LIVE FEED
CISA added CVE-2026-90817, a critical REDCap flaw requiring no authentication, to its Known Exploited Vulnerabilities catalog November 18 after an unidentified actor used it to deploy the XMRig cryptominer; the research data platform drew a year-long China-nexus intrusion Google reported in June. The extortion group Falcon claimed a 104.76 GB haul from Fisher & Paykel Healthcare November 23, including device documentation and a full Salesforce CRM export, a month after the company confirmed a narrower breach limited to two employee email accounts. The extortion group n0n named GRAIL and Guardant Health, two oncology diagnostics companies, in sequential leak-site listings November 19 and 20, claiming provider and order records; neither company has confirmed the claims. Prism Medical Products began notifying as many as 1.33 million people November 17 after discovering unauthorized access to its network on October 19; exposed data may include Social Security numbers and medical and insurance information. Amazon reported November 20 that autonomous AI agents it links with moderate confidence to a China nexus found and exploited a zero-day path traversal flaw in MONAI Label, an open source medical imaging tool, reaching a root shell in about 11 minutes; a fix is pending in an open pull request. FDA issued a discussion paper November 6 on cyber and AI risks in robotic medical devices with autonomous or remote teleoperation, warning errors could execute before a supervising clinician can intervene; comments are due January 5, 2027 ahead of a December 2 to 3 workshop. CISA added CVE-2026-90817, a critical REDCap flaw requiring no authentication, to its Known Exploited Vulnerabilities catalog November 18 after an unidentified actor used it to deploy the XMRig cryptominer; the research data platform drew a year-long China-nexus intrusion Google reported in June. The extortion group Falcon claimed a 104.76 GB haul from Fisher & Paykel Healthcare November 23, including device documentation and a full Salesforce CRM export, a month after the company confirmed a narrower breach limited to two employee email accounts. The extortion group n0n named GRAIL and Guardant Health, two oncology diagnostics companies, in sequential leak-site listings November 19 and 20, claiming provider and order records; neither company has confirmed the claims. Prism Medical Products began notifying as many as 1.33 million people November 17 after discovering unauthorized access to its network on October 19; exposed data may include Social Security numbers and medical and insurance information. Amazon reported November 20 that autonomous AI agents it links with moderate confidence to a China nexus found and exploited a zero-day path traversal flaw in MONAI Label, an open source medical imaging tool, reaching a root shell in about 11 minutes; a fix is pending in an open pull request. FDA issued a discussion paper November 6 on cyber and AI risks in robotic medical devices with autonomous or remote teleoperation, warning errors could execute before a supervising clinician can intervene; comments are due January 5, 2027 ahead of a December 2 to 3 workshop.
Wednesday, November 25, 2026 Issue #524  ·  Est. 2025
Independent brief for device makers

DryPix Smart Dry Laser Imager

Dry laser medical film imager. Attributes come from Fujifilm Healthcare's own public documentation for this product.

Attributes

Platform
Windows Windows XP
Attributes: materials
Windows XP
Attributes: component types
Local Service Operating System
Attributes: interface types
TCP

Matched threat intel

Top 20 of 22

Advisories in our coverage that share attributes with this product, strongest first: a named product or component, the same device type or lineage, then the most shared attributes. A shared attribute is a lead, not a finding. The status column shows only what Fujifilm Healthcare has said.

