MyBivona
Online tracheostomy tube configurator. Attributes come from ICU Medical's own public documentation for this product.
Attributes
Properties (MITRE EMB3D)
PID-31 Application-level software is present and running on the device PID-311 Device includes the usage of a web/HTTP applications PID-33 Device includes interactive applications, services, or user interfaces PID-332 Device includes authenticated services PID-3321 Device includes passwords to authenticate the users
Attributes: component types
Generic Application Local Application Local Service User Interface Web Application
Attributes: assets
Credentials Report Data User Data
Attributes: dataflows
Clinician to MyBivona configurator (account registration email and name)
Matched threat intel
Top 20 of 29
Advisories in our coverage that share attributes with this product, strongest first: a named product or component, the same device type or lineage, then the most shared attributes. A shared attribute is a lead, not a finding. The status column shows only what ICU Medical has said.
| # | Advisory | Date | Shared | ICU Medical status |
|---|---|---|---|---|
| 1 | BeaconMedaes TotalAlert Scroll Medical Air Systems expose stored passwords to unauthenticated users | May 24, 2018 | Same property (MITRE EMB3D)PID-33216 shared attributes: User accounts, Web interface, Device includes the usage of a web/HTTP applications (PID-311), Device includes passwords to authenticate the users (PID-3321) +2 | No response from manufacturer |
| 2 | Stored passwords recoverable in a Siemens imaging platform | Feb 10, 2026 | Same property (MITRE EMB3D)PID-33216 shared attributes: User accounts, Web interface, Device includes passwords to authenticate the users (PID-3321), Application-level software is present and running on the device (PID-31) +2 | No response from manufacturer |
| 3 | Philips Tasy EMR and WebPortal carry cross-site scripting and information exposure flaws | Apr 30, 2019 | Same property (MITRE EMB3D)PID-3116 shared attributes: Web interface, User accounts, Device includes the usage of a web/HTTP applications (PID-311), Web Application +2 | No response from manufacturer |
| 4 | Softneta MedDream PACS allows unauthenticated remote code execution | Sep 5, 2023 | Same property (MITRE EMB3D)PID-33215 shared attributes: User accounts, Web interface, Device includes passwords to authenticate the users (PID-3321), Generic Application +1 | No response from manufacturer |
| 5 | Path traversal in Thermo Fisher's Torrent Suite lets authenticated users read server files | Oct 15, 2026 | Same property (MITRE EMB3D)PID-3326 shared attributes: Device includes the usage of a web/HTTP applications (PID-311), Device includes authenticated services (PID-332), Application-level software is present and running on the device (PID-31), Web Application +2 | No response from manufacturer |
| 6 | Philips PageWriter TC cardiographs expose a hard-coded superuser password and unchecked input | Aug 16, 2018 | Same property (MITRE EMB3D)PID-33215 shared attributes: User accounts, Device includes passwords to authenticate the users (PID-3321), Generic Application, User Interface +1 | No response from manufacturer |
| 7 | Philips Clinical Collaboration Platform 12.2.1 and earlier has five web and authentication flaws | Sep 17, 2020 | Same property (MITRE EMB3D)PID-3114 shared attributes: Web interface, User accounts, Device includes the usage of a web/HTTP applications (PID-311), Web Application | No response from manufacturer |
| 8 | Hillrom Welch Allyn ELI resting electrocardiographs contain hard-coded passwords | Jun 16, 2022 | Same property (MITRE EMB3D)PID-33213 shared attributes: User accounts, Device includes passwords to authenticate the users (PID-3321), Credentials | No response from manufacturer |
| 9 | BD Pyxis products may still run on shared default operating system credentials | May 31, 2022 | Same property (MITRE EMB3D)PID-33213 shared attributes: User accounts, Device includes passwords to authenticate the users (PID-3321), Credentials | No response from manufacturer |
| 10 | Change Healthcare PeerVue Web Server leaks technical details in HTTP error messages | Oct 4, 2018 | Same property (MITRE EMB3D)PID-3113 shared attributes: Web interface, Device includes the usage of a web/HTTP applications (PID-311), Web Application | No response from manufacturer |
| 11 | B. Braun SpaceStation with SpaceCom module has an open redirect in its web server | Mar 23, 2017 | Same property (MITRE EMB3D)PID-3113 shared attributes: Web interface, Device includes the usage of a web/HTTP applications (PID-311), Web Application | No response from manufacturer |
