Diagnostic Cardiology Suite ECG
PC-based ECG and spirometry software. Attributes come from Baxter's own public documentation for this product.
Attributes
Signals
Properties (MITRE EMB3D)
PID-123 Device includes ROM, VRAM, or removable Storage PID-23 Device includes OS/kernel PID-2322 Device deploys an access enforcement/privilege mechanism PID-31 Application-level software is present and running on the device PID-33 Device includes interactive applications, services, or user interfaces PID-332 Device includes authenticated services PID-34 Device stores logs of application events and information PID-41 Device exposes remote network services PID-411 Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations
Platform
Linux Windows
Attributes: component types
API Generic Application Local Application Local Service Operating System Sensor Modules Storage User Interface Wireless Module
Attributes: interface types
TCP USB Wireless
Attributes: assets
Calibration Data Credentials Log Data Patient Data Report Data Sensor Data Software Code Software Configuration
Attributes: dataflows
Diagnostic Cardiology Suite to EMR (patient data and final report) Diagnostic Cardiology Suite to EMR (report with discrete data) Diagnostic Cardiology Suite to PACS or ECG management system via DICOM EMR to Diagnostic Cardiology Suite (exam launch) USB media to PC (software installation) Wireless acquisition module to Diagnostic Cardiology Suite (ECG data)
Matched threat intel
Top 20 of 122
Advisories in our coverage that share attributes with this product, strongest first: a named product or component, the same device type or lineage, then the most shared attributes. A shared attribute is a lead, not a finding. The status column shows only what Baxter has said.
| # | Advisory | Date | Shared | Baxter status |
|---|---|---|---|---|
| 1 | Philips PageWriter TC cardiographs expose a hard-coded superuser password and unchecked input | Aug 16, 2018 | Exposed to the same EMB3D threatTID-3299 shared attributes: Cardiology and implants family, User accounts, Hospital network, Device includes OS/kernel (PID-23) +5 | No response from manufacturer |
| 2 | BD Pyxis products may still run on shared default operating system credentials | May 31, 2022 | Same property (MITRE EMB3D)PID-239 shared attributes: User accounts, Handles patient data, Hospital network, Device includes OS/kernel (PID-23) +5 | No response from manufacturer |
| 3 | Login credentials exposed on the workstation in a GE imaging viewer | Mar 16, 2026 | Exposed to the same EMB3D threatTID-3299 shared attributes: User accounts, Hospital network, Remote access, Handles patient data +5 | No response from manufacturer |
| 4 | Philips IntelliSpace Cardiovascular and Xcelera servers allow privilege escalation through writable executable folders | Aug 14, 2018 | Same property (MITRE EMB3D)PID-23226 shared attributes: Cardiology and implants family, Cardiology, User accounts, Role-based access +2 | No response from manufacturer |
| 5 | BD Alaris 8000 PC unit stores wireless network credentials unencrypted in flash memory | Jan 17, 2017 | Same property (MITRE EMB3D)PID-1236 shared attributes: Wireless connectivity, Hospital network, Storage, Wireless Module +2 | No response from manufacturer |
| 6 | Capsule Technologies SmartLinx Neuron 2 kiosk escapes to admin with a USB keyboard | Jul 14, 2020 | Same property (MITRE EMB3D)PID-236 shared attributes: USB port, Hospital network, Device includes OS/kernel (PID-23), Operating System +2 | No response from manufacturer |
| 7 | Philips IntelliVue Information Center iX B.02 can be knocked offline by repeated UDP requests | Aug 21, 2018 | Same property (MITRE EMB3D)PID-234 shared attributes: Hospital network, Named operating system, Device exposes remote network services (PID-41), Operating System | No response from manufacturer |
| 8 | Thermo Fisher Xcalibur and Foundation driver packages allow local privilege escalation | Jan 22, 2025 | Same platformWindows3 shared attributes: Named operating system, Local Application, Credentials | No response from manufacturer |
| 9 | Canon Medical flags FragAttacks Wi-Fi flaws in wireless FPD and ultrasound wireless options | Jul 4, 2022 | Same platformWindows 10 IoT Enterprise3 shared attributes: Diagnostic, Wireless connectivity, Wireless Module | No response from manufacturer |
| 10 | Hillrom Welch Allyn Connex and Spot devices carry chained out-of-bounds write and read flaws | Jun 1, 2021 | Same platformLinux3 shared attributes: Hospital network, Local Application, Local Service | No response from manufacturer |
| 11 | A hard-coded VNC password on a bioreactor, base score 9.8 | May 26, 2026 | 15 shared attributesRemote access, User accounts, Wireless connectivity, Field-updatable firmware +11 | No response from manufacturer |
| 12 | A legacy cardiology system, end-of-service since 2014, recalled for security | Jun 10, 2025 | 13 shared attributesCardiology and implants family, Cardiology, Handles patient data, User accounts +9 | No response from manufacturer |
| 13 | A low-privilege user can walk past role limits in Synapse Mobility | Aug 21, 2025 | 13 shared attributesHandles patient data, User accounts, Role-based access, Remote access +9 | No response from manufacturer |
