CoroFlow Cardiovascular System
Coronary physiology measurement system. Attributes come from Abbott's own public documentation for this product.
Attributes
Signals
Properties (MITRE EMB3D)
PID-14 Device includes external peripheral interconnects (e.g., USB, Serial) PID-23 Device includes OS/kernel PID-2322 Device deploys an access enforcement/privilege mechanism PID-31 Application-level software is present and running on the device PID-33 Device includes interactive applications, services, or user interfaces PID-332 Device includes authenticated services PID-34 Device stores logs of application events and information PID-41 Device exposes remote network services PID-411 Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations PID-4113 Device includes cryptographic functions for sensitive data, such as encryption or authentication
Platform
Windows Windows 10
Attributes: materials
Windows 10
Attributes: component types
API Circuit Board Cloud Service Generic Application Generic Hardware Library Local Application Local Service Operating System User Interface Wireless Module
Attributes: interface types
TCP USB Wireless
Attributes: assets
Calibration Data Credentials Log Data Patient Data Sensor Data Software Configuration
Attributes: dataflows
CoroFlow to PACS (physiologic and angiographic data and images via DICOM) CoroFlow to PC clipboard and log file (system use statistics) CoroFlow to USB media or cloud/network storage (measurements and raw waveform data) PressureWire X Guidewire to CoroFlow via Wi-Box (wireless)
Matched threat intel
Top 20 of 156
Advisories in our coverage that share attributes with this product, strongest first: a named product or component, the same device type or lineage, then the most shared attributes. A shared attribute is a lead, not a finding. The status column shows only what Abbott has said.
| # | Advisory | Date | Shared | Abbott status |
|---|---|---|---|---|
| 1 | Philips lists more than 30 products in DejaBlue Remote Desktop advisory | Aug 15, 2019 | Same named componentWindows 10 (= 1703)9 shared attributes: Cardiology and implants family, Named operating system, Remote access, Hospital network +5 | No response from manufacturer |
| 2 | Carestream DirectView and ImageView systems affected by BlueKeep and DejaBlue RDP flaws | May 16, 2019 | Same named componentWindows 10 (= 1607 LTSB)8 shared attributes: Named operating system, Remote access, Hospital network, Device includes OS/kernel (PID-23) +4 | No response from manufacturer |
| 3 | Carestream lists Windows 10 based imaging products as affected by CurveBall CryptoAPI flaw | Jan 17, 2020 | Same named componentWindows 10 (any version)5 shared attributes: Named operating system, Device includes OS/kernel (PID-23), Operating System, Local Application +1 | No response from manufacturer |
| 4 | Siemens Healthineers lists imaging and lab products affected by DejaBlue Remote Desktop flaws | Sep 10, 2019 | Same named componentWindows 10 (= 1703)6 shared attributes: Named operating system, Hospital network, Remote access, Operating System +2 | No response from manufacturer |
| 5 | Philips reviews 70 products for Windows RD Gateway and Remote Desktop Client flaws | Jan 15, 2020 | Same named componentWindows 10 (= 1803)6 shared attributes: Named operating system, Remote access, Operating System, Local Service +2 | No response from manufacturer |
| 6 | Cepheid GeneXpert Dx 6.4a needs Windows 10 update KB5068781 for 32 CVEs | Mar 12, 2026 | Same named componentWindows 10 (= 21H2)5 shared attributes: Named operating system, Hospital network, Device includes OS/kernel (PID-23), Operating System +1 | No response from manufacturer |
| 7 | Philips names ten product lines in Windows Task Scheduler CVE-2024-49039 notice | Nov 18, 2024 | Same named componentWindows 10 (= 1809)4 shared attributes: Cardiology and implants family, Named operating system, Hospital network, Operating System | No response from manufacturer |
| 8 | Cepheid GeneXpert Xpress 6.4a ships without Windows speculative execution mitigations | Mar 11, 2026 | Same named componentWindows 10 (= 21H2 / 22H2)4 shared attributes: Named operating system, Device includes OS/kernel (PID-23), Operating System, Software Configuration | No response from manufacturer |
| 9 | BD lists Pyxis, Alaris and lab systems in scope for DejaBlue Remote Desktop flaws | Oct 30, 2019 | Same named componentWindows 10 (= 1703)5 shared attributes: Remote access, Named operating system, Operating System, Local Service +1 | No response from manufacturer |
| 10 | Philips lists 26 products running Windows under the CryptoAPI spoofing flaw CVE-2020-0601 | Jan 16, 2020 | Same named componentWindows 10 (= 1803)3 shared attributes: Cardiology and implants family, Named operating system, Operating System | No response from manufacturer |
| 11 | Philips lists IntelliSpace PACS, UroNav and PICiX under Windows RPC flaws CVE-2023-21708 and CVE-2023-23405 | Mar 22, 2023 | Same named componentWindows 10 (range 10.0.0)3 shared attributes: Named operating system, Operating System, Library | No response from manufacturer |
| 12 | BD lists FocalPoint, Kiestra and BD MAX in scope for three Remote Desktop flaws | Apr 3, 2020 | Same named componentWindows 10 (= 1803)4 shared attributes: Remote access, Operating System, Local Service, TCP | No response from manufacturer |
| 13 | BD lists FACS, Pyxis and Kiestra products in scope for Win32k zero-day CVE-2021-1732 | Jul 29, 2021 | Same named componentWindows 10 (= 1803)3 shared attributes: Named operating system, Operating System, Local Application | No response from manufacturer |
