Latitude NXT
Remote patient management system. Attributes come from Boston Scientific's own public documentation for this product.
Attributes
Signals
Properties (MITRE EMB3D)
PID-31 Application-level software is present and running on the device PID-311 Device includes the usage of a web/HTTP applications PID-33 Device includes interactive applications, services, or user interfaces PID-41 Device exposes remote network services PID-411 Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations PID-4113 Device includes cryptographic functions for sensitive data, such as encryption or authentication
Attributes: component types
API Generic Application Generic Hardware Library Local Application Local Service Mobile Application User Interface Web Application
Attributes: interface types
Cellular TCP Wireless
Attributes: assets
Patient Data Report Data Software Configuration Telemetry Data
Attributes: dataflows
Communicator to EMR via HL7 Communicator to secure data management system (cardiac health and device information) Implanted device to Communicator via wireless interrogation LATITUDE Consult System to LATITUDE NXT website LATITUDE NXT website to EMR
Matched threat intel
Top 20 of 36
Advisories in our coverage that share attributes with this product, strongest first: a named product or component, the same device type or lineage, then the most shared attributes. A shared attribute is a lead, not a finding. The status column shows only what Boston Scientific has said.
| # | Advisory | Date | Shared | Boston Scientific status |
|---|---|---|---|---|
| 1 | Dario Health glucose monitoring app and servers exposed cross-user health data | Feb 27, 2025 | Same property (MITRE EMB3D)PID-31110 shared attributes: Cloud connectivity, Mobile app, Handles patient data, Web interface +6 | No response from manufacturer |
| 2 | Missing authentication lets an attacker rewrite a cardiac wearable | May 28, 2026 | Same property (MITRE EMB3D)PID-41112 shared attributes: Wireless connectivity, Handles patient data, Mobile app, Remote access +8 | No response from manufacturer |
| 3 | LifePoint Informatics Patient Portal generated lab report PDFs from a URL and a patient ID | Apr 5, 2022 | Same property (MITRE EMB3D)PID-3118 shared attributes: Patient, Web interface, Handles patient data, Cloud connectivity +4 | No response from manufacturer |
| 4 | B. Braun SpaceStation with SpaceCom module has an open redirect in its web server | Mar 23, 2017 | Same property (MITRE EMB3D)PID-3116 shared attributes: Web interface, Hospital network, Device includes the usage of a web/HTTP applications (PID-311), Web Application +2 | No response from manufacturer |
| 5 | Philips IntelliBridge EC40 and EC80 hubs allow weak SSH ciphers | Nov 14, 2019 | Same property (MITRE EMB3D)PID-41138 shared attributes: Remote access, Handles patient data, Device exposes remote network services (PID-41), Device includes cryptographic functions for sensitive data, such as encryption or authentication (PID-4113) +4 | No response from manufacturer |
| 6 | Philips EncoreAnywhere exposes sensitive data in its HTTP headers | May 17, 2018 | Same property (MITRE EMB3D)PID-3115 shared attributes: Cloud connectivity, Web interface, Device includes the usage of a web/HTTP applications (PID-311), Web Application +1 | No response from manufacturer |
| 7 | Apollo Pharmacy APG-01 BT glucose meter sends readings over BLE in cleartext | Jun 18, 2026 | Same property (MITRE EMB3D)PID-4116 shared attributes: Wireless connectivity, Handles patient data, Home use, Mobile app +2 | No response from manufacturer |
| 8 | Change Healthcare PeerVue Web Server leaks technical details in HTTP error messages | Oct 4, 2018 | Same property (MITRE EMB3D)PID-3114 shared attributes: Web interface, Device includes the usage of a web/HTTP applications (PID-311), Web Application, TCP | No response from manufacturer |
| 9 | BPL PWS-01-BT weighing scale sends unencrypted, unauthenticated BLE data to the Be Well app | Sep 10, 2024 | Same signals5 shared attributes: Wireless connectivity, Mobile app, Home use, Mobile Application +1 | No response from manufacturer |
| 10 | Philips Veradius Unity, Pulsera and Endura Dual WAN routers use weak encryption | Dec 19, 2019 | Same property (MITRE EMB3D)PID-41137 shared attributes: Wireless connectivity, Hospital network, Generic Hardware, Local Application +3 | No response from manufacturer |
