CAM Patch Heart Monitor
Extended-wear cardiac patch monitor. Attributes come from Baxter's own public documentation for this product.
Attributes
Signals
Properties (MITRE EMB3D)
PID-2322 Device deploys an access enforcement/privilege mechanism PID-311 Device includes the usage of a web/HTTP applications PID-33 Device includes interactive applications, services, or user interfaces PID-332 Device includes authenticated services PID-41 Device exposes remote network services PID-411 Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations
Attributes: component types
API Battery Cloud Service Generic Hardware Local Application Local Service Memory Operating System Sensor Modules User Interface Web Application
Attributes: interface types
TCP
Attributes: assets
Patient Data Report Data Sensor Data User Data
Attributes: dataflows
BDxCONNECT to Clinician (CAM Report in PDF) BDxCONNECT to Electronic Health Record (registration, patient diary input, report retrieval) CAM Patch to BDxCONNECT (ECG data upload)
Matched threat intel
Top 20 of 26
Advisories in our coverage that share attributes with this product, strongest first: a named product or component, the same device type or lineage, then the most shared attributes. A shared attribute is a lead, not a finding. The status column shows only what Baxter has said.
| # | Advisory | Date | Shared | Baxter status |
|---|---|---|---|---|
| 1 | A low-privilege user can walk past role limits in Synapse Mobility | Aug 21, 2025 | Same property (MITRE EMB3D)PID-232212 shared attributes: Handles patient data, Web interface, Role-based access, Cloud connectivity +8 | No response from manufacturer |
| 2 | ZOLL Defibrillator Dashboard lets non-admin users upload files that run commands | Jun 10, 2021 | Same property (MITRE EMB3D)PID-23227 shared attributes: Cardiology and implants family, Web interface, File import, Role-based access +3 | No response from manufacturer |
| 3 | Unrestricted file upload on a PACS points straight at code execution | Apr 10, 2025 | Same signals10 shared attributes: File import, Patient or study database, Web interface, Handles patient data +6 | No response from manufacturer |
| 4 | Philips EncoreAnywhere exposes sensitive data in its HTTP headers | May 17, 2018 | Same property (MITRE EMB3D)PID-3115 shared attributes: Cloud connectivity, Web interface, Device includes the usage of a web/HTTP applications (PID-311), Web Application +1 | No response from manufacturer |
| 5 | B. Braun SpaceStation with SpaceCom module has an open redirect in its web server | Mar 23, 2017 | Same property (MITRE EMB3D)PID-3115 shared attributes: Web interface, Device includes the usage of a web/HTTP applications (PID-311), Web Application, Generic Hardware +1 | No response from manufacturer |
| 6 | Change Healthcare PeerVue Web Server leaks technical details in HTTP error messages | Oct 4, 2018 | Same property (MITRE EMB3D)PID-3114 shared attributes: Web interface, Device includes the usage of a web/HTTP applications (PID-311), Web Application, TCP | No response from manufacturer |
| 7 | A 10.0 SQL injection on a patient health portal | Sep 5, 2024 | 12 shared attributesPatient or study database, Handles patient data, Cloud connectivity, Web interface +8 | No response from manufacturer |
| 8 | Dario Health glucose monitoring app and servers exposed cross-user health data | Feb 27, 2025 | 10 shared attributesMonitor, Cloud connectivity, Handles patient data, Web interface +6 | No response from manufacturer |
| 9 | User enumeration on the CareLink Network, found at a conference | Dec 4, 2025 | 9 shared attributesMonitor, Cloud connectivity, Web interface, Handles patient data +5 | No response from manufacturer |
| 10 | Four unpatched flaws disclosed in HAPI FHIR, the server library behind Smile CDR | Oct 22, 2026 | 8 shared attributesDevice exposes remote network services (PID-41), Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations (PID-411), Device includes authenticated services (PID-332), Device deploys an access enforcement/privilege mechanism (PID-2322) +4 | No response from manufacturer |
| 11 | Philips Tasy EMR and WebPortal carry cross-site scripting and information exposure flaws | Apr 30, 2019 | 7 shared attributesWeb interface, HL7 or FHIR integration, Handles patient data, Device includes the usage of a web/HTTP applications (PID-311) +3 | No response from manufacturer |
