Data Insights and Remote Support
Analyzer performance-monitoring digital service. Attributes come from Radiometer's own public documentation for this product.
Attributes
Properties (MITRE EMB3D)
PID-27 Device includes support for firmware/software updates PID-275 Device includes remotely-initiated firmware/software updates PID-28 Device stores logs of system events and information PID-311 Device includes the usage of a web/HTTP applications PID-41 Device exposes remote network services PID-411 Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations PID-4113 Device includes cryptographic functions for sensitive data, such as encryption or authentication
Attributes: component types
API Cloud Service Firmware Library Local Service Operating System Web Application
Attributes: interface types
TCP TLS
Attributes: assets
Credentials Log Data Software Update Telemetry Data
Attributes: dataflows
Analyzer to Connected Digital Service (real-time analyzer status and performance data, outbound only over SSL/TLS) Connected Digital Service to Customer Web Browser Dashboard (real-time analyzer data) Customer to Microsoft Azure AD (authentication for portal access) Field Service Engineer to Analyzer via remote connection (remote troubleshooting and remote software update)
Matched threat intel
Top 20 of 72
Advisories in our coverage that share attributes with this product, strongest first: a named product or component, the same device type or lineage, then the most shared attributes. A shared attribute is a lead, not a finding. The status column shows only what Radiometer has said.
| # | Advisory | Date | Shared | Radiometer status |
|---|---|---|---|---|
| 1 | Change Healthcare PeerVue Web Server leaks technical details in HTTP error messages | Oct 4, 2018 | Same property (MITRE EMB3D)PID-3115 shared attributes: Web interface, Device includes the usage of a web/HTTP applications (PID-311), Web Application, TCP +1 | No response from manufacturer |
| 2 | B. Braun SpaceStation with SpaceCom module has an open redirect in its web server | Mar 23, 2017 | Same property (MITRE EMB3D)PID-3114 shared attributes: Web interface, Device includes the usage of a web/HTTP applications (PID-311), Web Application, TCP | No response from manufacturer |
| 3 | Mira’s cloud login accepted any password and returned a session token | Aug 11, 2026 | 12 shared attributesPatient monitoring family, Monitor, Cloud connectivity, Remote access +8 | No response from manufacturer |
| 4 | B. Braun SpaceCom and Battery Pack SP with Wi-Fi carry 11 flaws from XSS to unsigned firmware | Oct 22, 2020 | 10 shared attributesWeb interface, Field-updatable firmware, Device includes the usage of a web/HTTP applications (PID-311), Device includes support for firmware/software updates (PID-27) +6 | No response from manufacturer |
| 5 | Citrix patches two critical NetScaler zero days after Dutch hospitals shut systems down | Sep 27, 2026 | 11 shared attributesRemote, Device exposes remote network services (PID-41), Device includes the usage of a web/HTTP applications (PID-311), Device stores logs of system events and information (PID-28) +7 | No response from manufacturer |
| 6 | User enumeration on the CareLink Network, found at a conference | Dec 4, 2025 | 10 shared attributesPatient monitoring family, Remote, Monitor, Cloud connectivity +6 | No response from manufacturer |
| 7 | Fresenius Kabi Agilia Connect infusion accessories expose unauthenticated endpoints and weak TLS | Dec 21, 2021 | 9 shared attributesWeb interface, Device includes the usage of a web/HTTP applications (PID-311), Web Application, API +5 | No response from manufacturer |
| 8 | GE CARESCAPE, ApexPro and CIC monitoring systems carry hard-coded SMB credentials and five more critical flaws | Jan 23, 2020 | 10 shared attributesPatient monitoring family, Monitor, Remote access, Web interface +6 | No response from manufacturer |
| 9 | St. Jude Medical Merlin@home transmitters do not verify the Merlin.net endpoint | Jan 9, 2017 | 9 shared attributesRemote, Monitor, Cloud connectivity, Remote access +5 | No response from manufacturer |
| 10 | Dario Health glucose monitoring app and servers exposed cross-user health data | Feb 27, 2025 | 9 shared attributesMonitor, Data, Cloud connectivity, Web interface +5 | No response from manufacturer |
| 11 | Ypsomed mylife App and Cloud encrypted traffic with hard-coded secrets and fixed IVs | Jul 15, 2021 | 8 shared attributesData, Service, Cloud connectivity, Device includes cryptographic functions for sensitive data, such as encryption or authentication (PID-4113) +4 | No response from manufacturer |
| 12 | BridgeLink 26.9.0 closes the Mirth Connect flaws CISA flagged, plus eight inherited CVEs | Oct 1, 2026 | 9 shared attributesDevice exposes remote network services (PID-41), Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations (PID-411), Device includes support for firmware/software updates (PID-27), Device includes cryptographic functions for sensitive data, such as encryption or authentication (PID-4113) +5 | No response from manufacturer |
| 13 | Silex modules in GE MobileLink allow unauthenticated setting changes and command injection | May 8, 2018 | 8 shared attributesWeb interface, Device includes the usage of a web/HTTP applications (PID-311), Device includes support for firmware/software updates (PID-27), Operating System +4 | No response from manufacturer |