| 14 | BD tests Microsoft's Bad Neighbor patch for FACS, Pyxis and Rowa products | Dec 3, 2020 | Same named componentWindows 10 (= 1803)2 shared attributes: Named operating system, Operating System | No response from manufacturer |
| 15 | Philips lists Capsule Neuron under Windows PEAP denial of service CVE-2023-21701 | Mar 29, 2023 | Same named componentWindows 10 (range 10.0.0)2 shared attributes: Wireless connectivity, Wireless | No response from manufacturer |
| 16 | BD tests Microsoft fix for CryptoAPI spoofing flaw CVE-2020-0601 | Jan 31, 2020 | Same named componentWindows 10 (= 1803)1 shared attribute: Operating System | No response from manufacturer |
| 17 | Canon Medical says CT, MR, VL and XR systems may be exposed to RPC runtime flaw CVE-2022-26809 | Jul 4, 2022 | Same named componentWindows 10 (range 10.0.0)1 shared attribute: TCP | No response from manufacturer |
| 18 | Compounding software that did not encrypt its database traffic by default | May 15, 2026 | Same property (MITRE EMB3D)PID-411312 shared attributes: Patient or study database, Handles patient data, Remote access, User accounts +8 | No response from manufacturer |
| 19 | BD Alaris 8015 PC unit exposes stored Wi-Fi credentials on its removable flash card | Jan 17, 2017 | Same property (MITRE EMB3D)PID-41138 shared attributes: Removable media, Wireless connectivity, Hospital network, Generic Hardware +4 | No response from manufacturer |
| 20 | Philips IntelliSpace Cardiovascular and Xcelera store credentials in cleartext | Nov 14, 2017 | Same property (MITRE EMB3D)PID-349 shared attributes: Cardiology and implants family, User accounts, Handles patient data, DICOM or image parsing +5 | No response from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-103 Microarchitectural Side Channels TID-107 Unauthorized Direct Memory Access (DMA) TID-108 ROM/NVRAM Data Extraction or Modification TID-111 Untrusted External Storage TID-115 Firmware/Data Extraction via Hardware Interface TID-116 Latent Privileged Access Port TID-119 Latent Hardware Debug Port Allows Memory/Code Manipulation TID-202 Exploitable System Network Stack Component TID-204 Untrusted Programs Can Access Privileged OS Functions TID-205 Existing OS Tools Maliciously Used for Device Manipulation TID-208 Virtual Machine Escape TID-210 Device Vulnerabilities Unpatchable TID-211 Device Allows Unauthenticated Firmware Installation TID-213 Faulty FW/SW Update Integrity Verification TID-215 Unencrypted SW/FW Updates TID-219 OS/Kernel Privilege Escalation TID-221 Authentication Bypass By Message Replay TID-222 Critical System Service May Be Disabled TID-224 Excessive Access via Software Diagnostic Features TID-225 Logs can be manipulated on the device TID-226 Device leaks security information in logs TID-301 Applications Binaries Modified TID-303 Excessive Trust in Offboard Management/IDE Software TID-305 Program Executes Dangerous System Calls TID-310 Remotely Accessible Unauthenticated Services TID-311 Default Credentials TID-313 Unauthenticated Session Changes Credential TID-314 Passwords Can Be Guessed Using Brute-Force Attempts TID-316 Incorrect Certificate Verification Allows Authentication Bypass TID-317 Predictable Cryptographic Key TID-318 Insecure Cryptographic Implementation TID-319 Cross Site Scripting (XSS) TID-320 SQL Injection TID-323 Path Traversal TID-324 HTTP Direct Object Reference TID-326 Insecure Deserialization TID-327 Out of Bounds Memory Access TID-328 Hardcoded Credentials TID-329 Improper Password Storage TID-404 Remotely Triggerable Deadlock/DoS TID-405 Network Stack Resource Exhaustion TID-406 Unauthorized Messages or Connections TID-407 Missing Message Replay Protection TID-408 Unencrypted Sensitive Data Communication TID-411 Weak/Insecure Cryptographic Protocol
CWE weaknesses
CWE-1104 Use of Unmaintained Third Party Components CWE-1188 Insecure Default Initialization of Resource CWE-1191 On-Chip Debug and Test Interface With Improper Access Control CWE-1313 Hardware Allows Activation of Test or Debug Logic at Runtime CWE-1329 Reliance on Component That is Not Updateable CWE-1390 Weak Authentication CWE-1392 Use of Default Credentials CWE-1395 Dependency on Vulnerable Third-Party Component CWE-20 Improper Input Validation CWE-200 Exposure of Sensitive Information to an Unauthorized Actor CWE-22 Improper Limitation of a Pathname to a Restricted Directory CWE-276 Incorrect Default Permissions CWE-284 Improper Access Control CWE-287 Improper Authentication CWE-290 Authentication Bypass by Spoofing CWE-294 Authentication Bypass by Capture-replay CWE-306 Missing Authentication for Critical Function CWE-319 Cleartext Transmission of Sensitive Information CWE-321 Use of Hard-coded Cryptographic Key CWE-326 Inadequate Encryption Strength CWE-345 Insufficient Verification of Data Authenticity CWE-400 Uncontrolled Resource Consumption CWE-427 Uncontrolled Search Path Element CWE-434 Unrestricted Upload of File with Dangerous Type CWE-476 NULL Pointer Dereference CWE-494 Download of Code Without Integrity Check CWE-502 Deserialization of Untrusted Data CWE-522 Insufficiently Protected Credentials CWE-639 Authorization Bypass Through User-Controlled Key CWE-798 Use of Hard-coded Credentials CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') CWE-916 Use of Password Hash With Insufficient Computational Effort