CISA added CVE-2026-90817, a critical REDCap flaw requiring no authentication, to its Known Exploited Vulnerabilities catalog November 18 after an unidentified actor used it to deploy the XMRig cryptominer; the research data platform drew a year-long China-nexus intrusion Google reported in June. The extortion group Falcon claimed a 104.76 GB haul from Fisher & Paykel Healthcare November 23, including device documentation and a full Salesforce CRM export, a month after the company confirmed a narrower breach limited to two employee email accounts. The extortion group n0n named GRAIL and Guardant Health, two oncology diagnostics companies, in sequential leak-site listings November 19 and 20, claiming provider and order records; neither company has confirmed the claims. Prism Medical Products began notifying as many as 1.33 million people November 17 after discovering unauthorized access to its network on October 19; exposed data may include Social Security numbers and medical and insurance information. Amazon reported November 20 that autonomous AI agents it links with moderate confidence to a China nexus found and exploited a zero-day path traversal flaw in MONAI Label, an open source medical imaging tool, reaching a root shell in about 11 minutes; a fix is pending in an open pull request. FDA issued a discussion paper November 6 on cyber and AI risks in robotic medical devices with autonomous or remote teleoperation, warning errors could execute before a supervising clinician can intervene; comments are due January 5, 2027 ahead of a December 2 to 3 workshop. CISA added CVE-2026-90817, a critical REDCap flaw requiring no authentication, to its Known Exploited Vulnerabilities catalog November 18 after an unidentified actor used it to deploy the XMRig cryptominer; the research data platform drew a year-long China-nexus intrusion Google reported in June. The extortion group Falcon claimed a 104.76 GB haul from Fisher & Paykel Healthcare November 23, including device documentation and a full Salesforce CRM export, a month after the company confirmed a narrower breach limited to two employee email accounts. The extortion group n0n named GRAIL and Guardant Health, two oncology diagnostics companies, in sequential leak-site listings November 19 and 20, claiming provider and order records; neither company has confirmed the claims. Prism Medical Products began notifying as many as 1.33 million people November 17 after discovering unauthorized access to its network on October 19; exposed data may include Social Security numbers and medical and insurance information. Amazon reported November 20 that autonomous AI agents it links with moderate confidence to a China nexus found and exploited a zero-day path traversal flaw in MONAI Label, an open source medical imaging tool, reaching a root shell in about 11 minutes; a fix is pending in an open pull request. FDA issued a discussion paper November 6 on cyber and AI risks in robotic medical devices with autonomous or remote teleoperation, warning errors could execute before a supervising clinician can intervene; comments are due January 5, 2027 ahead of a December 2 to 3 workshop.
Wednesday, November 25, 2026 Issue #524  ·  Est. 2025
Independent brief for device makers

AMX Navigate

Mobile X-ray system. Attributes come from GE HealthCare's own public documentation for this product.

Attributes

Attributes: materials
InSite
Attributes: component types
API Actuator Display Firmware Generic Application Library Local Application Local Service Motor Sensor Modules Storage User Interface
Attributes: interface types
TCP Wireless
Attributes: assets
Patient Data Software Configuration Software Update Telemetry Data
Attributes: dataflows
AMX Navigate to remote monitoring via OnWatch and InSite Barcode reader to worklist for patient matching Detector to AMX Navigate over wireless link Remote service to AMX Navigate for software upload via eDelivery

Matched threat intel

19

Advisories in our coverage that share attributes with this product, strongest first: a named product or component, the same device type or lineage, then the most shared attributes. A shared attribute is a lead, not a finding. The status column shows only what GE HealthCare has said.

