CloudHRV
Heart rate variability diagnostic system. Attributes come from Inmedix's own public documentation for this product.
Attributes
Signals
Properties (MITRE EMB3D)
PID-31 Application-level software is present and running on the device PID-311 Device includes the usage of a web/HTTP applications PID-33 Device includes interactive applications, services, or user interfaces PID-332 Device includes authenticated services PID-41 Device exposes remote network services PID-411 Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations
Platform
iOS companion app: iOS app
Attributes: component types
API Cloud Service Generic Application Generic Hardware Local Application Local Service Mobile Application Sensor Modules User Interface Web Application
Attributes: interface types
WiFi
Attributes: assets
Patient Data Report Data Sensor Data User Data
Attributes: dataflows
ECG sensor to Tablet (CloudHRV app) Management Cloud web interface to Inmedix Cloud (clinic user administration and assessment results) Tablet to Inmedix Cloud over Wi-Fi (ECG data)
Matched threat intel
Top 20 of 65
Advisories in our coverage that share attributes with this product, strongest first: a named product or component, the same device type or lineage, then the most shared attributes. A shared attribute is a lead, not a finding. The status column shows only what Inmedix has said.
| # | Advisory | Date | Shared | Inmedix status |
|---|---|---|---|---|
| 1 | Mira’s cloud login accepted any password and returned a session token | Aug 11, 2026 | Same property (MITRE EMB3D)PID-41115 shared attributes: Handles patient data, Cloud connectivity, User accounts, Mobile app +11 | No response from manufacturer |
| 2 | A low-privilege user can walk past role limits in Synapse Mobility | Aug 21, 2025 | Same property (MITRE EMB3D)PID-31112 shared attributes: Handles patient data, Web interface, User accounts, Cloud connectivity +8 | No response from manufacturer |
| 3 | A 10.0 SQL injection on a patient health portal | Sep 5, 2024 | Same property (MITRE EMB3D)PID-31111 shared attributes: Patient or study database, Handles patient data, Cloud connectivity, Web interface +7 | No response from manufacturer |
| 4 | Dario Health glucose monitoring app and servers exposed cross-user health data | Feb 27, 2025 | Same property (MITRE EMB3D)PID-31110 shared attributes: Cloud connectivity, Mobile app, Handles patient data, Web interface +6 | No response from manufacturer |
| 5 | User enumeration on the CareLink Network, found at a conference | Dec 4, 2025 | Same property (MITRE EMB3D)PID-3119 shared attributes: Cloud connectivity, User accounts, Web interface, Handles patient data +5 | No response from manufacturer |
| 6 | Unauthenticated SQL injection into an imaging database, base score 9.8 | Dec 6, 2024 | Exposed to the same EMB3D threatTID-32011 shared attributes: Patient or study database, Handles patient data, Web interface, User accounts +7 | No response from manufacturer |
| 7 | LifePoint Informatics Patient Portal generated lab report PDFs from a URL and a patient ID | Apr 5, 2022 | Same property (MITRE EMB3D)PID-3118 shared attributes: Lab and diagnostics family, Web interface, Handles patient data, Cloud connectivity +4 | No response from manufacturer |
| 8 | Path traversal in Thermo Fisher's Torrent Suite lets authenticated users read server files | Oct 15, 2026 | Same property (MITRE EMB3D)PID-3329 shared attributes: Lab and diagnostics family, Device includes the usage of a web/HTTP applications (PID-311), Device includes authenticated services (PID-332), Application-level software is present and running on the device (PID-31) +5 | No response from manufacturer |
| 9 | A legacy cardiology system, end-of-service since 2014, recalled for security | Jun 10, 2025 | Same property (MITRE EMB3D)PID-4119 shared attributes: Patient or study database, Handles patient data, User accounts, Off-the-shelf software +5 | No response from manufacturer |
| 10 | Philips Tasy EMR and WebPortal carry cross-site scripting and information exposure flaws | Apr 30, 2019 | Same property (MITRE EMB3D)PID-3117 shared attributes: Web interface, Handles patient data, User accounts, Device includes the usage of a web/HTTP applications (PID-311) +3 | No response from manufacturer |
| 11 | Philips DoseWise Portal hard-codes its database credentials and stores logins in clear text | Aug 17, 2017 | Same property (MITRE EMB3D)PID-3327 shared attributes: Patient or study database, User accounts, Web interface, Handles patient data +3 | No response from manufacturer |
| 12 | Philips Tasy EMR HTML5 has two SQL injection flaws that expose patient data | Nov 4, 2021 | Same property (MITRE EMB3D)PID-3326 shared attributes: Patient or study database, Handles patient data, User accounts, Web interface +2 | No response from manufacturer |
