Similar Products
Stored passwords recoverable in a Siemens imaging platform. Products whose own public documentation makes them the same type of product as the one this advisory names, gives them the attack surface the flaw needs, or both. Within each group a named product or component and the same device type or lineage come first, then the most shared attributes, rarer ones counting for more.
This advisory's attributes
Ranked products
Two reasons a product is similar. The same type of product: a peer of the product this advisory names, whatever technology it uses. The same attack surface: any product whose documentation states what this flaw needs. A product with both comes first. Other shared attributes lists products that overlap on attributes but have not been scored on either reason. A shared attribute is a lead, not a finding. The status column shows only what each manufacturer has said.
| # | Product | Match | Shared attributes | Manufacturer status |
|---|---|---|---|---|
| 1 | Infinity CentralStation WideDräger, Monitor, Physiological, Patient(With Arrhythmia Detection Or Alarms) | Same property (MITRE EMB3D)PID-33217 shared attributes | SignalUser accounts Handles patient data Hospital network PropertyDevice includes passwords to authenticate the users (PID-3321) Device includes cryptographic functions for sensitive data, such as encryption or authentication (PID-4113) Application-level software is present and running on the device (PID-31) AssetCredentials | No response from manufacturer |
| 2 | LOGIQ eGE HealthCare, System, Imaging, Pulsed Doppler, Ultrasonic | Exposed to the same EMB3D threatTID-3298 shared attributes | Device typeimaging family SignalUser accounts Handles patient data Hospital network PropertyApplication-level software is present and running on the device (PID-31) Device includes support for firmware/software updates (PID-27) Device includes interactive applications, services, or user interfaces (PID-33) AssetCredentials | No response from manufacturer |
| 3 | Dexcom G6 Continuous Glucose Monitoring (CGM) SystemDexCom, Integrated Continuous Glucose Monitoring System, Factory Calibrated | Exposed to the same EMB3D threatTID-2216 shared attributes | SignalUser accounts Remote access Handles patient data PropertyDevice includes cryptographic functions for sensitive data, such as encryption or authentication (PID-4113) Application-level software is present and running on the device (PID-31) Device includes interactive applications, services, or user interfaces (PID-33) | No response from manufacturer |
| 4 | ART-Plan+TheraPanacea, System, Planning, Radiation Therapy Treatment | Same signals6 shared attributes | SignalUser accounts Role-based access Handles patient data Hospital network PropertyApplication-level software is present and running on the device (PID-31) Device includes interactive applications, services, or user interfaces (PID-33) | No response from manufacturer |
| 5 | TipTraQPranaq, Ventilatory Effort Recorder | Exposed to the same EMB3D threatTID-3295 shared attributes | SignalUser accounts Web interface PropertyApplication-level software is present and running on the device (PID-31) Device includes interactive applications, services, or user interfaces (PID-33) AssetCredentials | No response from manufacturer |
| 6 | da Vinci Xi Surgical System, da Vinci X Surgical SystemIntuitive, System, Surgical, Computer Controlled Instrument | Exposed to the same EMB3D threatTID-3294 shared attributes | SignalUser accounts Remote access PropertyApplication-level software is present and running on the device (PID-31) Device includes interactive applications, services, or user interfaces (PID-33) | No response from manufacturer |
| # | Product | Match | Shared attributes | Manufacturer status |
|---|---|---|---|---|
| 1 | Vscan AirGE HealthCare, System, Imaging, Pulsed Doppler, Ultrasonic | 12 shared attributes | Device typeimaging family SignalUser accounts Role-based access Remote access Handles patient data Hospital network Web interface PropertyDevice includes cryptographic functions for sensitive data, such as encryption or authentication (PID-4113) Application-level software is present and running on the device (PID-31) Device includes support for firmware/software updates (PID-27) Device includes interactive applications, services, or user interfaces (PID-33) AssetCredentials | No response from manufacturer |
| 2 | TheraSphere 360 Y-90 Management PlatformBoston Scientific, System, Image Processing, Radiological | 9 shared attributes | Device typeimaging family image SignalUser accounts Remote access Handles patient data Web interface PropertyApplication-level software is present and running on the device (PID-31) Device includes interactive applications, services, or user interfaces (PID-33) AssetCredentials | No response from manufacturer |