| 14 | Missing authentication lets an attacker rewrite a cardiac wearable | May 28, 2026 | 14 shared attributesCardiology and implants family, Wireless connectivity, Handles patient data, User accounts +10 | No response from manufacturer |
| 15 | B. Braun SpaceCom and Battery Pack SP with Wi-Fi carry 11 flaws from XSS to unsigned firmware | Oct 22, 2020 | 10 shared attributesWireless connectivity, Field-updatable firmware, Named operating system, User accounts +6 | No response from manufacturer |
| 16 | Default credentials across a line of diagnostic instruments | Dec 17, 2024 | 11 shared attributesDiagnostic, Handles patient data, Remote access, User accounts +7 | No response from manufacturer |
| 17 | BD Alaris 8015 PC unit exposes stored Wi-Fi credentials on its removable flash card | Jan 17, 2017 | 9 shared attributesWireless connectivity, Hospital network, Device includes ROM, VRAM, or removable Storage (PID-123), Wireless Module +5 | No response from manufacturer |
| 18 | Contec CMS8000 patient monitors crash on a UDP broadcast and accept unauthenticated USB firmware | Sep 1, 2022 | 11 shared attributesUSB port, Wireless connectivity, Handles patient data, Field-updatable firmware +7 | No response from manufacturer |
| 19 | Philips lists more than 30 products in DejaBlue Remote Desktop advisory | Aug 15, 2019 | 11 shared attributesCardiology and implants family, Cardiology, Diagnostic, Named operating system +7 | No response from manufacturer |
| 20 | Baxter ExactaMix compounders carry hard-coded admin credentials and send orders in clear text | Jun 18, 2020 | 12 shared attributesUser accounts, USB port, Handles patient data, Device exposes remote network services (PID-41) +8 | No response from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-103 Microarchitectural Side Channels TID-108 ROM/NVRAM Data Extraction or Modification TID-111 Untrusted External Storage TID-115 Firmware/Data Extraction via Hardware Interface TID-116 Latent Privileged Access Port TID-119 Latent Hardware Debug Port Allows Memory/Code Manipulation TID-202 Exploitable System Network Stack Component TID-204 Untrusted Programs Can Access Privileged OS Functions TID-205 Existing OS Tools Maliciously Used for Device Manipulation TID-210 Device Vulnerabilities Unpatchable TID-211 Device Allows Unauthenticated Firmware Installation TID-213 Faulty FW/SW Update Integrity Verification TID-215 Unencrypted SW/FW Updates TID-219 OS/Kernel Privilege Escalation TID-221 Authentication Bypass By Message Replay TID-222 Critical System Service May Be Disabled TID-224 Excessive Access via Software Diagnostic Features TID-226 Device leaks security information in logs TID-301 Applications Binaries Modified TID-303 Excessive Trust in Offboard Management/IDE Software TID-305 Program Executes Dangerous System Calls TID-310 Remotely Accessible Unauthenticated Services TID-311 Default Credentials TID-313 Unauthenticated Session Changes Credential TID-314 Passwords Can Be Guessed Using Brute-Force Attempts TID-316 Incorrect Certificate Verification Allows Authentication Bypass TID-317 Predictable Cryptographic Key TID-318 Insecure Cryptographic Implementation TID-319 Cross Site Scripting (XSS) TID-320 SQL Injection TID-321 HTTP Application Session Hijacking TID-323 Path Traversal TID-324 HTTP Direct Object Reference TID-326 Insecure Deserialization TID-327 Out of Bounds Memory Access TID-328 Hardcoded Credentials TID-329 Improper Password Storage TID-404 Remotely Triggerable Deadlock/DoS TID-405 Network Stack Resource Exhaustion TID-406 Unauthorized Messages or Connections TID-407 Missing Message Replay Protection TID-408 Unencrypted Sensitive Data Communication TID-411 Weak/Insecure Cryptographic Protocol
CWE weaknesses
CWE-1104 Use of Unmaintained Third Party Components CWE-1188 Insecure Default Initialization of Resource CWE-1191 On-Chip Debug and Test Interface With Improper Access Control CWE-122 Heap-based Buffer Overflow CWE-125 Out-of-bounds Read CWE-1313 Hardware Allows Activation of Test or Debug Logic at Runtime CWE-1329 Reliance on Component That is Not Updateable CWE-1390 Weak Authentication CWE-1392 Use of Default Credentials CWE-1395 Dependency on Vulnerable Third-Party Component CWE-20 Improper Input Validation CWE-200 Exposure of Sensitive Information to an Unauthorized Actor CWE-22 Improper Limitation of a Pathname to a Restricted Directory CWE-276 Incorrect Default Permissions CWE-284 Improper Access Control CWE-287 Improper Authentication CWE-290 Authentication Bypass by Spoofing CWE-294 Authentication Bypass by Capture-replay CWE-306 Missing Authentication for Critical Function CWE-319 Cleartext Transmission of Sensitive Information CWE-321 Use of Hard-coded Cryptographic Key CWE-326 Inadequate Encryption Strength CWE-345 Insufficient Verification of Data Authenticity CWE-400 Uncontrolled Resource Consumption CWE-427 Uncontrolled Search Path Element CWE-434 Unrestricted Upload of File with Dangerous Type CWE-476 NULL Pointer Dereference CWE-494 Download of Code Without Integrity Check CWE-502 Deserialization of Untrusted Data CWE-522 Insufficiently Protected Credentials CWE-639 Authorization Bypass Through User-Controlled Key CWE-787 Out-of-bounds Write CWE-798 Use of Hard-coded Credentials CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') CWE-916 Use of Password Hash With Insufficient Computational Effort