Corneal topographer and dry eye analyzer. Attributes come from Topcon Healthcare's own public documentation for this product.
Attributes
Signals
Properties (MITRE EMB3D)
Platform
Windows 10 Enterprise LTSC
Attributes: materials
Windows 10
Attributes: component types
Circuit Board Display Generic Application Local Application Memory Operating System Storage User Interface Wireless Module
Attributes: interface types
Ethernet USB WiFi
Attributes: assets
Report Data Software Code
Attributes: dataflows
CA-800 to Network Printer CA-800 to Network Shared Folder (PDF) CA-800 to USB Media (PDF) CA-800 to USB Printer
Matched threat intel
Top 20 of 23
Advisories in our coverage that share attributes with this product, strongest first: a named product or component, the same device type or lineage, then the most shared attributes. A shared attribute is a lead, not a finding. The status column shows only what Topcon Healthcare has said.
| # | Advisory | Date | Shared | Topcon Healthcare status |
|---|---|---|---|---|
| 1 | Cepheid GeneXpert Xpress 6.4a ships without Windows speculative execution mitigations | Mar 11, 2026 | Same named componentWindows 10 (= 21H2 / 22H2)5 shared attributes: Lab and diagnostics family, Named operating system, Device includes OS/kernel (PID-23), Operating System +1 | No response from manufacturer |
| 2 | Cepheid GeneXpert Dx 6.4a needs Windows 10 update KB5068781 for 32 CVEs | Mar 12, 2026 | Same named componentWindows 10 (= 21H2)5 shared attributes: Lab and diagnostics family, Named operating system, Device includes OS/kernel (PID-23), Operating System +1 | No response from manufacturer |
| 3 | Carestream lists Windows 10 based imaging products as affected by CurveBall CryptoAPI flaw | Jan 17, 2020 | Same named componentWindows 10 (any version)4 shared attributes: Named operating system, Device includes OS/kernel (PID-23), Operating System, Local Application | No response from manufacturer |
| 4 | BD tests Microsoft's Bad Neighbor patch for FACS, Pyxis and Rowa products | Dec 3, 2020 | Same named componentWindows 10 (= 1803)3 shared attributes: Lab and diagnostics family, Named operating system, Operating System | No response from manufacturer |
| 5 | Carestream DirectView and ImageView systems affected by BlueKeep and DejaBlue RDP flaws | May 16, 2019 | Same named componentWindows 10 (= 1607 LTSB)3 shared attributes: Named operating system, Device includes OS/kernel (PID-23), Operating System | No response from manufacturer |
| 6 | Philips lists 26 products running Windows under the CryptoAPI spoofing flaw CVE-2020-0601 | Jan 16, 2020 | Same named componentWindows 10 (= 1803)2 shared attributes: Named operating system, Operating System | No response from manufacturer |
| 7 | Philips lists Capsule Neuron under Windows PEAP denial of service CVE-2023-21701 | Mar 29, 2023 | Same named componentWindows 10 (range 10.0.0)1 shared attribute: Wireless connectivity | No response from manufacturer |
| 8 | Capsule Technologies SmartLinx Neuron 2 kiosk escapes to admin with a USB keyboard | Jul 14, 2020 | Same property (MITRE EMB3D)PID-237 shared attributes: USB port, Device includes external peripheral interconnects (e.g., USB, Serial) (PID-14), Device includes OS/kernel (PID-23), Operating System +3 | No response from manufacturer |
| 9 | Philips IntelliVue Information Center iX B.02 can be knocked offline by repeated UDP requests | Aug 21, 2018 | Same property (MITRE EMB3D)PID-233 shared attributes: Wired network, Named operating system, Operating System | No response from manufacturer |
| 10 | Canon Medical flags FragAttacks Wi-Fi flaws in wireless FPD and ultrasound wireless options | Jul 4, 2022 | Same platformWindows 10 IoT Enterprise3 shared attributes: Wireless connectivity, Wireless Module, WiFi | No response from manufacturer |
| 11 | BD Alaris 8015 PC unit exposes stored Wi-Fi credentials on its removable flash card | Jan 17, 2017 | 7 shared attributesRemovable media, Wireless connectivity, Wireless Module, Storage +3 | No response from manufacturer |
