CMS6800 Patient Monitor
Patient monitor. Attributes come from Contec's own public documentation for this product.
Attributes
Properties (MITRE EMB3D)
Attributes: component types
Battery Display Generic Hardware Local Service Sensor Modules
Attributes: interface types
Unknown Wireless
Attributes: assets
Sensor Data
Attributes: dataflows
Patient Monitor to Central Monitoring System over wired or wireless network
Matched threat intel
9
Advisories in our coverage that share attributes with this product, strongest first: a named product or component, the same device type or lineage, then the most shared attributes. A shared attribute is a lead, not a finding. The status column shows only what Contec has said.
| # | Advisory | Date | Shared | Contec status |
|---|---|---|---|---|
| 1 | A null-pointer dereference can take down a central patient monitor | Oct 23, 2025 | Same signals9 shared attributes: Patient monitoring family, Patient, Monitor, Hospital network +5 | No response from manufacturer |
| 2 | Philips PIC iX and Efficia CM Series carry a hard-coded key and weak crypto | Nov 18, 2021 | 7 shared attributesPatient monitoring family, Patient, Monitor, Physiological waveform processing +3 | No response from manufacturer |
| 3 | Philips IntelliVue Information Center iX B.02 can be knocked offline by repeated UDP requests | Aug 21, 2018 | 6 shared attributesPatient monitoring family, Patient, Monitor, Wired network +2 | No response from manufacturer |
| 4 | Philips IntelliVue MX40 WLAN monitors can drop local alarming after 802.11 faults | Sep 12, 2017 | 6 shared attributesPatient monitoring family, Patient, Monitor, Wireless connectivity +2 | No response from manufacturer |
| 5 | Philips discloses availability flaw in e-Alert hardware 2.7 and prior | Mar 29, 2022 | 6 shared attributesPatient monitoring family, Monitor, Wired network, Device exposes remote network services (PID-41) +2 | No response from manufacturer |
| 6 | Philips PIC iX 4.x listed as affected by two Windows DHCP vulnerabilities | Jun 22, 2026 | 5 shared attributesPatient monitoring family, Patient, Monitor, Wired network +1 | No response from manufacturer |
| 7 | Philips IntelliVue and Avalon monitors let an unauthenticated attacker read and write memory | Jun 5, 2018 | 6 shared attributesPatient monitoring family, Patient, Monitor, Hospital network +2 | No response from manufacturer |
| 8 | Baxter Welch Allyn Connex Spot Monitor used a default cryptographic key | May 30, 2024 | 5 shared attributesPatient monitoring family, Patient, Monitor, Hospital network +1 | No response from manufacturer |
| 9 | Philips lists IntelliVue XDS and PICiX under WinVerifyTrust signature flaw CVE-2013-3900 | May 3, 2023 | 3 shared attributesPatient monitoring family, Patient, Monitor | No response from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-202 Exploitable System Network Stack Component TID-210 Device Vulnerabilities Unpatchable TID-221 Authentication Bypass By Message Replay TID-222 Critical System Service May Be Disabled TID-301 Applications Binaries Modified TID-310 Remotely Accessible Unauthenticated Services TID-311 Default Credentials TID-317 Predictable Cryptographic Key TID-327 Out of Bounds Memory Access TID-329 Improper Password Storage TID-404 Remotely Triggerable Deadlock/DoS TID-405 Network Stack Resource Exhaustion TID-411 Weak/Insecure Cryptographic Protocol
CWE weaknesses
CWE-1104 Use of Unmaintained Third Party Components CWE-1188 Insecure Default Initialization of Resource CWE-1329 Reliance on Component That is Not Updateable CWE-20 Improper Input Validation CWE-276 Incorrect Default Permissions CWE-294 Authentication Bypass by Capture-replay CWE-321 Use of Hard-coded Cryptographic Key CWE-400 Uncontrolled Resource Consumption CWE-476 NULL Pointer Dereference CWE-916 Use of Password Hash With Insufficient Computational Effort