LATITUDE Programming System
Cardiac rhythm management programmer. Attributes come from Boston Scientific's own public documentation for this product.
Attributes
Signals
Properties (MITRE EMB3D)
PID-27 Device includes support for firmware/software updates PID-31 Application-level software is present and running on the device PID-33 Device includes interactive applications, services, or user interfaces PID-41 Device exposes remote network services PID-411 Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations
Attributes: component types
API Battery Display Firmware Generic Application Generic Hardware Local Application Local Service User Interface
Attributes: interface types
Bluetooth
Attributes: assets
Log Data Patient Data Report Data Sensor Data Software Update
Attributes: dataflows
Programmer to EMR System via Bluetooth using LATITUDE Link (patient data) Programmer to Implantable Pulse Generator (interrogation and programming) Programmer to Remote Users via Heart Connect System (shared programmer screen)
Matched threat intel
19
Advisories in our coverage that share attributes with this product, strongest first: a named product or component, the same device type or lineage, then the most shared attributes. A shared attribute is a lead, not a finding. The status column shows only what Boston Scientific has said.
| # | Advisory | Date | Shared | Boston Scientific status |
|---|---|---|---|---|
| 1 | MicroDicom DICOM Viewer 2024.03 fails to validate its update server certificate | Feb 6, 2025 | Same property (MITRE EMB3D)PID-274 shared attributes: Field-updatable firmware, Device includes support for firmware/software updates (PID-27), Local Application, Software Update | No response from manufacturer |
| 2 | Baxter PrismaFlex and PrisMax send treatment data to EMR systems without encryption or authentication | Jun 18, 2020 | Same property (MITRE EMB3D)PID-4115 shared attributes: Hospital network, Therapy delivery, Generic Application, Generic Hardware +1 | No response from manufacturer |
| 3 | Missing authentication lets an attacker rewrite a cardiac wearable | May 28, 2026 | 13 shared attributesCardiology and implants family, Cardiac, Wireless connectivity, Handles patient data +9 | No response from manufacturer |
| 4 | Medtronic MyCareLink Smart 25000 reader allows Bluetooth authentication bypass and unsigned firmware | Dec 10, 2020 | 10 shared attributesCardiology and implants family, Cardiac, Wireless connectivity, Field-updatable firmware +6 | No response from manufacturer |
| 5 | Abbott Accent, Anthem, Assurity and Allure pacemakers get firmware fix for RF authentication bypass | Aug 29, 2017 | 11 shared attributesCardiology and implants family, Wireless connectivity, Therapy delivery, Field-updatable firmware +7 | No response from manufacturer |
| 6 | Abbott ICDs and CRT-Ds allow RF authentication bypass and battery drain | Apr 17, 2018 | 9 shared attributesCardiology and implants family, Wireless connectivity, Therapy delivery, Field-updatable firmware +5 | No response from manufacturer |
| 7 | Boston Scientific ZOOM LATITUDE PRM Model 3120 accepts unsigned software from USB and can be re-regioned | Sep 30, 2021 | 8 shared attributesCardiology and implants family, Cardiac, Programmer, Field-updatable firmware +4 | No response from manufacturer |
| 8 | Medtronic patches Bluetooth In-Office flaws between BlueSync pacemakers and SmartSync Device Manager | Sep 10, 2020 | 8 shared attributesCardiology and implants family, Cardiac, Programm, Wireless connectivity +4 | No response from manufacturer |
| 9 | Philips IntelliSpace Cardiovascular and Xcelera store credentials in cleartext | Nov 14, 2017 | 7 shared attributesCardiology and implants family, Cardiac, Handles patient data, Hospital network +3 | No response from manufacturer |
| 10 | Hillrom Welch Allyn ELI resting electrocardiographs contain hard-coded passwords | Jun 16, 2022 | 5 shared attributesCardiology and implants family, Physiological waveform processing, Hospital network, Firmware +1 | No response from manufacturer |
