t:slim X2 Insulin Pump
Automated insulin delivery pump. Attributes come from Tandem Diabetes Care's own public documentation for this product.
Attributes
Signals
Properties (MITRE EMB3D)
PID-14 Device includes external peripheral interconnects (e.g., USB, Serial) PID-27 Device includes support for firmware/software updates PID-275 Device includes remotely-initiated firmware/software updates PID-33 Device includes interactive applications, services, or user interfaces PID-41 Device exposes remote network services PID-411 Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations
Platform
Android companion app: Android app Android
Attributes: component types
API Battery Circuit Board Cloud Application Display Firmware Local Application Local Service Mobile Application Pump User Interface
Attributes: interface types
Bluetooth USB Wireless
Attributes: assets
Patient Data Software Configuration Software Update
Attributes: dataflows
CGM to Pump (sensor values) Mobile App to Pump (bolus request, stop, cancel) Mobile App to Tandem Source (pump and CGM data upload) Pump to Mobile App (pump and CGM data, alerts and alarms) Tandem Source to Pump via personal computer (remote software update)
Matched threat intel
Top 20 of 40
Advisories in our coverage that share attributes with this product, strongest first: a named product or component, the same device type or lineage, then the most shared attributes. A shared attribute is a lead, not a finding. The status column shows only what Tandem Diabetes Care has said.
| # | Advisory | Date | Shared | Tandem Diabetes Care status |
|---|---|---|---|---|
| 1 | Flow Neuroscience FL-100 ships a shared Bluetooth credential in every unit | Aug 13, 2026 | Same property (MITRE EMB3D)PID-41113 shared attributes: Wireless connectivity, User accounts, Therapy delivery, Field-updatable firmware +9 | No response from manufacturer |
| 2 | A DICOM viewer that did not check its update server certificate | Feb 20, 2025 | Same property (MITRE EMB3D)PID-27512 shared attributes: Field-updatable firmware, Cloud connectivity, User accounts, Handles patient data +8 | No response from manufacturer |
| 3 | Medtronic 2090 CareLink and 29901 Encore programmers accept updates without verifying their origin | Feb 27, 2018 | Same property (MITRE EMB3D)PID-2757 shared attributes: Field-updatable firmware, Cloud connectivity, USB port, Device includes support for firmware/software updates (PID-27) +3 | No response from manufacturer |
| 4 | Baxter Sigma Spectrum wireless battery modules keep Wi-Fi credentials unencrypted and skip server authentication | Sep 8, 2022 | Same property (MITRE EMB3D)PID-4119 shared attributes: Infusion and medication family, Pump, Wireless connectivity, Therapy delivery +5 | No response from manufacturer |
| 5 | MicroDicom DICOM Viewer 2024.03 fails to validate its update server certificate | Feb 6, 2025 | Same property (MITRE EMB3D)PID-2754 shared attributes: Field-updatable firmware, Device includes support for firmware/software updates (PID-27), Local Application, Software Update | No response from manufacturer |
| 6 | BPL PWS-01-BT weighing scale sends unencrypted, unauthenticated BLE data to the Be Well app | Sep 10, 2024 | Same platformAndroid app3 shared attributes: Wireless connectivity, Mobile app, Mobile Application | No response from manufacturer |
| 7 | Philips HealthSuite Health Android app uses encryption too weak for its data | Dec 6, 2018 | Same platformAndroid app3 shared attributes: Mobile app, Handles patient data, Mobile Application | No response from manufacturer |
| 8 | Mira’s cloud login accepted any password and returned a session token | Aug 11, 2026 | 15 shared attributesHandles patient data, Cloud connectivity, User accounts, Remote access +11 | No response from manufacturer |
| 9 | Hidden BLE commands can switch off a vagus nerve stimulator’s safety limits | Aug 11, 2026 | 13 shared attributesWireless connectivity, Therapy delivery, User accounts, Field-updatable firmware +9 | No response from manufacturer |
| 10 | Baxter Sigma Spectrum infusion pumps and wireless battery modules carry hard-coded passwords | Jun 18, 2020 | 13 shared attributesInfusion and medication family, Pump, Therapy delivery, Wireless connectivity +9 | No response from manufacturer |
| 11 | B. Braun SpaceCom and Battery Pack SP with Wi-Fi carry 11 flaws from XSS to unsigned firmware | Oct 22, 2020 | 10 shared attributesInfusion and medication family, Pump, Wireless connectivity, Field-updatable firmware +6 | No response from manufacturer |
| 12 | SOOIL Dana Diabecare RS insulin pump and apps can be spoofed and bypassed over Bluetooth | Jan 12, 2021 | 11 shared attributesInfusion and medication family, Insulin, Pump, Therapy delivery +7 | No response from manufacturer |