| 14 | Philips IntelliVue monitors and PIC iX skip certificate revocation and crash on bad input | Sep 10, 2020 | 7 shared attributesPatient monitoring family, Monitor, Web interface, Device includes cryptographic functions for sensitive data, such as encryption or authentication (PID-4113) +3 | No response from manufacturer |
| 15 | Medtronic 2090 CareLink and 29901 Encore programmers accept updates without verifying their origin | Feb 27, 2018 | 7 shared attributesField-updatable firmware, Cloud connectivity, Device includes support for firmware/software updates (PID-27), Cloud Service +3 | No response from manufacturer |
| 16 | Roche Accu-Chek and CoaguChek point of care handhelds expose a weakly protected service interface | Nov 6, 2018 | 8 shared attributesAnalyzer, Field-updatable firmware, Device exposes remote network services (PID-41), Device includes support for firmware/software updates (PID-27) +4 | No response from manufacturer |
| 17 | BD Alaris Gateway Workstation accepts malicious files during firmware update | Jun 13, 2019 | 7 shared attributesField-updatable firmware, Web interface, Device includes the usage of a web/HTTP applications (PID-311), Firmware +3 | No response from manufacturer |
| 18 | Medtronic MyCareLink monitors expose a debug port with a hard-coded OS password | Jun 28, 2018 | 6 shared attributesMonitor, Field-updatable firmware, Device includes remotely-initiated firmware/software updates (PID-275), Operating System +2 | No response from manufacturer |
| 19 | Philips reports no product impact from Next.js flaw CVE-2026-75604 | Sep 4, 2026 | 8 shared attributesCloud connectivity, Remote access, Web interface, Device includes the usage of a web/HTTP applications (PID-311) +4 | No response from manufacturer |
| 20 | ZOLL Defibrillator Dashboard lets non-admin users upload files that run commands | Jun 10, 2021 | 6 shared attributesWeb interface, Device includes the usage of a web/HTTP applications (PID-311), Device includes cryptographic functions for sensitive data, such as encryption or authentication (PID-4113), Web Application +2 | No response from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-115 Firmware/Data Extraction via Hardware Interface TID-116 Latent Privileged Access Port TID-119 Latent Hardware Debug Port Allows Memory/Code Manipulation TID-202 Exploitable System Network Stack Component TID-204 Untrusted Programs Can Access Privileged OS Functions TID-205 Existing OS Tools Maliciously Used for Device Manipulation TID-210 Device Vulnerabilities Unpatchable TID-211 Device Allows Unauthenticated Firmware Installation TID-213 Faulty FW/SW Update Integrity Verification TID-215 Unencrypted SW/FW Updates TID-219 OS/Kernel Privilege Escalation TID-221 Authentication Bypass By Message Replay TID-222 Critical System Service May Be Disabled TID-224 Excessive Access via Software Diagnostic Features TID-225 Logs can be manipulated on the device TID-226 Device leaks security information in logs TID-304 Manipulate Runtime Environment TID-305 Program Executes Dangerous System Calls TID-310 Remotely Accessible Unauthenticated Services TID-311 Default Credentials TID-313 Unauthenticated Session Changes Credential TID-314 Passwords Can Be Guessed Using Brute-Force Attempts TID-316 Incorrect Certificate Verification Allows Authentication Bypass TID-317 Predictable Cryptographic Key TID-318 Insecure Cryptographic Implementation TID-319 Cross Site Scripting (XSS) TID-320 SQL Injection TID-321 HTTP Application Session Hijacking TID-323 Path Traversal TID-324 HTTP Direct Object Reference TID-326 Insecure Deserialization TID-327 Out of Bounds Memory Access TID-328 Hardcoded Credentials TID-329 Improper Password Storage TID-401 Undocumented Protocol Features TID-404 Remotely Triggerable Deadlock/DoS TID-405 Network Stack Resource Exhaustion TID-406 Unauthorized Messages or Connections TID-408 Unencrypted Sensitive Data Communication TID-411 Weak/Insecure Cryptographic Protocol
CWE weaknesses
CWE-1104 Use of Unmaintained Third Party Components CWE-1188 Insecure Default Initialization of Resource CWE-1191 On-Chip Debug and Test Interface With Improper Access Control CWE-122 Heap-based Buffer Overflow CWE-125 Out-of-bounds Read CWE-1313 Hardware Allows Activation of Test or Debug Logic at Runtime CWE-1329 Reliance on Component That is Not Updateable CWE-1390 Weak Authentication CWE-1392 Use of Default Credentials CWE-1395 Dependency on Vulnerable Third-Party Component CWE-20 Improper Input Validation CWE-200 Exposure of Sensitive Information to an Unauthorized Actor CWE-22 Improper Limitation of a Pathname to a Restricted Directory CWE-276 Incorrect Default Permissions CWE-284 Improper Access Control CWE-287 Improper Authentication CWE-294 Authentication Bypass by Capture-replay CWE-306 Missing Authentication for Critical Function CWE-319 Cleartext Transmission of Sensitive Information CWE-321 Use of Hard-coded Cryptographic Key CWE-326 Inadequate Encryption Strength CWE-345 Insufficient Verification of Data Authenticity CWE-400 Uncontrolled Resource Consumption CWE-427 Uncontrolled Search Path Element CWE-434 Unrestricted Upload of File with Dangerous Type CWE-476 NULL Pointer Dereference CWE-494 Download of Code Without Integrity Check CWE-522 Insufficiently Protected Credentials CWE-639 Authorization Bypass Through User-Controlled Key CWE-787 Out-of-bounds Write CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') CWE-798 Use of Hard-coded Credentials CWE-916 Use of Password Hash With Insufficient Computational Effort