HMS6500 Multi-parameter Vital Signs Monitor
Multi-parameter vital signs monitor. Attributes come from Contec's own public documentation for this product.
Attributes
Signals
Properties (MITRE EMB3D)
PID-33 Device includes interactive applications, services, or user interfaces PID-332 Device includes authenticated services PID-3321 Device includes passwords to authenticate the users PID-411 Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations
Attributes: component types
API Battery Cloud Service Display Local Application Local Service Sensor Modules User Interface
Attributes: interface types
Cellular WiFi
Attributes: assets
Credentials Patient Data User Data
Attributes: dataflows
Monitor to Experts via network (ECG, SpO2, PR, NIBP, TEMP, Blood Glucose for consultation) Monitor to PHMS Data Center (measured data and ECG)
Matched threat intel
Top 20 of 39
Advisories in our coverage that share attributes with this product, strongest first: a named product or component, the same device type or lineage, then the most shared attributes. A shared attribute is a lead, not a finding. The status column shows only what Contec has said.
| # | Advisory | Date | Shared | Contec status |
|---|---|---|---|---|
| 1 | Mira’s cloud login accepted any password and returned a session token | Aug 11, 2026 | 14 shared attributesPatient monitoring family, Monitor, Handles patient data, Cloud connectivity +10 | No response from manufacturer |
| 2 | A bundled message broker shipped with guest:guest still enabled | May 29, 2026 | 12 shared attributesWired network, User accounts, Remote access, Patient or study database +8 | No response from manufacturer |
| 3 | Contec CMS8000 patient monitors crash on a UDP broadcast and accept unauthenticated USB firmware | Sep 1, 2022 | 10 shared attributesPatient monitoring family, Vital, Sign, Wireless connectivity +6 | No response from manufacturer |
| 4 | Default credentials across a line of diagnostic instruments | Dec 17, 2024 | 10 shared attributesHandles patient data, Wired network, Remote access, User accounts +6 | No response from manufacturer |
| 5 | A hard-coded VNC password on a bioreactor, base score 9.8 | May 26, 2026 | 10 shared attributesRemote access, User accounts, Wireless connectivity, Wired network +6 | No response from manufacturer |
| 6 | Philips SureSigns VS4 monitors can be pushed into sending patient data to a remote destination | Aug 20, 2020 | 8 shared attributesPatient monitoring family, Vital, Sign, User accounts +4 | No response from manufacturer |
| 7 | Philips IntelliVue WLAN modules accept malicious firmware through a hard-coded FTP password | Sep 12, 2019 | 7 shared attributesPatient monitoring family, Monitor, Wireless connectivity, Physiological waveform processing +3 | No response from manufacturer |
| 8 | Empty passwords and cleartext storage in a home cardiac monitor | Jul 24, 2025 | 9 shared attributesMonitor, Handles patient data, User accounts, Wireless connectivity +5 | No response from manufacturer |
| 9 | Qardio Heart Health apps expose credentials that reach an engineering backdoor | Feb 13, 2025 | 7 shared attributesPatient monitoring family, Monitor, Wireless connectivity, User accounts +3 | No response from manufacturer |
| 10 | Orthanc DICOM Server Patches Integer Overflow That Corrupts Heap Memory | Sep 10, 2026 | 8 shared attributesRemote access, User accounts, Wired network, Patient or study database +4 | No response from manufacturer |
| 11 | Two maximum-severity flaws in a ventilation system | Nov 14, 2024 | 7 shared attributesUser accounts, Wireless connectivity, Wired network, Handles patient data +3 | No response from manufacturer |
| 12 | B. Braun Battery Pack SP with Wi-Fi web server eval injection gives root on the pump module | Apr 13, 2023 | 6 shared attributesWireless connectivity, User accounts, Device includes passwords to authenticate the users (PID-3321), Battery +2 | No response from manufacturer |
| 13 | Login credentials exposed on the workstation in a GE imaging viewer | Mar 16, 2026 | 7 shared attributesUser accounts, Remote access, Handles patient data, Device includes authenticated services (PID-332) +3 | No response from manufacturer |
| 14 | BD Alaris Infusion Central leaves a recoverable database password after installation | Feb 16, 2023 | 6 shared attributesPatient or study database, User accounts, Device includes passwords to authenticate the users (PID-3321), Local Application +2 | No response from manufacturer |
| 15 | Fresenius Kabi PharmaHelp allows privilege escalation through captured login data | Nov 24, 2023 | 5 shared attributesUser accounts, Patient or study database, Device includes passwords to authenticate the users (PID-3321), Credentials +1 | No response from manufacturer |