| 13 | Missing authentication lets an attacker rewrite a cardiac wearable | May 28, 2026 | 12 shared attributesWireless connectivity, Handles patient data, User accounts, Mobile app +8 | No response from manufacturer |
| 14 | A hard-coded VNC password on a bioreactor, base score 9.8 | May 26, 2026 | 13 shared attributesRemote access, User accounts, Wireless connectivity, Therapy delivery +9 | No response from manufacturer |
| 15 | A heart pump controller drew a Class I recall with no attacker in sight | Oct 14, 2025 | 10 shared attributesInfusion and medication family, Pump, Therapy delivery, Remote access +6 | No response from manufacturer |
| 16 | Baxter ExactaMix compounders carry hard-coded admin credentials and send orders in clear text | Jun 18, 2020 | 11 shared attributesInfusion and medication family, Automated, User accounts, USB port +7 | No response from manufacturer |
| 17 | Abbott ICDs and CRT-Ds allow RF authentication bypass and battery drain | Apr 17, 2018 | 10 shared attributesWireless connectivity, Therapy delivery, Field-updatable firmware, Remote access +6 | No response from manufacturer |
| 18 | BD Alaris System with Guardrails Suite MX has unsigned wireless firmware and tamperable datasets | Jul 13, 2023 | 10 shared attributesInfusion and medication family, Pump, Field-updatable firmware, Therapy delivery +6 | No response from manufacturer |
| 19 | Medtronic MyCareLink Smart 25000 reader allows Bluetooth authentication bypass and unsigned firmware | Dec 10, 2020 | 9 shared attributesWireless connectivity, Mobile app, Field-updatable firmware, Cloud connectivity +5 | No response from manufacturer |
| 20 | Abbott Accent, Anthem, Assurity and Allure pacemakers get firmware fix for RF authentication bypass | Aug 29, 2017 | 11 shared attributesWireless connectivity, Therapy delivery, Field-updatable firmware, Handles patient data +7 | No response from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-103 Microarchitectural Side Channels TID-108 ROM/NVRAM Data Extraction or Modification TID-111 Untrusted External Storage TID-115 Firmware/Data Extraction via Hardware Interface TID-116 Latent Privileged Access Port TID-119 Latent Hardware Debug Port Allows Memory/Code Manipulation TID-202 Exploitable System Network Stack Component TID-204 Untrusted Programs Can Access Privileged OS Functions TID-205 Existing OS Tools Maliciously Used for Device Manipulation TID-210 Device Vulnerabilities Unpatchable TID-211 Device Allows Unauthenticated Firmware Installation TID-213 Faulty FW/SW Update Integrity Verification TID-215 Unencrypted SW/FW Updates TID-219 OS/Kernel Privilege Escalation TID-221 Authentication Bypass By Message Replay TID-222 Critical System Service May Be Disabled TID-224 Excessive Access via Software Diagnostic Features TID-305 Program Executes Dangerous System Calls TID-310 Remotely Accessible Unauthenticated Services TID-311 Default Credentials TID-313 Unauthenticated Session Changes Credential TID-314 Passwords Can Be Guessed Using Brute-Force Attempts TID-316 Incorrect Certificate Verification Allows Authentication Bypass TID-317 Predictable Cryptographic Key TID-318 Insecure Cryptographic Implementation TID-319 Cross Site Scripting (XSS) TID-321 HTTP Application Session Hijacking TID-323 Path Traversal TID-327 Out of Bounds Memory Access TID-328 Hardcoded Credentials TID-329 Improper Password Storage TID-401 Undocumented Protocol Features TID-404 Remotely Triggerable Deadlock/DoS TID-406 Unauthorized Messages or Connections TID-407 Missing Message Replay Protection TID-408 Unencrypted Sensitive Data Communication TID-411 Weak/Insecure Cryptographic Protocol
CWE weaknesses
CWE-1104 Use of Unmaintained Third Party Components CWE-1188 Insecure Default Initialization of Resource CWE-1191 On-Chip Debug and Test Interface With Improper Access Control CWE-1313 Hardware Allows Activation of Test or Debug Logic at Runtime CWE-1329 Reliance on Component That is Not Updateable CWE-1390 Weak Authentication CWE-1392 Use of Default Credentials CWE-1395 Dependency on Vulnerable Third-Party Component CWE-22 Improper Limitation of a Pathname to a Restricted Directory CWE-276 Incorrect Default Permissions CWE-287 Improper Authentication CWE-290 Authentication Bypass by Spoofing CWE-294 Authentication Bypass by Capture-replay CWE-306 Missing Authentication for Critical Function CWE-319 Cleartext Transmission of Sensitive Information CWE-321 Use of Hard-coded Cryptographic Key CWE-326 Inadequate Encryption Strength CWE-345 Insufficient Verification of Data Authenticity CWE-427 Uncontrolled Search Path Element CWE-434 Unrestricted Upload of File with Dangerous Type CWE-494 Download of Code Without Integrity Check CWE-522 Insufficiently Protected Credentials CWE-798 Use of Hard-coded Credentials CWE-916 Use of Password Hash With Insufficient Computational Effort