| 12 | LifePoint Informatics Patient Portal generated lab report PDFs from a URL and a patient ID | Apr 5, 2022 | 8 shared attributesWeb interface, Handles patient data, Cloud connectivity, Patient or study database +4 | No response from manufacturer |
| 13 | OpenClinic GA advisory lists authentication bypass, file upload and SQL abuse flaws | Jul 2, 2020 | 6 shared attributesRole-based access, Patient or study database, File import, Web interface +2 | No response from manufacturer |
| 14 | Innokas VC150 vital signs monitor accepts HL7 injection and stored XSS | Jan 7, 2021 | 6 shared attributesMonitor, HL7 or FHIR integration, Web interface, Device includes the usage of a web/HTTP applications (PID-311) +2 | No response from manufacturer |
| 15 | Medtronic MyCareLink 24950 and 24952 monitors store upload credentials in a recoverable format | Aug 7, 2018 | 7 shared attributesCardiology and implants family, Cardiac, Monitor, Cloud connectivity +3 | No response from manufacturer |
| 16 | Qualcomm Life Capsule products inherit Allegro RomPager cookie flaw scored 9.8 | Aug 28, 2018 | 6 shared attributesWeb interface, Device includes the usage of a web/HTTP applications (PID-311), Local Service, Web Application +2 | No response from manufacturer |
| 17 | Philips Tasy EMR HTML5 has two SQL injection flaws that expose patient data | Nov 4, 2021 | 6 shared attributesPatient or study database, Handles patient data, Web interface, Web Application +2 | No response from manufacturer |
| 18 | CARTO 3 Versions 6 and 7.1 run vulnerable Print Spooler, fixed in Security Service Pack 4 | Nov 23, 2022 | 4 shared attributesCardiology and implants family, Cardiac, Operating System, Local Service | No response from manufacturer |
| 19 | Philips lists IntelliSpace ECG and Trace Master Vue under Chrome ANGLE CVE-2025-6558 | Jul 22, 2025 | 4 shared attributesCardiology and implants family, Web interface, Physiological waveform processing, Local Application | No response from manufacturer |
| 20 | Philips lists IntelliSpace ECG and Trace Master Vue under Chrome V8 CVE-2025-6554 | Jul 15, 2025 | 4 shared attributesCardiology and implants family, Web interface, Physiological waveform processing, Local Application | No response from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-202 Exploitable System Network Stack Component TID-204 Untrusted Programs Can Access Privileged OS Functions TID-205 Existing OS Tools Maliciously Used for Device Manipulation TID-210 Device Vulnerabilities Unpatchable TID-219 OS/Kernel Privilege Escalation TID-221 Authentication Bypass By Message Replay TID-222 Critical System Service May Be Disabled TID-226 Device leaks security information in logs TID-305 Program Executes Dangerous System Calls TID-310 Remotely Accessible Unauthenticated Services TID-311 Default Credentials TID-317 Predictable Cryptographic Key TID-319 Cross Site Scripting (XSS) TID-320 SQL Injection TID-323 Path Traversal TID-324 HTTP Direct Object Reference TID-327 Out of Bounds Memory Access TID-329 Improper Password Storage TID-401 Undocumented Protocol Features TID-405 Network Stack Resource Exhaustion TID-408 Unencrypted Sensitive Data Communication TID-411 Weak/Insecure Cryptographic Protocol
CWE weaknesses
CWE-1104 Use of Unmaintained Third Party Components CWE-1188 Insecure Default Initialization of Resource CWE-1329 Reliance on Component That is Not Updateable CWE-1395 Dependency on Vulnerable Third-Party Component CWE-200 Exposure of Sensitive Information to an Unauthorized Actor CWE-22 Improper Limitation of a Pathname to a Restricted Directory CWE-276 Incorrect Default Permissions CWE-284 Improper Access Control CWE-294 Authentication Bypass by Capture-replay CWE-319 Cleartext Transmission of Sensitive Information CWE-321 Use of Hard-coded Cryptographic Key CWE-326 Inadequate Encryption Strength CWE-427 Uncontrolled Search Path Element CWE-434 Unrestricted Upload of File with Dangerous Type CWE-522 Insufficiently Protected Credentials CWE-639 Authorization Bypass Through User-Controlled Key CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') CWE-916 Use of Password Hash With Insufficient Computational Effort