Cloud clinical image and data management platform. Attributes come from Topcon Healthcare's own public documentation for this product.
Attributes
Signals
Properties (MITRE EMB3D)
PID-23 Device includes OS/kernel PID-2322 Device deploys an access enforcement/privilege mechanism PID-311 Device includes the usage of a web/HTTP applications PID-312 Device includes programming languages and libraries PID-332 Device includes authenticated services PID-41 Device exposes remote network services PID-411 Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations PID-4113 Device includes cryptographic functions for sensitive data, such as encryption or authentication
Platform
Linux Windows Web browser: Microsoft Edge Web browser: Mozilla Firefox Java
Attributes: materials
Mirth connect Windows Server
Attributes: component types
API Cloud Application Framework Generic Application Generic Hardware Library Local Application Local Service Operating System Storage Web Application
Attributes: interface types
TCP Virtual
Attributes: assets
Patient Data Report Data
Attributes: dataflows
Care Team to Device via Harmony remote refraction (real-time device control) Device to CSG via tablet and adapter cable (printer files) Device to Harmony via DICOM (result) EMR to Harmony via HL7 ORM (order) EMR to Harmony via Mirth Connect (ADT patient info) Harmony to Customer PC/Server (data migration of folder structure and SQL database) Harmony to Device via DICOM (patient demographics) Harmony to EMR via HL7 ORU (result) Harmony to Export (images as JPG or original format, multiple as JPG zip) Non-DICOM Device to Harmony via exported image folder (image plus patient demographics) Offline Device to Harmony via network drive (manual upload) Patient chart (EMR) to Harmony via encrypted weblink with patient ID Practice Management System to Harmony via HL7 ADT (patient master list)
Matched threat intel
Top 20 of 236
Advisories in our coverage that share attributes with this product, strongest first: a named product or component, the same device type or lineage, then the most shared attributes. A shared attribute is a lead, not a finding. The status column shows only what Topcon Healthcare has said.
| # | Advisory | Date | Shared | Topcon Healthcare status |
|---|---|---|---|---|
| 1 | Three High Severity Flaws Hit NextGen Healthcare's Mirth Connect | Sep 10, 2026 | Same named componentMirth Connect (<= 4.7.1)18 shared attributes: Handles patient data, Off-the-shelf software, Remote access, User accounts +14 | No response from manufacturer |
| 2 | Philips IntelliSpace Portal 7.0 and 8.0 carry 35 vulnerabilities, led by remote code execution | Feb 27, 2018 | Same named componentWindows Server (= 2008 R2 SP1)12 shared attributes: Imaging family, Platform, Named operating system, Remote access +8 | No response from manufacturer |
| 3 | Philips’ July advisory run is a lesson in where device risk actually lives | Aug 11, 2026 | Same named componentWindows Server (range 10.0.20348.0)11 shared attributes: Imaging family, Off-the-shelf software, Named operating system, DICOM or image parsing +7 | No response from manufacturer |
| 4 | Philips names PACS and imaging servers in Zerologon CVE-2020-1472 advisory | Sep 14, 2020 | Same named componentWindows Server (= 1903)9 shared attributes: Imaging family, Platform, Data, Named operating system +5 | No response from manufacturer |
| 5 | Baxter lists five Hillrom, Welch Allyn and connectivity products exposed to Mirth Connect CVE-2023-43208 | Jan 31, 2024 | Same named componentMirth Connect (< 4.4.1)6 shared attributes: Imaging family, Data, Platform, Off-the-shelf software +2 | No response from manufacturer |
| 6 | Philips lists more than 30 products in DejaBlue Remote Desktop advisory | Aug 15, 2019 | Same named componentWindows Server (= 1803)10 shared attributes: Imaging family, Image, Named operating system, Remote access +6 | No response from manufacturer |