| 13 | Philips Clinical Collaboration Platform 12.2.1 and earlier has five web and authentication flaws | Sep 17, 2020 | Same property (MITRE EMB3D)PID-3114 shared attributes: Web interface, User accounts, Device includes the usage of a web/HTTP applications (PID-311), Web Application | No response from manufacturer |
| 14 | BeaconMedaes TotalAlert Scroll Medical Air Systems expose stored passwords to unauthenticated users | May 24, 2018 | Same property (MITRE EMB3D)PID-3114 shared attributes: User accounts, Web interface, Device includes the usage of a web/HTTP applications (PID-311), Web Application | No response from manufacturer |
| 15 | BD Synapsys sessions did not expire, risking changes to patient data | May 31, 2022 | Same property (MITRE EMB3D)PID-3326 shared attributes: User accounts, Handles patient data, Patient or study database, Device includes authenticated services (PID-332) +2 | No response from manufacturer |
| 16 | Philips EncoreAnywhere exposes sensitive data in its HTTP headers | May 17, 2018 | Same property (MITRE EMB3D)PID-3114 shared attributes: Cloud connectivity, Web interface, Device includes the usage of a web/HTTP applications (PID-311), Web Application | No response from manufacturer |
| 17 | Empty passwords and cleartext storage in a home cardiac monitor | Jul 24, 2025 | Exposed to the same EMB3D threatTID-3117 shared attributes: Handles patient data, User accounts, Wireless connectivity, Patient or study database +3 | No response from manufacturer |
| 18 | B. Braun SpaceStation with SpaceCom module has an open redirect in its web server | Mar 23, 2017 | Same property (MITRE EMB3D)PID-3114 shared attributes: Web interface, Device includes the usage of a web/HTTP applications (PID-311), Web Application, Generic Hardware | No response from manufacturer |
| 19 | Change Healthcare PeerVue Web Server leaks technical details in HTTP error messages | Oct 4, 2018 | Same property (MITRE EMB3D)PID-3113 shared attributes: Web interface, Device includes the usage of a web/HTTP applications (PID-311), Web Application | No response from manufacturer |
| 20 | Apollo Pharmacy APG-01 BT glucose meter sends readings over BLE in cleartext | Jun 18, 2026 | Same property (MITRE EMB3D)PID-4115 shared attributes: Wireless connectivity, Handles patient data, Mobile app, Mobile Application +1 | No response from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-108 ROM/NVRAM Data Extraction or Modification TID-111 Untrusted External Storage TID-202 Exploitable System Network Stack Component TID-204 Untrusted Programs Can Access Privileged OS Functions TID-205 Existing OS Tools Maliciously Used for Device Manipulation TID-210 Device Vulnerabilities Unpatchable TID-219 OS/Kernel Privilege Escalation TID-221 Authentication Bypass By Message Replay TID-222 Critical System Service May Be Disabled TID-226 Device leaks security information in logs TID-304 Manipulate Runtime Environment TID-310 Remotely Accessible Unauthenticated Services TID-311 Default Credentials TID-313 Unauthenticated Session Changes Credential TID-314 Passwords Can Be Guessed Using Brute-Force Attempts TID-316 Incorrect Certificate Verification Allows Authentication Bypass TID-317 Predictable Cryptographic Key TID-318 Insecure Cryptographic Implementation TID-319 Cross Site Scripting (XSS) TID-320 SQL Injection TID-323 Path Traversal TID-324 HTTP Direct Object Reference TID-326 Insecure Deserialization TID-327 Out of Bounds Memory Access TID-328 Hardcoded Credentials TID-329 Improper Password Storage TID-401 Undocumented Protocol Features TID-404 Remotely Triggerable Deadlock/DoS TID-405 Network Stack Resource Exhaustion TID-406 Unauthorized Messages or Connections TID-408 Unencrypted Sensitive Data Communication TID-411 Weak/Insecure Cryptographic Protocol
CWE weaknesses
CWE-1104 Use of Unmaintained Third Party Components CWE-1188 Insecure Default Initialization of Resource CWE-1329 Reliance on Component That is Not Updateable CWE-1390 Weak Authentication CWE-1392 Use of Default Credentials CWE-1395 Dependency on Vulnerable Third-Party Component CWE-20 Improper Input Validation CWE-200 Exposure of Sensitive Information to an Unauthorized Actor CWE-276 Incorrect Default Permissions CWE-284 Improper Access Control CWE-287 Improper Authentication CWE-294 Authentication Bypass by Capture-replay CWE-306 Missing Authentication for Critical Function CWE-319 Cleartext Transmission of Sensitive Information CWE-321 Use of Hard-coded Cryptographic Key CWE-326 Inadequate Encryption Strength CWE-400 Uncontrolled Resource Consumption CWE-427 Uncontrolled Search Path Element CWE-476 NULL Pointer Dereference CWE-502 Deserialization of Untrusted Data CWE-522 Insufficiently Protected Credentials CWE-639 Authorization Bypass Through User-Controlled Key CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') CWE-798 Use of Hard-coded Credentials CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') CWE-916 Use of Password Hash With Insufficient Computational Effort