| 3 | MOBILETT ImpactSiemens Healthineers, System, X-Ray, Mobile | 8 shared attributes | Device typeimaging family SignalUser accounts Role-based access Handles patient data Hospital network PropertyDevice includes cryptographic functions for sensitive data, such as encryption or authentication (PID-4113) Application-level software is present and running on the device (PID-31) Device includes interactive applications, services, or user interfaces (PID-33) | No response from manufacturer |
| 4 | Harmony Referral SystemTopcon Healthcare, System, Image Management, Ophthalmic | 9 shared attributes | Device typeimaging family image SignalRemote access Handles patient data Hospital network Web interface PropertyDevice includes cryptographic functions for sensitive data, such as encryption or authentication (PID-4113) Application-level software is present and running on the device (PID-31) Device includes interactive applications, services, or user interfaces (PID-33) | No response from manufacturer |
| 5 | Infinity Gateway SuiteDräger, System, Network And Communication, Physiological Monitors | 8 shared attributes | SignalUser accounts Remote access Handles patient data Hospital network PropertyDevice includes cryptographic functions for sensitive data, such as encryption or authentication (PID-4113) Application-level software is present and running on the device (PID-31) Device includes interactive applications, services, or user interfaces (PID-33) AssetCredentials | No response from manufacturer |
| 6 | Philips IntelliSpace CardiovascularPhilips, System, Image Processing, Radiological | 8 shared attributes | Device typeimage SignalUser accounts Remote access Handles patient data Hospital network PropertyDevice includes cryptographic functions for sensitive data, such as encryption or authentication (PID-4113) Application-level software is present and running on the device (PID-31) Device includes interactive applications, services, or user interfaces (PID-33) | No response from manufacturer |
| 7 | CT Collaboration LivePhilips, System, Image Processing, Radiological | 7 shared attributes | Device typeimaging family image SignalRole-based access Remote access Hospital network PropertyApplication-level software is present and running on the device (PID-31) Device includes interactive applications, services, or user interfaces (PID-33) | No response from manufacturer |
| 8 | BD Alaris Infusion System with Guardrails Suite MXBD, Pump, Infusion | 6 shared attributes | SignalUser accounts Role-based access Hospital network PropertyApplication-level software is present and running on the device (PID-31) Device includes interactive applications, services, or user interfaces (PID-33) AssetCredentials | No response from manufacturer |
| 9 | Synapse PACSFujifilm Healthcare, Automated Radiological Image Processing Software | 8 shared attributes | Device typeimaging family pac image SignalHandles patient data Hospital network Web interface PropertyApplication-level software is present and running on the device (PID-31) Device includes interactive applications, services, or user interfaces (PID-33) | No response from manufacturer |
| 10 | Image Management V15Philips, System, Image Processing, Radiological | 8 shared attributes | Device typeimaging family image SignalRemote access Handles patient data Hospital network Web interface PropertyApplication-level software is present and running on the device (PID-31) Device includes interactive applications, services, or user interfaces (PID-33) | No response from manufacturer |
| 11 | Image SuiteCarestream Health, System, Image Processing, Radiological | 8 shared attributes | Device typeimaging family image SignalHandles patient data Hospital network Web interface PropertyApplication-level software is present and running on the device (PID-31) Device includes support for firmware/software updates (PID-27) Device includes interactive applications, services, or user interfaces (PID-33) | No response from manufacturer |
| 12 | ViewPoint 6GE HealthCare, System, Image Processing, Radiological | 7 shared attributes | Device typeimaging family image SignalRole-based access Handles patient data Hospital network PropertyApplication-level software is present and running on the device (PID-31) Device includes interactive applications, services, or user interfaces (PID-33) | No response from manufacturer |
| 13 | BlueStar and BlueStar RxWelldoc, Calculator, Drug Dose | 6 shared attributes | SignalUser accounts Handles patient data Web interface PropertyApplication-level software is present and running on the device (PID-31) Device includes interactive applications, services, or user interfaces (PID-33) AssetCredentials | No response from manufacturer |
