LabPro Connect Software
Microbiology information management software. Attributes come from Beckman Coulter's own public documentation for this product.
Attributes
Signals
Properties (MITRE EMB3D)
PID-12 Device includes Memory/Storage (external to CPU) PID-123 Device includes ROM, VRAM, or removable Storage PID-124 Device includes Random Access Memory (RAM) chips PID-23 Device includes OS/kernel PID-31 Application-level software is present and running on the device PID-33 Device includes interactive applications, services, or user interfaces PID-332 Device includes authenticated services PID-41 Device exposes remote network services PID-411 Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations
Platform
Windows Windows 10 Windows 2000 Windows 7 Windows Vista Windows XP
Attributes: materials
Windows 10 Windows Vista 32 Windows XP
Attributes: component types
API Generic Application Generic Hardware Local Application Local Service Memory Operating System Storage User Interface
Attributes: interface types
Ethernet TCP
Attributes: assets
Report Data
Attributes: dataflows
LabPro Connect computers to centralized LabPro database computer LabPro Connect to LIS (ID/AST results via single connection) LabPro Information Manager to Microsoft Excel (Antibiogram Export Tool) Multiple testing systems to LabPro Connect (consolidated data) Workstation computers to LabPro Information Manager over hospital LAN
Matched threat intel
Top 20 of 109
Advisories in our coverage that share attributes with this product, strongest first: a named product or component, the same device type or lineage, then the most shared attributes. A shared attribute is a lead, not a finding. The status column shows only what Beckman Coulter has said.
| # | Advisory | Date | Shared | Beckman Coulter status |
|---|---|---|---|---|
| 1 | Hologic urges MS17-010 patch on Skeletal Health DXA and Fluoroscan systems | Jul 25, 2017 | Same named componentWindows XP (= SP3)4 shared attributes: Named operating system, Device exposes remote network services (PID-41), Operating System, TCP | No response from manufacturer |
| 2 | BD Pyxis products may still run on shared default operating system credentials | May 31, 2022 | Same property (MITRE EMB3D)PID-238 shared attributes: User accounts, Hospital network, Wired network, Device includes OS/kernel (PID-23) +4 | No response from manufacturer |
| 3 | Login credentials exposed on the workstation in a GE imaging viewer | Mar 16, 2026 | Exposed to the same EMB3D threatTID-3296 shared attributes: User accounts, Hospital network, Role-based access, Application-level software is present and running on the device (PID-31) +2 | No response from manufacturer |
| 4 | Philips PageWriter TC cardiographs expose a hard-coded superuser password and unchecked input | Aug 16, 2018 | Exposed to the same EMB3D threatTID-3296 shared attributes: User accounts, Hospital network, Device includes OS/kernel (PID-23), Operating System +2 | No response from manufacturer |
| 5 | Philips iSite and IntelliSpace PACS carry default credentials in third-party software | Nov 8, 2018 | Exposed to the same EMB3D threatTID-3295 shared attributes: Off-the-shelf software, User accounts, Hospital network, Generic Application +1 | No response from manufacturer |
| 6 | Philips IntelliSpace Cardiovascular and Xcelera store credentials in cleartext | Nov 14, 2017 | Exposed to the same EMB3D threatTID-3295 shared attributes: Information, User accounts, Hospital network, Local Service +1 | No response from manufacturer |
| 7 | Stored passwords recoverable in a Siemens imaging platform | Feb 10, 2026 | Same signals5 shared attributes: User accounts, Role-based access, Hospital network, Application-level software is present and running on the device (PID-31) +1 | No response from manufacturer |
| 8 | Baxter PrismaFlex and PrisMax send treatment data to EMR systems without encryption or authentication | Jun 18, 2020 | Same property (MITRE EMB3D)PID-4115 shared attributes: Hospital network, User accounts, Generic Application, Generic Hardware +1 | No response from manufacturer |
| 9 | BD Alaris Infusion Central leaves a recoverable database password after installation | Feb 16, 2023 | Exposed to the same EMB3D threatTID-3295 shared attributes: Patient or study database, User accounts, Hospital network, Local Application +1 | No response from manufacturer |
| 10 | Philips DoseWise Portal hard-codes its database credentials and stores logins in clear text | Aug 17, 2017 | Same property (MITRE EMB3D)PID-3323 shared attributes: Patient or study database, User accounts, TCP | No response from manufacturer |
| 11 | Philips IntelliBridge Enterprise writes plaintext EMR credentials into its transaction logs | Jun 11, 2020 | Exposed to the same EMB3D threatTID-3293 shared attributes: User accounts, Hospital network, TCP | No response from manufacturer |