#AdvisoryDateSharedFujifilm Healthcare status
1Thermo Fisher Xcalibur and Foundation driver packages allow local privilege escalationJan 22, 2025Same platformWindows1 shared attribute: Named operating systemNo response from manufacturer
2Carestream DirectView and ImageView systems affected by BlueKeep and DejaBlue RDP flawsMay 16, 20197 shared attributesImaging family, Named operating system, Device includes OS/kernel (PID-23), Device exposes remote network services (PID-41) +3No response from manufacturer
3Canon Medical lists Windows 7 and 10 imaging systems as possibly affected by PrintNightmareAug 24, 20216 shared attributesImaging family, Named operating system, Device includes OS/kernel (PID-23), Operating System +2No response from manufacturer
4Canon Medical lists Alphenix, CT TSX and MRT systems as affected by DejaBlue RDP flawsAug 20, 20196 shared attributesImaging family, Named operating system, Device includes OS/kernel (PID-23), Operating System +2No response from manufacturer
5Hologic validates MS17-010 WannaCry patch for Selenia, Dimensions and SecurViewJul 25, 20175 shared attributesImaging family, Named operating system, Device includes OS/kernel (PID-23), Operating System +1No response from manufacturer
6Philips names PACS and imaging servers in Zerologon CVE-2020-1472 advisorySep 14, 20205 shared attributesImaging family, Named operating system, Device includes OS/kernel (PID-23), Local Service +1No response from manufacturer
7Hologic urges MS17-010 patch on Skeletal Health DXA and Fluoroscan systemsJul 25, 20175 shared attributesImaging family, Named operating system, Device exposes remote network services (PID-41), Operating System +1No response from manufacturer
8Philips lists IntelliBridge Enterprise and IntelliVue software under Windows NFS flaw CVE-2022-24491Apr 15, 20225 shared attributesImaging family, Named operating system, Operating System, Local Service +1No response from manufacturer
9Philips lists 54 products under PrintNightmare, the Windows Print Spooler RCE CVE-2021-34527Jul 2, 20215 shared attributesImaging family, Named operating system, Operating System, Local Service +1No response from manufacturer
10Philips FocalPoint before v2.2 exposed to Linux Copy Fail root escalationMay 4, 20264 shared attributesImaging family, Named operating system, Device includes OS/kernel (PID-23), Operating SystemNo response from manufacturer
11Philips lists IntelliSite Pathology Ultra Fast Scanner under PwnKit CVE-2021-4034Jan 28, 20224 shared attributesImaging family, Named operating system, Device includes OS/kernel (PID-23), Operating SystemNo response from manufacturer
12BD lists more than 20 product lines in scope for PrintNightmare CVE-2021-34527Aug 16, 20214 shared attributesImaging family, Named operating system, Local Service, Operating SystemNo response from manufacturer
13Philips lists PIC iX, ICCA and IntelliVue Guardian under the Print Spooler flaw CVE-2021-34481Aug 13, 20214 shared attributesImaging family, Named operating system, Operating System, Local ServiceNo response from manufacturer
14Canon Medical lists ultrasound and MR imaging products as affected by MSMQ flaw CVE-2023-21554Jun 9, 20254 shared attributesImaging family, Named operating system, Device exposes remote network services (PID-41), TCPNo response from manufacturer
15Philips lists Corsium and IntelliSpace PACS in Windows downgrade attack noticeSep 20, 20243 shared attributesImaging family, Named operating system, Operating SystemNo response from manufacturer
16Philips lists HeartStart, IntelliVue and IntelliSpace products as Windows Server 2012 reaches end of lifeOct 10, 20233 shared attributesImaging family, Named operating system, Operating SystemNo response from manufacturer
17Philips lists IntelliSpace Portal and Capsule Neuron under Windows DCOM bypass CVE-2021-26414Aug 17, 20223 shared attributesImaging family, Named operating system, Operating SystemNo response from manufacturer
18Philips lists IntelliVue Guardian, IntelliBridge and PICiX under Windows IKE flaw CVE-2022-21849Mar 23, 20223 shared attributesImaging family, Named operating system, Operating SystemNo response from manufacturer
19Philips reviews 52 products running Windows 7 and Server 2008 R2 at end of supportJan 14, 20203 shared attributesImaging family, Named operating system, Operating SystemNo response from manufacturer
20J&J Surgical Vision systems run QNX versions with BadAlloc flaw CVE-2021-22156Sep 24, 20213 shared attributesLaser, Named operating system, Device includes OS/kernel (PID-23)No response from manufacturer

Threats and weaknesses in matched advisories