Central Stations
Central nursing station monitor. Attributes come from Nihon Kohden's own public documentation for this product.
Attributes
Signals
Properties (MITRE EMB3D)
PID-31 Application-level software is present and running on the device PID-311 Device includes the usage of a web/HTTP applications PID-33 Device includes interactive applications, services, or user interfaces PID-34 Device stores logs of application events and information PID-41 Device exposes remote network services PID-411 Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations
Attributes: component types
API Display Generic Application Local Application Local Service Mobile Application Storage User Interface Web Application
Attributes: interface types
Unknown Wireless
Attributes: assets
Log Data Patient Data Report Data Software Configuration
Attributes: dataflows
Bedside Monitors to Central Station (waveforms, numerics, alarms) Central Station to Browser via NetKonnect (real-time and historical monitoring data) Central Station to Mobile Devices via ViTrac Life Scope network to Clinical Information Systems via HL7 Gateway Telemetry Receivers to Central Station
Matched threat intel
Top 20 of 25
Advisories in our coverage that share attributes with this product, strongest first: a named product or component, the same device type or lineage, then the most shared attributes. A shared attribute is a lead, not a finding. The status column shows only what Nihon Kohden has said.
| # | Advisory | Date | Shared | Nihon Kohden status |
|---|---|---|---|---|
| 1 | Philips IntelliVue monitors and PIC iX skip certificate revocation and crash on bad input | Sep 10, 2020 | Same property (MITRE EMB3D)PID-31115 shared attributes: Patient monitoring family, Monitor, Central, Hospital network +11 | No response from manufacturer |
| 2 | Missing authentication lets an attacker rewrite a cardiac wearable | May 28, 2026 | Same property (MITRE EMB3D)PID-41113 shared attributes: Monitor, Wireless connectivity, Handles patient data, Mobile app +9 | No response from manufacturer |
| 3 | Unauthenticated SQL injection into an imaging database, base score 9.8 | Dec 6, 2024 | Exposed to the same EMB3D threatTID-32012 shared attributes: Patient or study database, Handles patient data, Wired network, Remote access +8 | No response from manufacturer |
| 4 | A 10.0 SQL injection on a patient health portal | Sep 5, 2024 | Same property (MITRE EMB3D)PID-31110 shared attributes: Patient or study database, Handles patient data, Web interface, Remote access +6 | No response from manufacturer |
| 5 | GE CARESCAPE, ApexPro and CIC monitoring systems carry hard-coded SMB credentials and five more critical flaws | Jan 23, 2020 | 13 shared attributesPatient monitoring family, Monitor, Central, Wired network +9 | No response from manufacturer |
| 6 | A null-pointer dereference can take down a central patient monitor | Oct 23, 2025 | 14 shared attributesPatient monitoring family, Central, Monitor, Hospital network +10 | No response from manufacturer |
| 7 | Unrestricted file upload on a PACS points straight at code execution | Apr 10, 2025 | 13 shared attributesPatient or study database, Web interface, Wired network, Remote access +9 | No response from manufacturer |
| 8 | User enumeration on the CareLink Network, found at a conference | Dec 4, 2025 | 10 shared attributesPatient monitoring family, Monitor, Web interface, Remote access +6 | No response from manufacturer |
| 9 | Innokas VC150 vital signs monitor accepts HL7 injection and stored XSS | Jan 7, 2021 | 8 shared attributesPatient monitoring family, Monitor, HL7 or FHIR integration, Web interface +4 | No response from manufacturer |
| 10 | A hospital management backend leaked its own system information | Oct 28, 2025 | 10 shared attributesHandles patient data, Remote access, Web interface, Patient or study database +6 | No response from manufacturer |
| 11 | Philips IntelliBridge Enterprise writes plaintext EMR credentials into its transaction logs | Jun 11, 2020 | 6 shared attributesWeb interface, Hospital network, Device stores logs of application events and information (PID-34), Device includes the usage of a web/HTTP applications (PID-311) +2 | No response from manufacturer |
| 12 | Philips PIC iX and Efficia CM Series carry a hard-coded key and weak crypto | Nov 18, 2021 | 8 shared attributesPatient monitoring family, Central, Monitor, Handles patient data +4 | No response from manufacturer |