| 11 | Baxter Phoenix hemodialysis system sends treatment and prescription data in cleartext | Jun 18, 2020 | Exposed to the same EMB3D threatTID-4115 shared attributes: Hospital network, Handles patient data, Generic Application, TCP +1 | No response from manufacturer |
| 12 | Five flaws in Sante PACS Server, and one sends credentials in cleartext | Aug 12, 2025 | 15 shared attributesHL7 or FHIR integration, Web interface, Remote access, Handles patient data +11 | No response from manufacturer |
| 13 | A 10.0 SQL injection on a patient health portal | Sep 5, 2024 | 12 shared attributesPatient, Handles patient data, Cloud connectivity, Web interface +8 | No response from manufacturer |
| 14 | EMS patient-care app reflects unsanitized input into a WebView | Feb 10, 2026 | 12 shared attributesPatient, Handles patient data, Mobile app, Cloud connectivity +8 | No response from manufacturer |
| 15 | Unrestricted file upload on a PACS points straight at code execution | Apr 10, 2025 | 12 shared attributesFile import, Web interface, Remote access, Handles patient data +8 | No response from manufacturer |
| 16 | Fresenius Kabi Agilia Connect infusion accessories expose unauthenticated endpoints and weak TLS | Dec 21, 2021 | 11 shared attributesWeb interface, Wireless connectivity, Hospital network, Device includes the usage of a web/HTTP applications (PID-311) +7 | No response from manufacturer |
| 17 | Philips IntelliVue monitors and PIC iX skip certificate revocation and crash on bad input | Sep 10, 2020 | 11 shared attributesPatient, Hospital network, Handles patient data, Web interface +7 | No response from manufacturer |
| 18 | User enumeration on the CareLink Network, found at a conference | Dec 4, 2025 | 10 shared attributesRemote, Patient, Cloud connectivity, Web interface +6 | No response from manufacturer |
| 19 | GE CARESCAPE, ApexPro and CIC monitoring systems carry hard-coded SMB credentials and five more critical flaws | Jan 23, 2020 | 11 shared attributesPatient, Remote access, Web interface, Handles patient data +7 | No response from manufacturer |
| 20 | Philips reports no product impact from Next.js flaw CVE-2026-75604 | Sep 4, 2026 | 9 shared attributesCloud connectivity, Remote access, Web interface, Handles patient data +5 | No response from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-202 Exploitable System Network Stack Component TID-210 Device Vulnerabilities Unpatchable TID-213 Faulty FW/SW Update Integrity Verification TID-221 Authentication Bypass By Message Replay TID-222 Critical System Service May Be Disabled TID-226 Device leaks security information in logs TID-305 Program Executes Dangerous System Calls TID-310 Remotely Accessible Unauthenticated Services TID-311 Default Credentials TID-316 Incorrect Certificate Verification Allows Authentication Bypass TID-317 Predictable Cryptographic Key TID-318 Insecure Cryptographic Implementation TID-319 Cross Site Scripting (XSS) TID-320 SQL Injection TID-323 Path Traversal TID-324 HTTP Direct Object Reference TID-326 Insecure Deserialization TID-327 Out of Bounds Memory Access TID-328 Hardcoded Credentials TID-329 Improper Password Storage TID-401 Undocumented Protocol Features TID-404 Remotely Triggerable Deadlock/DoS TID-405 Network Stack Resource Exhaustion TID-406 Unauthorized Messages or Connections TID-407 Missing Message Replay Protection TID-408 Unencrypted Sensitive Data Communication TID-411 Weak/Insecure Cryptographic Protocol
CWE weaknesses
CWE-1104 Use of Unmaintained Third Party Components CWE-1188 Insecure Default Initialization of Resource CWE-1392 Use of Default Credentials CWE-1395 Dependency on Vulnerable Third-Party Component CWE-20 Improper Input Validation CWE-200 Exposure of Sensitive Information to an Unauthorized Actor CWE-22 Improper Limitation of a Pathname to a Restricted Directory CWE-276 Incorrect Default Permissions CWE-284 Improper Access Control CWE-290 Authentication Bypass by Spoofing CWE-294 Authentication Bypass by Capture-replay CWE-306 Missing Authentication for Critical Function CWE-319 Cleartext Transmission of Sensitive Information CWE-321 Use of Hard-coded Cryptographic Key CWE-326 Inadequate Encryption Strength CWE-400 Uncontrolled Resource Consumption CWE-434 Unrestricted Upload of File with Dangerous Type CWE-476 NULL Pointer Dereference CWE-522 Insufficiently Protected Credentials CWE-639 Authorization Bypass Through User-Controlled Key CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') CWE-798 Use of Hard-coded Credentials CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') CWE-916 Use of Password Hash With Insufficient Computational Effort