Accu-Chek Guide Solo diabetes manager blood glucose monitoring system
System, Test, Blood Glucose, Over The Counter. Attributes come from Roche's own public documentation for this product.
Attributes
Properties (MITRE EMB3D)
PID-12 Device includes Memory/Storage (external to CPU) PID-14 Device includes external peripheral interconnects (e.g., USB, Serial) PID-28 Device stores logs of system events and information PID-31 Application-level software is present and running on the device PID-33 Device includes interactive applications, services, or user interfaces PID-41 Device exposes remote network services PID-411 Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations
Attributes: component types
API Circuit Board Generic Application Local Application Local Service Memory Operating System Storage User Interface
Attributes: interface types
USB Wireless
Matched threat intel
27
Advisories in our coverage that share an attribute with this product. A shared attribute is a lead, not a finding. The status column shows only what Roche has said.
| Advisory | Date | Shared | Roche status |
|---|---|---|---|
| Mira’s cloud login accepted any password and returned a session token | Aug 11, 2026 | Same property (MITRE EMB3D)PID-411 | No feedback feed from manufacturer |
| Missing authentication lets an attacker rewrite a cardiac wearable | May 28, 2026 | Same property (MITRE EMB3D)PID-411 | No feedback feed from manufacturer |
| A hard-coded VNC password on a bioreactor, base score 9.8 | May 26, 2026 | Same property (MITRE EMB3D)PID-411 | No feedback feed from manufacturer |
| A hospital management backend leaked its own system information | Oct 28, 2025 | Same property (MITRE EMB3D)PID-411 | No feedback feed from manufacturer |
| Missing authentication on a DNA sequencer control plane | Oct 21, 2025 | Same property (MITRE EMB3D)PID-411 | No feedback feed from manufacturer |
| A legacy cardiology system, end-of-service since 2014, recalled for security | Jun 10, 2025 | Same property (MITRE EMB3D)PID-411 | No feedback feed from manufacturer |
| Two maximum-severity flaws in a ventilation system | Nov 14, 2024 | Same property (MITRE EMB3D)PID-14 | No feedback feed from manufacturer |
| A 10.0 SQL injection on a patient health portal | Sep 5, 2024 | Same property (MITRE EMB3D)PID-411 | No feedback feed from manufacturer |
| BD BodyGuard infusion pumps can be reconfigured through the RS-232 port | Dec 1, 2022 | Same property (MITRE EMB3D)PID-14 | No feedback feed from manufacturer |
| Boston Scientific ZOOM LATITUDE PRM Model 3120 accepts unsigned software from USB and can be re-regioned | Sep 30, 2021 | Same property (MITRE EMB3D)PID-14 | No feedback feed from manufacturer |
| GE Healthcare imaging and ultrasound systems expose default service credentials | Dec 8, 2020 | Same property (MITRE EMB3D)PID-411 | No feedback feed from manufacturer |
| Capsule Technologies SmartLinx Neuron 2 kiosk escapes to admin with a USB keyboard | Jul 14, 2020 | Same property (MITRE EMB3D)PID-14 | No feedback feed from manufacturer |
| GE Aestiva and Aespire anesthesia devices can have alarms silenced through unsecured terminal servers | Jul 9, 2019 | Same property (MITRE EMB3D)PID-14 | No feedback feed from manufacturer |
| Path traversal in Thermo Fisher's Torrent Suite lets authenticated users read server files | Oct 15, 2026 | Exposed to the same EMB3D threatTID-226 | No feedback feed from manufacturer |
| User enumeration on the CareLink Network, found at a conference | Dec 4, 2025 | Exposed to the same EMB3D threatTID-226 | No feedback feed from manufacturer |
| A low-privilege user can walk past role limits in Synapse Mobility | Aug 21, 2025 | Exposed to the same EMB3D threatTID-226 | No feedback feed from manufacturer |
| Empty passwords and cleartext storage in a home cardiac monitor | Jul 24, 2025 | Exposed to the same EMB3D threatTID-111 | No feedback feed from manufacturer |
| Dario Health glucose monitoring app and servers exposed cross-user health data | Feb 27, 2025 | Exposed to the same EMB3D threatTID-226 | No feedback feed from manufacturer |
| Softneta MedDream PACS allows unauthenticated remote code execution | Sep 5, 2023 | Exposed to the same EMB3D threatTID-226 | No feedback feed from manufacturer |