| 7 | BD Pyxis keeps access for expired Active Directory accounts when joined to a hospital domain | Sep 5, 2019 | Same named componentWindows Server (range 4.4)9 shared attributes: User accounts, Hospital network, Handles patient data, Named operating system +5 | No response from manufacturer |
| 8 | Leica Biosystems Aperio and CEREBRO products affected by Mirth Connect vulnerabilities | Jan 26, 2024 | Same named componentMirth Connect (<= 4.4.1)7 shared attributes: Imaging family, Image, Off-the-shelf software, HL7 or FHIR integration +3 | No response from manufacturer |
| 9 | Philips lists PIC iX and Focal Point under exploited WSUS flaw CVE-2025-59287 | Oct 27, 2025 | Same named componentWindows Server (= 2012)7 shared attributes: Imaging family, Clinical, Named operating system, Hospital network +3 | No response from manufacturer |
| 10 | Philips lists HeartStart, IntelliVue and IntelliSpace products as Windows Server 2012 reaches end of life | Oct 10, 2023 | Same named componentMirth Connect (any version)6 shared attributes: Imaging family, Data, Clinical, Named operating system +2 | No response from manufacturer |
| 11 | Philips lists Vue PACS and Vue RIS under Mirth Connect flaws CVE-2023-37679 and CVE-2023-43208 | Nov 3, 2023 | Same named componentMirth Connect (< 4.4.1)5 shared attributes: Imaging family, Off-the-shelf software, HL7 or FHIR integration, TCP +1 | No response from manufacturer |
| 12 | Spacelabs Xhibit Telemetry Receiver is exposed to the BlueKeep RDP flaw | Feb 18, 2020 | Same named componentWindows Server (= 2003)9 shared attributes: Named operating system, Remote access, Off-the-shelf software, Hospital network +5 | No response from manufacturer |
| 13 | Philips names ten product lines in Windows Task Scheduler CVE-2024-49039 notice | Nov 18, 2024 | Same named componentWindows Server (= 2019)7 shared attributes: Imaging family, Clinical, Data, Named operating system +3 | No response from manufacturer |
| 14 | Medtronic lists CareLink EHR integration and Vital Sync as affected by Mirth Connect remote code execution flaws | Nov 30, 2023 | Same named componentMirth Connect (< 4.4.1)6 shared attributes: Platform, Off-the-shelf software, HL7 or FHIR integration, Hospital network +2 | No response from manufacturer |
| 15 | Siemens Healthineers lists imaging and lab products affected by DejaBlue Remote Desktop flaws | Sep 10, 2019 | Same named componentWindows Server (= 1803)8 shared attributes: Imaging family, Data, Named operating system, Hospital network +4 | No response from manufacturer |
| 16 | bioMérieux says some products include vulnerable Mirth Connect, CVE-2023-43208 | Apr 3, 2024 | Same named componentMirth Connect (<= 4.4.0)4 shared attributes: Data, Off-the-shelf software, HL7 or FHIR integration, Mirth Connect | No response from manufacturer |
| 17 | BD lists FocalPoint, Kiestra and BD MAX in scope for three Remote Desktop flaws | Apr 3, 2020 | Same named componentWindows Server (= 2012)7 shared attributes: Imaging family, Data, Clinical, Remote access +3 | No response from manufacturer |
| 18 | Philips lists PACS, PIC iX and IntelliBridge products as exposed to the SIGRED Windows DNS flaw | Jul 15, 2020 | Same named componentWindows Server (= 1903)6 shared attributes: Imaging family, Data, Named operating system, Off-the-shelf software +2 | No response from manufacturer |
| 19 | Philips reviews 52 products running Windows 7 and Server 2008 R2 at end of support | Jan 14, 2020 | Same named componentWindows Server (= 2008 R2)4 shared attributes: Imaging family, Named operating system, Operating System, Windows Server | No response from manufacturer |