#AdvisoryDateSharedGE HealthCare status
1A DICOM viewer that did not check its update server certificateFeb 20, 2025Same property (MITRE EMB3D)PID-27514 shared attributes: Imaging family, Field-updatable firmware, Cloud connectivity, Handles patient data +10No response from manufacturer
2Philips IntelliBridge EC40 and EC80 hubs allow weak SSH ciphersNov 14, 2019Same property (MITRE EMB3D)PID-41138 shared attributes: Remote access, Handles patient data, Device exposes remote network services (PID-41), Device includes cryptographic functions for sensitive data, such as encryption or authentication (PID-4113) +4No response from manufacturer
3Medtronic 2090 CareLink and 29901 Encore programmers accept updates without verifying their originFeb 27, 2018Same property (MITRE EMB3D)PID-2756 shared attributes: Field-updatable firmware, Cloud connectivity, Device includes support for firmware/software updates (PID-27), Generic Application +2No response from manufacturer
4MicroDicom DICOM Viewer 2024.03 fails to validate its update server certificateFeb 6, 2025Same property (MITRE EMB3D)PID-2755 shared attributes: Imaging family, Field-updatable firmware, Device includes support for firmware/software updates (PID-27), Local Application +1No response from manufacturer
5Philips Veradius Unity, Pulsera and Endura Dual WAN routers use weak encryptionDec 19, 2019Same property (MITRE EMB3D)PID-41136 shared attributes: Wireless connectivity, Hospital network, Local Application, User Interface +2No response from manufacturer
6Baxter Phoenix hemodialysis system sends treatment and prescription data in cleartextJun 18, 2020Exposed to the same EMB3D threatTID-4115 shared attributes: Hospital network, Handles patient data, Generic Application, TCP +1No response from manufacturer
7BridgeLink 26.9.0 closes the Mirth Connect flaws CISA flagged, plus eight inherited CVEsOct 1, 202611 shared attributesApplication-level software is present and running on the device (PID-31), Device exposes remote network services (PID-41), Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations (PID-411), Device includes support for firmware/software updates (PID-27) +7No response from manufacturer
8Abbott ICDs and CRT-Ds allow RF authentication bypass and battery drainApr 17, 20189 shared attributesWireless connectivity, Field-updatable firmware, Remote access, Device includes support for firmware/software updates (PID-27) +5No response from manufacturer
9Six flaws in J4Care's dcm4chee-arc-light let attackers delete or tamper with stored medical imagesOct 15, 202611 shared attributesImaging family, Device exposes remote network services (PID-41), Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations (PID-411), Application-level software is present and running on the device (PID-31) +7No response from manufacturer
10Abbott Accent, Anthem, Assurity and Allure pacemakers get firmware fix for RF authentication bypassAug 29, 201710 shared attributesWireless connectivity, Field-updatable firmware, Handles patient data, Device includes support for firmware/software updates (PID-27) +6No response from manufacturer
11Philips lists MR, SPECT, ultrasound and telemetry products in Urgent/11 VxWorks advisoryAug 1, 20197 shared attributesImaging family, Mobile, Hospital network, Device exposes remote network services (PID-41) +3No response from manufacturer
12Medtronic MyCareLink monitors expose a debug port with a hard-coded OS passwordJun 28, 20186 shared attributesWireless connectivity, Field-updatable firmware, Device includes remotely-initiated firmware/software updates (PID-275), Generic Application +2No response from manufacturer
13Carestream DRX wireless detectors affected by KRACK WPA2 key reinstallation flawsNov 1, 20175 shared attributesImaging family, Wireless connectivity, Device includes cryptographic functions for sensitive data, such as encryption or authentication (PID-4113), Firmware +1No response from manufacturer
14Baxter warns of a Newmar radio PIM file flaw in Connex vital signs monitorsFeb 18, 20266 shared attributesWireless connectivity, Field-updatable firmware, Device includes support for firmware/software updates (PID-27), Wireless +2No response from manufacturer
15Philips lists Azurion, EPIQ and Affiniti under Windows IPv6 flaw CVE-2024-38063Aug 30, 20245 shared attributesImaging family, Mobile, Hospital network, TCP +1No response from manufacturer
16bioMérieux says three Access:7 flaws reach VILINK with Axeda, rated low risk behind the firewallMar 8, 20225 shared attributesRemote access, Device includes remotely-initiated firmware/software updates (PID-275), Local Service, TCP +1No response from manufacturer
17BD Alaris 8000 PC unit stores wireless network credentials unencrypted in flash memoryJan 17, 20175 shared attributesWireless connectivity, Hospital network, Storage, Wireless +1No response from manufacturer
18Canon Medical lists Vitrea Advanced 7.x and the Alphenix Angio Workstation as using affected Log4jMar 28, 20223 shared attributesImaging family, Library, TCPNo response from manufacturer
19Carestream patches Axeda clients behind Smart Link remote management for Access:7Mar 8, 20224 shared attributesRemote access, Local Service, TCP, Software UpdateNo response from manufacturer

Threats and weaknesses in matched advisories