Weak/Insecure Cryptographic Protocol
CWE weaknesses
CWE-1188 Insecure Default Initialization of Resource CWE-122 Heap-based Buffer Overflow CWE-125 Out-of-bounds Read CWE-1392 Use of Default Credentials CWE-20 Improper Input Validation CWE-200 Exposure of Sensitive Information to an Unauthorized Actor CWE-276 Incorrect Default Permissions CWE-284 Improper Access Control CWE-294 Authentication Bypass by Capture-replay CWE-319 Cleartext Transmission of Sensitive Information CWE-321 Use of Hard-coded Cryptographic Key CWE-326 Inadequate Encryption Strength CWE-345 Insufficient Verification of Data Authenticity CWE-400 Uncontrolled Resource Consumption CWE-476 NULL Pointer Dereference CWE-494 Download of Code Without Integrity Check CWE-506 Embedded Malicious Code CWE-522 Insufficiently Protected Credentials CWE-639 Authorization Bypass Through User-Controlled Key CWE-787 Out-of-bounds Write CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') CWE-798 Use of Hard-coded Credentials CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') CWE-912 Hidden Functionality CWE-916 Use of Password Hash With Insufficient Computational Effort