| 13 | Weak API input validation opens a monitoring platform to denial of service | Jul 17, 2025 | 8 shared attributesPatient monitoring family, Monitor, Remote access, Web interface +4 | No response from manufacturer |
| 14 | Dräger Infinity Delta monitors allow kiosk escape, reboot loops and unauthenticated log access | Jan 22, 2019 | 7 shared attributesPatient monitoring family, Monitor, Wired network, Hospital network +3 | No response from manufacturer |
| 15 | BeaconMedaes TotalAlert Scroll Medical Air Systems expose stored passwords to unauthenticated users | May 24, 2018 | 6 shared attributesWeb interface, Wired network, Hospital network, Device includes the usage of a web/HTTP applications (PID-311) +2 | No response from manufacturer |
| 16 | Hillrom Welch Allyn Connex and Spot devices carry chained out-of-bounds write and read flaws | Jun 1, 2021 | 7 shared attributesPatient monitoring family, Monitor, Central, Hospital network +3 | No response from manufacturer |
| 17 | Philips IntelliVue Information Center iX B.02 can be knocked offline by repeated UDP requests | Aug 21, 2018 | 6 shared attributesPatient monitoring family, Central, Monitor, Wired network +2 | No response from manufacturer |
| 18 | B. Braun SpaceStation with SpaceCom module has an open redirect in its web server | Mar 23, 2017 | 5 shared attributesStation, Web interface, Hospital network, Device includes the usage of a web/HTTP applications (PID-311) +1 | No response from manufacturer |
| 19 | Philips PIC iX 4.x listed as affected by two Windows DHCP vulnerabilities | Jun 22, 2026 | 5 shared attributesPatient monitoring family, Monitor, Central, Wired network +1 | No response from manufacturer |
| 20 | Change Healthcare PeerVue Web Server leaks technical details in HTTP error messages | Oct 4, 2018 | 4 shared attributesWeb interface, Device includes the usage of a web/HTTP applications (PID-311), Web Application, Log Data | No response from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-202 Exploitable System Network Stack Component TID-204 Untrusted Programs Can Access Privileged OS Functions TID-205 Existing OS Tools Maliciously Used for Device Manipulation TID-210 Device Vulnerabilities Unpatchable TID-213 Faulty FW/SW Update Integrity Verification TID-219 OS/Kernel Privilege Escalation TID-221 Authentication Bypass By Message Replay TID-222 Critical System Service May Be Disabled TID-226 Device leaks security information in logs TID-305 Program Executes Dangerous System Calls TID-306 Sandboxed Environments Escaped TID-310 Remotely Accessible Unauthenticated Services TID-311 Default Credentials TID-316 Incorrect Certificate Verification Allows Authentication Bypass TID-317 Predictable Cryptographic Key TID-319 Cross Site Scripting (XSS) TID-320 SQL Injection TID-323 Path Traversal TID-324 HTTP Direct Object Reference TID-327 Out of Bounds Memory Access TID-328 Hardcoded Credentials TID-329 Improper Password Storage TID-401 Undocumented Protocol Features TID-404 Remotely Triggerable Deadlock/DoS TID-405 Network Stack Resource Exhaustion TID-406 Unauthorized Messages or Connections TID-407 Missing Message Replay Protection TID-408 Unencrypted Sensitive Data Communication TID-411 Weak/Insecure Cryptographic Protocol
CWE weaknesses
CWE-1104 Use of Unmaintained Third Party Components CWE-1188 Insecure Default Initialization of Resource CWE-122 Heap-based Buffer Overflow CWE-125 Out-of-bounds Read CWE-1329 Reliance on Component That is Not Updateable CWE-1392 Use of Default Credentials CWE-1395 Dependency on Vulnerable Third-Party Component CWE-20 Improper Input Validation CWE-200 Exposure of Sensitive Information to an Unauthorized Actor CWE-22 Improper Limitation of a Pathname to a Restricted Directory CWE-276 Incorrect Default Permissions CWE-284 Improper Access Control CWE-290 Authentication Bypass by Spoofing CWE-294 Authentication Bypass by Capture-replay CWE-306 Missing Authentication for Critical Function CWE-319 Cleartext Transmission of Sensitive Information CWE-321 Use of Hard-coded Cryptographic Key CWE-326 Inadequate Encryption Strength CWE-400 Uncontrolled Resource Consumption CWE-427 Uncontrolled Search Path Element CWE-434 Unrestricted Upload of File with Dangerous Type CWE-476 NULL Pointer Dereference CWE-522 Insufficiently Protected Credentials CWE-639 Authorization Bypass Through User-Controlled Key CWE-787 Out-of-bounds Write CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') CWE-798 Use of Hard-coded Credentials CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') CWE-916 Use of Password Hash With Insufficient Computational Effort