| 12 | Hard-coded credentials and client-side auth in nuclear-medicine software | Dec 2, 2025 | 9 shared attributesUser accounts, Web interface, Cloud connectivity, Device includes authenticated services (PID-332) +5 | No response from manufacturer |
| 13 | B. Braun Battery Pack SP with Wi-Fi web server eval injection gives root on the pump module | Apr 13, 2023 | 6 shared attributesWeb interface, User accounts, Device includes the usage of a web/HTTP applications (PID-311), Device includes passwords to authenticate the users (PID-3321) +2 | No response from manufacturer |
| 14 | Philips DoseWise Portal hard-codes its database credentials and stores logins in clear text | Aug 17, 2017 | 6 shared attributesUser accounts, Web interface, Device includes the usage of a web/HTTP applications (PID-311), Device includes passwords to authenticate the users (PID-3321) +2 | No response from manufacturer |
| 15 | Login credentials exposed on the workstation in a GE imaging viewer | Mar 16, 2026 | 7 shared attributesUser accounts, Web interface, Application-level software is present and running on the device (PID-31), Device includes authenticated services (PID-332) +3 | No response from manufacturer |
| 16 | OpenClinic GA advisory lists authentication bypass, file upload and SQL abuse flaws | Jul 2, 2020 | 5 shared attributesUser accounts, Web interface, Device includes passwords to authenticate the users (PID-3321), Web Application +1 | No response from manufacturer |
| 17 | Swisslog Translogic Nexus Control Panel ships hard-coded root passwords and unvalidated updates | Aug 3, 2021 | 6 shared attributesTube, User accounts, Device includes passwords to authenticate the users (PID-3321), Local Service +2 | No response from manufacturer |
| 18 | Fresenius Kabi PharmaHelp allows privilege escalation through captured login data | Nov 24, 2023 | 5 shared attributesUser accounts, Device includes passwords to authenticate the users (PID-3321), Generic Application, Credentials +1 | No response from manufacturer |
| 19 | BD Alaris Infusion Central leaves a recoverable database password after installation | Feb 16, 2023 | 5 shared attributesUser accounts, Device includes passwords to authenticate the users (PID-3321), Local Application, Credentials +1 | No response from manufacturer |
| 20 | Hillrom Welch Allyn cardiology software let SSO users log in as any AD account without a password | Dec 9, 2021 | 5 shared attributesUser accounts, Device includes passwords to authenticate the users (PID-3321), Generic Application, User Interface +1 | No response from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-202 Exploitable System Network Stack Component TID-204 Untrusted Programs Can Access Privileged OS Functions TID-205 Existing OS Tools Maliciously Used for Device Manipulation TID-210 Device Vulnerabilities Unpatchable TID-211 Device Allows Unauthenticated Firmware Installation TID-219 OS/Kernel Privilege Escalation TID-221 Authentication Bypass By Message Replay TID-226 Device leaks security information in logs TID-301 Applications Binaries Modified TID-303 Excessive Trust in Offboard Management/IDE Software TID-310 Remotely Accessible Unauthenticated Services TID-311 Default Credentials TID-312 Credential Change Mechanism Can Be Abused TID-315 Password Retrieval Mechanism Abused TID-317 Predictable Cryptographic Key TID-318 Insecure Cryptographic Implementation TID-319 Cross Site Scripting (XSS) TID-320 SQL Injection TID-323 Path Traversal TID-324 HTTP Direct Object Reference TID-327 Out of Bounds Memory Access TID-328 Hardcoded Credentials TID-329 Improper Password Storage TID-408 Unencrypted Sensitive Data Communication
CWE weaknesses
CWE-1104 Use of Unmaintained Third Party Components CWE-1188 Insecure Default Initialization of Resource CWE-1392 Use of Default Credentials CWE-1395 Dependency on Vulnerable Third-Party Component CWE-200 Exposure of Sensitive Information to an Unauthorized Actor CWE-276 Incorrect Default Permissions CWE-284 Improper Access Control CWE-294 Authentication Bypass by Capture-replay CWE-321 Use of Hard-coded Cryptographic Key CWE-427 Uncontrolled Search Path Element CWE-522 Insufficiently Protected Credentials CWE-639 Authorization Bypass Through User-Controlled Key CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') CWE-798 Use of Hard-coded Credentials CWE-916 Use of Password Hash With Insufficient Computational Effort