| 20 | Beckman Coulter validates Microsoft's BlueKeep patch across its Windows systems | Jun 28, 2019 | Same named componentWindows Server (= 2003)5 shared attributes: Named operating system, Operating System, Local Service, TCP +1 | No response from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-103 Microarchitectural Side Channels TID-111 Untrusted External Storage TID-116 Latent Privileged Access Port TID-202 Exploitable System Network Stack Component TID-204 Untrusted Programs Can Access Privileged OS Functions TID-205 Existing OS Tools Maliciously Used for Device Manipulation TID-210 Device Vulnerabilities Unpatchable TID-211 Device Allows Unauthenticated Firmware Installation TID-213 Faulty FW/SW Update Integrity Verification TID-215 Unencrypted SW/FW Updates TID-216 Firmware Update Rollbacks Allowed TID-217 Remotely Initiated Updates Can Cause DoS TID-219 OS/Kernel Privilege Escalation TID-221 Authentication Bypass By Message Replay TID-222 Critical System Service May Be Disabled TID-224 Excessive Access via Software Diagnostic Features TID-225 Logs can be manipulated on the device TID-226 Device leaks security information in logs TID-301 Applications Binaries Modified TID-303 Excessive Trust in Offboard Management/IDE Software TID-304 Manipulate Runtime Environment TID-305 Program Executes Dangerous System Calls TID-310 Remotely Accessible Unauthenticated Services TID-311 Default Credentials TID-313 Unauthenticated Session Changes Credential TID-314 Passwords Can Be Guessed Using Brute-Force Attempts TID-316 Incorrect Certificate Verification Allows Authentication Bypass TID-317 Predictable Cryptographic Key TID-318 Insecure Cryptographic Implementation TID-319 Cross Site Scripting (XSS) TID-320 SQL Injection TID-323 Path Traversal TID-324 HTTP Direct Object Reference TID-326 Insecure Deserialization TID-327 Out of Bounds Memory Access TID-328 Hardcoded Credentials TID-329 Improper Password Storage TID-401 Undocumented Protocol Features TID-404 Remotely Triggerable Deadlock/DoS TID-405 Network Stack Resource Exhaustion TID-406 Unauthorized Messages or Connections TID-408 Unencrypted Sensitive Data Communication TID-411 Weak/Insecure Cryptographic Protocol
CWE weaknesses
CWE-1104 Use of Unmaintained Third Party Components CWE-1188 Insecure Default Initialization of Resource CWE-122 Heap-based Buffer Overflow CWE-125 Out-of-bounds Read CWE-1329 Reliance on Component That is Not Updateable CWE-1390 Weak Authentication CWE-1392 Use of Default Credentials CWE-1395 Dependency on Vulnerable Third-Party Component CWE-20 Improper Input Validation CWE-200 Exposure of Sensitive Information to an Unauthorized Actor CWE-22 Improper Limitation of a Pathname to a Restricted Directory CWE-276 Incorrect Default Permissions CWE-284 Improper Access Control CWE-287 Improper Authentication CWE-294 Authentication Bypass by Capture-replay CWE-306 Missing Authentication for Critical Function CWE-319 Cleartext Transmission of Sensitive Information CWE-321 Use of Hard-coded Cryptographic Key CWE-326 Inadequate Encryption Strength CWE-345 Insufficient Verification of Data Authenticity CWE-353 Missing Support for Integrity Check CWE-400 Uncontrolled Resource Consumption CWE-427 Uncontrolled Search Path Element CWE-434 Unrestricted Upload of File with Dangerous Type CWE-476 NULL Pointer Dereference CWE-494 Download of Code Without Integrity Check CWE-502 Deserialization of Untrusted Data CWE-506 Embedded Malicious Code CWE-522 Insufficiently Protected Credentials CWE-639 Authorization Bypass Through User-Controlled Key CWE-787 Out-of-bounds Write CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') CWE-798 Use of Hard-coded Credentials CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') CWE-912 Hidden Functionality CWE-916 Use of Password Hash With Insufficient Computational Effort