| 11 | Fresenius lists Conox anesthesia monitor as affected by BLUFFS Bluetooth flaw | Apr 10, 2024 | 7 shared attributesWireless connectivity, Physiological waveform processing, Handles patient data, Firmware +3 | No response from manufacturer |
| 12 | Biosense Webster releases free Security Service Pack for CARTO 3 Version 7.2 | May 31, 2024 | 4 shared attributesCardiology and implants family, Cardiac, Device includes support for firmware/software updates (PID-27), Software Update | No response from manufacturer |
| 13 | Boston Scientific ZOOM LATITUDE PRM uses a hard-coded key and leaves patient data unencrypted | Oct 19, 2017 | 6 shared attributesCardiology and implants family, Cardiac, Programmer, Handles patient data +2 | No response from manufacturer |
| 14 | CARTO 3 Versions 6 and 7.1 run vulnerable Print Spooler, fixed in Security Service Pack 4 | Nov 23, 2022 | 4 shared attributesCardiology and implants family, Cardiac, Local Service, Software Update | No response from manufacturer |
| 15 | Biosense Webster CARTO 3 V6 SP3 applies Windows patches and antivirus updates | Jan 8, 2021 | 4 shared attributesCardiology and implants family, Cardiac, Local Application, Software Update | No response from manufacturer |
| 16 | CARTO 3 V4 systems lack Windows patches; Biosense Webster offers free V6 upgrade | Apr 9, 2018 | 4 shared attributesCardiology and implants family, Cardiac, Local Application, Software Update | No response from manufacturer |
| 17 | Medtronic CareLink 9790, 2090 and Encore 29901 programmers store patient data unencrypted | Dec 13, 2018 | 5 shared attributesCardiology and implants family, Programmer, Handles patient data, Patient Data +1 | No response from manufacturer |
| 18 | Biosense Webster ships Security Service Packs for CARTO 3 Versions 6 and 7.1 | Jul 24, 2023 | 3 shared attributesCardiology and implants family, Cardiac, Device includes support for firmware/software updates (PID-27) | No response from manufacturer |
| 19 | Philips discloses vulnerabilities in PageWriter TC10 to TC70 cardiographs | Aug 16, 2018 | 4 shared attributesCardiology and implants family, Physiological waveform processing, Handles patient data, Hospital network | No response from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-210 Device Vulnerabilities Unpatchable TID-211 Device Allows Unauthenticated Firmware Installation TID-213 Faulty FW/SW Update Integrity Verification TID-215 Unencrypted SW/FW Updates TID-219 OS/Kernel Privilege Escalation TID-221 Authentication Bypass By Message Replay TID-222 Critical System Service May Be Disabled TID-224 Excessive Access via Software Diagnostic Features TID-310 Remotely Accessible Unauthenticated Services TID-311 Default Credentials TID-316 Incorrect Certificate Verification Allows Authentication Bypass TID-317 Predictable Cryptographic Key TID-327 Out of Bounds Memory Access TID-328 Hardcoded Credentials TID-329 Improper Password Storage TID-404 Remotely Triggerable Deadlock/DoS TID-405 Network Stack Resource Exhaustion TID-406 Unauthorized Messages or Connections TID-407 Missing Message Replay Protection TID-408 Unencrypted Sensitive Data Communication TID-411 Weak/Insecure Cryptographic Protocol
CWE weaknesses
CWE-1104 Use of Unmaintained Third Party Components CWE-1329 Reliance on Component That is Not Updateable CWE-1392 Use of Default Credentials CWE-20 Improper Input Validation CWE-290 Authentication Bypass by Spoofing CWE-294 Authentication Bypass by Capture-replay CWE-306 Missing Authentication for Critical Function CWE-319 Cleartext Transmission of Sensitive Information CWE-321 Use of Hard-coded Cryptographic Key CWE-326 Inadequate Encryption Strength CWE-345 Insufficient Verification of Data Authenticity CWE-400 Uncontrolled Resource Consumption CWE-476 NULL Pointer Dereference CWE-494 Download of Code Without Integrity Check CWE-522 Insufficiently Protected Credentials CWE-798 Use of Hard-coded Credentials CWE-916 Use of Password Hash With Insufficient Computational Effort