Vibe SF Self-Fitting Hearing Aid
Self-Fitting Air-Conduction Hearing Aid, Prescription. Attributes come from WS Audiology's own public documentation for this product.
Attributes
Signals
Properties (MITRE EMB3D)
Platform
Android iOS
Attributes: component types
Battery Generic Application Local Application Operating System User Interface Web Application
Attributes: interface types
Bluetooth Wireless
Matched threat intel
26
Advisories in our coverage that share an attribute with this product. A shared attribute is a lead, not a finding. The status column shows only what WS Audiology has said.
| Advisory | Date | Shared | WS Audiology status |
|---|---|---|---|
| Path traversal in Thermo Fisher's Torrent Suite lets authenticated users read server files | Oct 15, 2026 | Same property (MITRE EMB3D)PID-311 | No feedback feed from manufacturer |
| EMS patient-care app reflects unsanitized input into a WebView | Feb 10, 2026 | Same property (MITRE EMB3D)PID-311 | No feedback feed from manufacturer |
| User enumeration on the CareLink Network, found at a conference | Dec 4, 2025 | Same property (MITRE EMB3D)PID-311 | No feedback feed from manufacturer |
| A hospital management backend leaked its own system information | Oct 28, 2025 | Same property (MITRE EMB3D)PID-311 | No feedback feed from manufacturer |
| A low-privilege user can walk past role limits in Synapse Mobility | Aug 21, 2025 | Same property (MITRE EMB3D)PID-311 | No feedback feed from manufacturer |
| Five flaws in Sante PACS Server, and one sends credentials in cleartext | Aug 12, 2025 | Same property (MITRE EMB3D)PID-311 | No feedback feed from manufacturer |
| Dario Health glucose monitoring app and servers exposed cross-user health data | Feb 27, 2025 | Same property (MITRE EMB3D)PID-311 | No feedback feed from manufacturer |
| A 10.0 SQL injection on a patient health portal | Sep 5, 2024 | Same property (MITRE EMB3D)PID-311 | No feedback feed from manufacturer |
| LifePoint Informatics Patient Portal generated lab report PDFs from a URL and a patient ID | Apr 5, 2022 | Same property (MITRE EMB3D)PID-311 | No feedback feed from manufacturer |
| Philips Tasy EMR HTML5 has two SQL injection flaws that expose patient data | Nov 4, 2021 | Same property (MITRE EMB3D)PID-311 | No feedback feed from manufacturer |
| Innokas VC150 vital signs monitor accepts HL7 injection and stored XSS | Jan 7, 2021 | Same property (MITRE EMB3D)PID-311 | No feedback feed from manufacturer |
| Philips Clinical Collaboration Platform 12.2.1 and earlier has five web and authentication flaws | Sep 17, 2020 | Same property (MITRE EMB3D)PID-311 | No feedback feed from manufacturer |
| Philips IntelliVue monitors and PIC iX skip certificate revocation and crash on bad input | Sep 10, 2020 | Same property (MITRE EMB3D)PID-311 | No feedback feed from manufacturer |
| Philips Tasy EMR and WebPortal carry cross-site scripting and information exposure flaws | Apr 30, 2019 | Same property (MITRE EMB3D)PID-311 | No feedback feed from manufacturer |
| Change Healthcare PeerVue Web Server leaks technical details in HTTP error messages | Oct 4, 2018 | Same property (MITRE EMB3D)PID-311 | No feedback feed from manufacturer |
| BeaconMedaes TotalAlert Scroll Medical Air Systems expose stored passwords to unauthenticated users | May 24, 2018 | Same property (MITRE EMB3D)PID-311 | No feedback feed from manufacturer |
| Philips EncoreAnywhere exposes sensitive data in its HTTP headers | May 17, 2018 | Same property (MITRE EMB3D)PID-311 | No feedback feed from manufacturer |
| B. Braun SpaceStation with SpaceCom module has an open redirect in its web server | Mar 23, 2017 | Same property (MITRE EMB3D)PID-311 | No feedback feed from manufacturer |
| Mira’s cloud login accepted any password and returned a session token | Aug 11, 2026 | Same platformAndroid 4.5 | No feedback feed from manufacturer |
| Unauthenticated SQL injection into an imaging database, base score 9.8 | Dec 6, 2024 | Exposed to the same EMB3D threatTID-320 | No feedback feed from manufacturer |
| Softneta MedDream PACS allows unauthenticated remote code execution | Sep 5, 2023 | Exposed to the same EMB3D threatTID-324 | No feedback feed from manufacturer |
| BD Synapsys sessions did not expire, risking changes to patient data | May 31, 2022 | Exposed to the same EMB3D threatTID-321 | No feedback feed from manufacturer |
| Philips Gemini PET/CT systems write sensitive data to removable media without access control | Mar 25, 2021 | Exposed to the same EMB3D threatTID-324 | No feedback feed from manufacturer |
| OpenClinic GA advisory lists authentication bypass, file upload and SQL abuse flaws | Jul 2, 2020 | Exposed to the same EMB3D threatTID-319 | No feedback feed from manufacturer |
| Roche Accu-Chek and CoaguChek point of care handhelds expose a weakly protected service interface | Nov 6, 2018 | Exposed to the same EMB3D threatTID-324 | No feedback feed from manufacturer |
| Medtronic 2090 CareLink and 29901 Encore programmers accept updates without verifying their origin | Feb 27, 2018 | Exposed to the same EMB3D threatTID-323 | No feedback feed from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-211 Device Allows Unauthenticated Firmware Installation TID-213 Faulty FW/SW Update Integrity Verification TID-215 Unencrypted SW/FW Updates TID-221 Authentication Bypass By Message Replay TID-222 Critical System Service May Be Disabled TID-226 Device leaks security information in logs TID-310 Remotely Accessible Unauthenticated Services TID-311 Default Credentials TID-313 Unauthenticated Session Changes Credential TID-314 Passwords Can Be Guessed Using Brute-Force Attempts TID-316 Incorrect Certificate Verification Allows Authentication Bypass TID-317 Predictable Cryptographic Key TID-319 Cross Site Scripting (XSS) TID-320 SQL Injection TID-323 Path Traversal TID-324 HTTP Direct Object Reference TID-328 Hardcoded Credentials TID-329 Improper Password Storage TID-401 Undocumented Protocol Features TID-404 Remotely Triggerable Deadlock/DoS TID-405 Network Stack Resource Exhaustion TID-406 Unauthorized Messages or Connections TID-408 Unencrypted Sensitive Data Communication TID-411 Weak/Insecure Cryptographic Protocol
CWE weaknesses
CWE-1188 Insecure Default Initialization of Resource CWE-1390 Weak Authentication CWE-20 Improper Input Validation CWE-200 Exposure of Sensitive Information to an Unauthorized Actor CWE-276 Incorrect Default Permissions CWE-284 Improper Access Control CWE-287 Improper Authentication CWE-294 Authentication Bypass by Capture-replay CWE-306 Missing Authentication for Critical Function CWE-319 Cleartext Transmission of Sensitive Information CWE-321 Use of Hard-coded Cryptographic Key CWE-326 Inadequate Encryption Strength CWE-345 Insufficient Verification of Data Authenticity CWE-400 Uncontrolled Resource Consumption CWE-476 NULL Pointer Dereference CWE-494 Download of Code Without Integrity Check CWE-639 Authorization Bypass Through User-Controlled Key CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') CWE-916 Use of Password Hash With Insufficient Computational Effort