| 14 | Syngo Carbon Space VA20ASiemens Healthineers, System, Image Processing, Radiological | 7 shared attributes | Device typeimaging family image SignalHandles patient data Hospital network Web interface PropertyApplication-level software is present and running on the device (PID-31) Device includes interactive applications, services, or user interfaces (PID-33) | No response from manufacturer |
| 15 | Syngo Carbon Enterprise AccessSiemens Healthineers, System, Image Processing, Radiological | 7 shared attributes | Device typeimaging family image SignalHandles patient data Hospital network Web interface PropertyApplication-level software is present and running on the device (PID-31) Device includes interactive applications, services, or user interfaces (PID-33) | No response from manufacturer |
| 16 | Syngo Carbon Space VA30ASiemens Healthineers, System, Image Processing, Radiological | 7 shared attributes | Device typeimaging family image SignalHandles patient data Hospital network Web interface PropertyApplication-level software is present and running on the device (PID-31) Device includes interactive applications, services, or user interfaces (PID-33) | No response from manufacturer |
| 17 | aPROMISE XExini Diagnostics, System, Image Processing, Radiological | 7 shared attributes | Device typeimaging family image SignalHandles patient data Hospital network Web interface PropertyApplication-level software is present and running on the device (PID-31) Device includes interactive applications, services, or user interfaces (PID-33) | No response from manufacturer |
| 18 | Arthrex Virtual Implant Positioning (VIP) SystemArthrex, Shoulder Arthroplasty Implantation System | 5 shared attributes | SignalUser accounts Handles patient data Web interface PropertyApplication-level software is present and running on the device (PID-31) AssetCredentials | No response from manufacturer |
| 19 | qXR-DetectQure.ai, Analyzer, Medical Image | 5 shared attributes | Device typeimaging family image SignalHospital network PropertyDevice includes cryptographic functions for sensitive data, such as encryption or authentication (PID-4113) Application-level software is present and running on the device (PID-31) | No response from manufacturer |
| 20 | syngo.via View&GO VA40ASiemens Healthineers, System, Image Processing, Radiological | 7 shared attributes | Device typeimaging family image SignalHandles patient data Hospital network PropertyApplication-level software is present and running on the device (PID-31) Device includes support for firmware/software updates (PID-27) Device includes interactive applications, services, or user interfaces (PID-33) | No response from manufacturer |
| 21 | syngo.via View&GOSiemens Healthineers, System, Image Processing, Radiological | 7 shared attributes | Device typeimaging family image SignalHandles patient data Hospital network PropertyApplication-level software is present and running on the device (PID-31) Device includes support for firmware/software updates (PID-27) Device includes interactive applications, services, or user interfaces (PID-33) | No response from manufacturer |
| 22 | EchoPAC Software Only / EchoPAC Plug-inGE HealthCare, Automated Radiological Image Processing Software | 7 shared attributes | Device typeimaging family image SignalHandles patient data Hospital network PropertyApplication-level software is present and running on the device (PID-31) Device includes support for firmware/software updates (PID-27) Device includes interactive applications, services, or user interfaces (PID-33) | No response from manufacturer |
| 23 | ACUSON Sequoia Diagnostic Ultrasound SystemSiemens Healthineers, System, Imaging, Pulsed Doppler, Ultrasonic | 7 shared attributes | Device typeimaging family SignalRemote access Handles patient data Hospital network PropertyApplication-level software is present and running on the device (PID-31) Device includes support for firmware/software updates (PID-27) Device includes interactive applications, services, or user interfaces (PID-33) | No response from manufacturer |
| 24 | qCT LN QuantQure.ai, Automated Radiological Image Processing Software | 6 shared attributes | Device typeimaging family image SignalHospital network Web interface PropertyApplication-level software is present and running on the device (PID-31) Device includes interactive applications, services, or user interfaces (PID-33) | No response from manufacturer |
| 25 | Aperio GT 450 DXLeica Biosystems, Whole Slide Imaging System | 6 shared attributes | Device typeimaging family SignalRemote access Hospital network Web interface PropertyApplication-level software is present and running on the device (PID-31) Device includes interactive applications, services, or user interfaces (PID-33) | No response from manufacturer |