| 12 | Hillrom Welch Allyn ELI resting electrocardiographs contain hard-coded passwords | Jun 16, 2022 | Same signals2 shared attributes: User accounts, Hospital network | No response from manufacturer |
| 13 | Thermo Fisher Xcalibur and Foundation driver packages allow local privilege escalation | Jan 22, 2025 | Same platformWindows2 shared attributes: Named operating system, Local Application | No response from manufacturer |
| 14 | i-SENS SmartLog diabetes management software loads planted DLLs from its search path | Sep 7, 2017 | Same signals2 shared attributes: Named operating system, Local Application | No response from manufacturer |
| 15 | Philips issues WannaCry guidance naming IntelliSpace Portal Workstation IX and Event Management | May 15, 2017 | Same signals1 shared attribute: Hospital network | No response from manufacturer |
| 16 | Default credentials across a line of diagnostic instruments | Dec 17, 2024 | 10 shared attributesLab and diagnostics family, Microbiology, Wired network, User accounts +6 | No response from manufacturer |
| 17 | A legacy cardiology system, end-of-service since 2014, recalled for security | Jun 10, 2025 | 11 shared attributesInformation, Patient or study database, User accounts, Hospital network +7 | No response from manufacturer |
| 18 | Missing authentication on a DNA sequencer control plane | Oct 21, 2025 | 12 shared attributesLab and diagnostics family, User accounts, Patient or study database, Hospital network +8 | No response from manufacturer |
| 19 | Medtronic Valleylab FT10 and FX8 energy platforms ship hard-coded credentials and a vulnerable rssh | Nov 7, 2019 | 9 shared attributesUser accounts, Wired network, Off-the-shelf software, Device includes OS/kernel (PID-23) +5 | No response from manufacturer |
| 20 | Siemens PET/CT and SPECT systems on Windows 7 exposed to remote code execution through third-party services | Aug 3, 2017 | 9 shared attributesOff-the-shelf software, Named operating system, Wired network, Hospital network +5 | No response from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-103 Microarchitectural Side Channels TID-107 Unauthorized Direct Memory Access (DMA) TID-202 Exploitable System Network Stack Component TID-204 Untrusted Programs Can Access Privileged OS Functions TID-205 Existing OS Tools Maliciously Used for Device Manipulation TID-210 Device Vulnerabilities Unpatchable TID-217 Remotely Initiated Updates Can Cause DoS TID-219 OS/Kernel Privilege Escalation TID-221 Authentication Bypass By Message Replay TID-222 Critical System Service May Be Disabled TID-224 Excessive Access via Software Diagnostic Features TID-225 Logs can be manipulated on the device TID-226 Device leaks security information in logs TID-301 Applications Binaries Modified TID-310 Remotely Accessible Unauthenticated Services TID-311 Default Credentials TID-313 Unauthenticated Session Changes Credential TID-314 Passwords Can Be Guessed Using Brute-Force Attempts TID-316 Incorrect Certificate Verification Allows Authentication Bypass TID-317 Predictable Cryptographic Key TID-318 Insecure Cryptographic Implementation TID-320 SQL Injection TID-324 HTTP Direct Object Reference TID-326 Insecure Deserialization TID-327 Out of Bounds Memory Access TID-328 Hardcoded Credentials TID-329 Improper Password Storage TID-404 Remotely Triggerable Deadlock/DoS TID-406 Unauthorized Messages or Connections TID-408 Unencrypted Sensitive Data Communication TID-411 Weak/Insecure Cryptographic Protocol
CWE weaknesses
CWE-1104 Use of Unmaintained Third Party Components CWE-1188 Insecure Default Initialization of Resource CWE-122 Heap-based Buffer Overflow CWE-125 Out-of-bounds Read CWE-1329 Reliance on Component That is Not Updateable CWE-1390 Weak Authentication CWE-1392 Use of Default Credentials CWE-1395 Dependency on Vulnerable Third-Party Component CWE-200 Exposure of Sensitive Information to an Unauthorized Actor CWE-276 Incorrect Default Permissions CWE-284 Improper Access Control CWE-287 Improper Authentication CWE-294 Authentication Bypass by Capture-replay CWE-306 Missing Authentication for Critical Function CWE-319 Cleartext Transmission of Sensitive Information CWE-321 Use of Hard-coded Cryptographic Key CWE-326 Inadequate Encryption Strength CWE-345 Insufficient Verification of Data Authenticity CWE-353 Missing Support for Integrity Check CWE-427 Uncontrolled Search Path Element CWE-502 Deserialization of Untrusted Data CWE-522 Insufficiently Protected Credentials CWE-639 Authorization Bypass Through User-Controlled Key CWE-787 Out-of-bounds Write CWE-798 Use of Hard-coded Credentials CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') CWE-916 Use of Password Hash With Insufficient Computational Effort