| 16 | Veradigm says stolen vendor credentials reached a company API and patient Social Security numbers | Sep 8, 2026 | 6 shared attributesDevice exposes remote services with the ability to send, receive, view or modify sensitive information or configurations (PID-411), Device includes authenticated services (PID-332), Device includes passwords to authenticate the users (PID-3321), API +2 | No response from manufacturer |
| 17 | BD Pyxis products may still run on shared default operating system credentials | May 31, 2022 | 6 shared attributesUser accounts, Handles patient data, Wired network, Device includes passwords to authenticate the users (PID-3321) +2 | No response from manufacturer |
| 18 | Philips DoseWise Portal hard-codes its database credentials and stores logins in clear text | Aug 17, 2017 | 6 shared attributesPatient or study database, User accounts, Handles patient data, Device includes passwords to authenticate the users (PID-3321) +2 | No response from manufacturer |
| 19 | Philips Alice 6 sleep system has hard-coded credentials and cleartext patient data | Mar 26, 2018 | 6 shared attributesHandles patient data, Physiological waveform processing, User accounts, Device includes passwords to authenticate the users (PID-3321) +2 | No response from manufacturer |
| 20 | ShinyHunters claims 284 million records after vishing McKesson employees | Aug 31, 2026 | 6 shared attributesDevice includes authenticated services (PID-332), Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations (PID-411), Cloud Service, Credentials +2 | No response from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-111 Untrusted External Storage TID-115 Firmware/Data Extraction via Hardware Interface TID-116 Latent Privileged Access Port TID-119 Latent Hardware Debug Port Allows Memory/Code Manipulation TID-202 Exploitable System Network Stack Component TID-204 Untrusted Programs Can Access Privileged OS Functions TID-205 Existing OS Tools Maliciously Used for Device Manipulation TID-210 Device Vulnerabilities Unpatchable TID-211 Device Allows Unauthenticated Firmware Installation TID-213 Faulty FW/SW Update Integrity Verification TID-219 OS/Kernel Privilege Escalation TID-221 Authentication Bypass By Message Replay TID-222 Critical System Service May Be Disabled TID-224 Excessive Access via Software Diagnostic Features TID-226 Device leaks security information in logs TID-303 Excessive Trust in Offboard Management/IDE Software TID-310 Remotely Accessible Unauthenticated Services TID-311 Default Credentials TID-312 Credential Change Mechanism Can Be Abused TID-313 Unauthenticated Session Changes Credential TID-314 Passwords Can Be Guessed Using Brute-Force Attempts TID-315 Password Retrieval Mechanism Abused TID-316 Incorrect Certificate Verification Allows Authentication Bypass TID-317 Predictable Cryptographic Key TID-318 Insecure Cryptographic Implementation TID-320 SQL Injection TID-324 HTTP Direct Object Reference TID-326 Insecure Deserialization TID-327 Out of Bounds Memory Access TID-328 Hardcoded Credentials TID-329 Improper Password Storage TID-401 Undocumented Protocol Features TID-404 Remotely Triggerable Deadlock/DoS TID-405 Network Stack Resource Exhaustion TID-406 Unauthorized Messages or Connections TID-408 Unencrypted Sensitive Data Communication TID-411 Weak/Insecure Cryptographic Protocol
CWE weaknesses
CWE-1104 Use of Unmaintained Third Party Components CWE-1191 On-Chip Debug and Test Interface With Improper Access Control CWE-122 Heap-based Buffer Overflow CWE-125 Out-of-bounds Read CWE-1313 Hardware Allows Activation of Test or Debug Logic at Runtime CWE-1329 Reliance on Component That is Not Updateable CWE-1390 Weak Authentication CWE-1392 Use of Default Credentials CWE-1395 Dependency on Vulnerable Third-Party Component CWE-20 Improper Input Validation CWE-200 Exposure of Sensitive Information to an Unauthorized Actor CWE-284 Improper Access Control CWE-287 Improper Authentication CWE-294 Authentication Bypass by Capture-replay CWE-306 Missing Authentication for Critical Function CWE-319 Cleartext Transmission of Sensitive Information CWE-321 Use of Hard-coded Cryptographic Key CWE-326 Inadequate Encryption Strength CWE-400 Uncontrolled Resource Consumption CWE-427 Uncontrolled Search Path Element CWE-476 NULL Pointer Dereference CWE-502 Deserialization of Untrusted Data CWE-506 Embedded Malicious Code CWE-522 Insufficiently Protected Credentials CWE-639 Authorization Bypass Through User-Controlled Key CWE-787 Out-of-bounds Write CWE-798 Use of Hard-coded Credentials CWE-912 Hidden Functionality CWE-916 Use of Password Hash With Insufficient Computational Effort