| 12 | Roche Accu-Chek and CoaguChek point of care handhelds expose a weakly protected service interface | Nov 6, 2018 | 7 shared attributesLab and diagnostics family, Analyzer, Wired network, Wireless connectivity +3 | No response from manufacturer |
| 13 | BD Alaris PC Unit can drop off hospital Wi-Fi through a Linux kernel flaw | Jun 18, 2020 | 6 shared attributesNamed operating system, Wireless connectivity, Device includes OS/kernel (PID-23), Operating System +2 | No response from manufacturer |
| 14 | BD FACSChorus workstations leave USB, BIOS and PCIe open and store admin secrets in plaintext | Nov 27, 2023 | 6 shared attributesLab and diagnostics family, Named operating system, USB port, Patient or study database +2 | No response from manufacturer |
| 15 | BD FACSLyric workstations on Windows 10 expose an administrative account | Jan 29, 2019 | 6 shared attributesLab and diagnostics family, Analyzer, Named operating system, Device includes OS/kernel (PID-23) +2 | No response from manufacturer |
| 16 | Beckman Coulter maps PrintNightmare print spooler flaws across its lab instrument line | Aug 13, 2021 | 5 shared attributesLab and diagnostics family, Analyzer, Named operating system, Wired network +1 | No response from manufacturer |
| 17 | Karl Storz AIDA systems potentially affected by Windows Wi-Fi driver flaw CVE-2024-30078 | Jul 16, 2024 | 5 shared attributesWireless connectivity, Named operating system, Operating System, Wireless Module +1 | No response from manufacturer |
| 18 | Cepheid GeneXpert touchscreens on Cepheid OS 2.1 need three Windows 10 kernel updates | Sep 30, 2025 | 5 shared attributesLab and diagnostics family, Named operating system, Device includes OS/kernel (PID-23), Operating System +1 | No response from manufacturer |
| 19 | DePuy Synthes tells Brainlab KICK users to verify MS17-010 against WannaCry and Petya | Jul 18, 2017 | 5 shared attributesNamed operating system, Wired network, Device includes OS/kernel (PID-23), Generic Application +1 | No response from manufacturer |
| 20 | Beckman Coulter issues per-instrument guidance as Petya ransomware spreads through EternalBlue | Jun 28, 2017 | 5 shared attributesLab and diagnostics family, Analyzer, Wired network, Local Application +1 | No response from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-103 Microarchitectural Side Channels TID-107 Unauthorized Direct Memory Access (DMA) TID-108 ROM/NVRAM Data Extraction or Modification TID-111 Untrusted External Storage TID-202 Exploitable System Network Stack Component TID-204 Untrusted Programs Can Access Privileged OS Functions TID-205 Existing OS Tools Maliciously Used for Device Manipulation TID-210 Device Vulnerabilities Unpatchable TID-213 Faulty FW/SW Update Integrity Verification TID-219 OS/Kernel Privilege Escalation TID-221 Authentication Bypass By Message Replay TID-222 Critical System Service May Be Disabled TID-226 Device leaks security information in logs TID-310 Remotely Accessible Unauthenticated Services TID-311 Default Credentials TID-314 Passwords Can Be Guessed Using Brute-Force Attempts TID-316 Incorrect Certificate Verification Allows Authentication Bypass TID-317 Predictable Cryptographic Key TID-324 HTTP Direct Object Reference TID-328 Hardcoded Credentials TID-329 Improper Password Storage TID-404 Remotely Triggerable Deadlock/DoS TID-405 Network Stack Resource Exhaustion TID-406 Unauthorized Messages or Connections
CWE weaknesses
CWE-1104 Use of Unmaintained Third Party Components CWE-1188 Insecure Default Initialization of Resource CWE-1329 Reliance on Component That is Not Updateable CWE-1395 Dependency on Vulnerable Third-Party Component CWE-20 Improper Input Validation CWE-200 Exposure of Sensitive Information to an Unauthorized Actor CWE-276 Incorrect Default Permissions CWE-284 Improper Access Control CWE-294 Authentication Bypass by Capture-replay CWE-321 Use of Hard-coded Cryptographic Key CWE-400 Uncontrolled Resource Consumption CWE-427 Uncontrolled Search Path Element CWE-476 NULL Pointer Dereference CWE-522 Insufficiently Protected Credentials CWE-639 Authorization Bypass Through User-Controlled Key CWE-916 Use of Password Hash With Insufficient Computational Effort