| BD Synapsys sessions did not expire, risking changes to patient data | May 31, 2022 | Exposed to the same EMB3D threatTID-226 | No feedback feed from manufacturer |
| LifePoint Informatics Patient Portal generated lab report PDFs from a URL and a patient ID | Apr 5, 2022 | Exposed to the same EMB3D threatTID-226 | No feedback feed from manufacturer |
| Philips Gemini PET/CT systems write sensitive data to removable media without access control | Mar 25, 2021 | Exposed to the same EMB3D threatTID-226 | No feedback feed from manufacturer |
| Philips DreamMapper 2.24 and earlier write attacker-useful details to log files | Jul 30, 2020 | Exposed to the same EMB3D threatTID-226 | No feedback feed from manufacturer |
| OpenClinic GA advisory lists authentication bypass, file upload and SQL abuse flaws | Jul 2, 2020 | Exposed to the same EMB3D threatTID-226 | No feedback feed from manufacturer |
| Philips IntelliBridge Enterprise writes plaintext EMR credentials into its transaction logs | Jun 11, 2020 | Exposed to the same EMB3D threatTID-226 | No feedback feed from manufacturer |
| Roche Accu-Chek and CoaguChek point of care handhelds expose a weakly protected service interface | Nov 6, 2018 | Exposed to the same EMB3D threatTID-226 | No feedback feed from manufacturer |
| Change Healthcare PeerVue Web Server leaks technical details in HTTP error messages | Oct 4, 2018 | Exposed to the same EMB3D threatTID-226 | No feedback feed from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-111 Untrusted External Storage TID-115 Firmware/Data Extraction via Hardware Interface TID-116 Latent Privileged Access Port TID-119 Latent Hardware Debug Port Allows Memory/Code Manipulation TID-204 Untrusted Programs Can Access Privileged OS Functions TID-205 Existing OS Tools Maliciously Used for Device Manipulation TID-210 Device Vulnerabilities Unpatchable TID-211 Device Allows Unauthenticated Firmware Installation TID-213 Faulty FW/SW Update Integrity Verification TID-215 Unencrypted SW/FW Updates TID-219 OS/Kernel Privilege Escalation TID-221 Authentication Bypass By Message Replay TID-222 Critical System Service May Be Disabled TID-226 Device leaks security information in logs TID-310 Remotely Accessible Unauthenticated Services TID-311 Default Credentials TID-313 Unauthenticated Session Changes Credential TID-314 Passwords Can Be Guessed Using Brute-Force Attempts TID-316 Incorrect Certificate Verification Allows Authentication Bypass TID-317 Predictable Cryptographic Key TID-319 Cross Site Scripting (XSS) TID-320 SQL Injection TID-323 Path Traversal TID-324 HTTP Direct Object Reference TID-326 Insecure Deserialization TID-328 Hardcoded Credentials TID-329 Improper Password Storage TID-401 Undocumented Protocol Features TID-404 Remotely Triggerable Deadlock/DoS TID-406 Unauthorized Messages or Connections TID-407 Missing Message Replay Protection TID-408 Unencrypted Sensitive Data Communication
CWE weaknesses
CWE-1104 Use of Unmaintained Third Party Components CWE-1188 Insecure Default Initialization of Resource CWE-1191 On-Chip Debug and Test Interface With Improper Access Control CWE-1313 Hardware Allows Activation of Test or Debug Logic at Runtime CWE-1329 Reliance on Component That is Not Updateable CWE-1390 Weak Authentication CWE-1392 Use of Default Credentials CWE-200 Exposure of Sensitive Information to an Unauthorized Actor CWE-276 Incorrect Default Permissions CWE-284 Improper Access Control CWE-287 Improper Authentication CWE-290 Authentication Bypass by Spoofing CWE-294 Authentication Bypass by Capture-replay CWE-306 Missing Authentication for Critical Function CWE-321 Use of Hard-coded Cryptographic Key CWE-345 Insufficient Verification of Data Authenticity CWE-427 Uncontrolled Search Path Element CWE-494 Download of Code Without Integrity Check CWE-502 Deserialization of Untrusted Data CWE-522 Insufficiently Protected Credentials CWE-639 Authorization Bypass Through User-Controlled Key CWE-798 Use of Hard-coded Credentials CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') CWE-916 Use of Password Hash With Insufficient Computational Effort