A proposed class action accuses University Hospitals of negligence after an October 22 cyberattack that took its MyChart portal offline; the Cleveland patient's suit, filed October 28, claims more than a million records were exposed, a number University Hospitals has not confirmed. University of New Mexico Health Sciences Center disclosed a cyberattack October 26 that diverted ambulances for about two hours; the BYOD extortion group claims it compromised 36,000 systems, a figure UNM has not confirmed. Philips updated its Node2Shell advisory October 27 for CVE-2026-111497, the Node.js Brotli decoder flaw it first flagged October 26 against PIC iX 4.x; the advisory still names no impacted products or fixed version. Philips updated its PHP2Shell advisory October 27 for CVE-2026-109618 and CVE-2026-109619, adding five more affected products including IntelliSpace Portal V12 and Philips Axon to the seven already listed. NorthShore Health Centers disclosed a data breach to patients October 27, one of several Midwest provider notifications issued that week. Denver Health Medical Plan notified more than 238,000 members October 26 about a vendor-related data incident. A proposed class action accuses University Hospitals of negligence after an October 22 cyberattack that took its MyChart portal offline; the Cleveland patient's suit, filed October 28, claims more than a million records were exposed, a number University Hospitals has not confirmed. University of New Mexico Health Sciences Center disclosed a cyberattack October 26 that diverted ambulances for about two hours; the BYOD extortion group claims it compromised 36,000 systems, a figure UNM has not confirmed. Philips updated its Node2Shell advisory October 27 for CVE-2026-111497, the Node.js Brotli decoder flaw it first flagged October 26 against PIC iX 4.x; the advisory still names no impacted products or fixed version. Philips updated its PHP2Shell advisory October 27 for CVE-2026-109618 and CVE-2026-109619, adding five more affected products including IntelliSpace Portal V12 and Philips Axon to the seven already listed. NorthShore Health Centers disclosed a data breach to patients October 27, one of several Midwest provider notifications issued that week. Denver Health Medical Plan notified more than 238,000 members October 26 about a vendor-related data incident.
Saturday, October 31, 2026 Issue #499  ·  Est. 2025
Independent brief for device makers

syngo Application Software

System, Image Processing, Radiological. Attributes come from Siemens Healthineers's own public documentation for this product.

Attributes

Platform
Windows
Attributes: materials
syngo
Attributes: component types
Firmware Generic Application Local Service Operating System Storage
Attributes: interface types
TCP
Attributes: assets
Firmware

Matched threat intel

25

Advisories in our coverage that share an attribute with this product. A shared attribute is a lead, not a finding. The status column shows only what Siemens Healthineers has said.

AdvisoryDateSharedSiemens Healthineers status
Siemens Healthineers fixes seven web service flaws in syngo Dynamics before VA40G HF01Nov 17, 2022Same FDA device typeNo feedback feed from manufacturer
Philips issues WannaCry guidance naming IntelliSpace Portal Workstation IX and Event ManagementMay 15, 2017Same FDA device typeNo feedback feed from manufacturer
Cepheid GeneXpert Xpress 6.4a ships without Windows speculative execution mitigationsMar 11, 2026Same property (MITRE EMB3D)PID-23No feedback feed from manufacturer
A legacy cardiology system, end-of-service since 2014, recalled for securityJun 10, 2025Same property (MITRE EMB3D)PID-23No feedback feed from manufacturer
A DICOM viewer that did not check its update server certificateFeb 20, 2025Same property (MITRE EMB3D)PID-27No feedback feed from manufacturer
MicroDicom DICOM Viewer 2024.03 fails to validate its update server certificateFeb 6, 2025Same property (MITRE EMB3D)PID-27No feedback feed from manufacturer
A patient monitor with a hidden backdoor that phones homeJan 30, 2025Same property (MITRE EMB3D)PID-27No feedback feed from manufacturer
Thermo Fisher Xcalibur and Foundation driver packages allow local privilege escalationJan 22, 2025Same property (MITRE EMB3D)PID-23No feedback feed from manufacturer
Philips Gemini PET/CT systems write sensitive data to removable media without access controlMar 25, 2021Same property (MITRE EMB3D)PID-123No feedback feed from manufacturer
B. Braun OnlineSuite AP 3.0 and earlier allows unauthenticated file upload and DLL hijackingOct 22, 2020Same property (MITRE EMB3D)PID-23No feedback feed from manufacturer
Capsule Technologies SmartLinx Neuron 2 kiosk escapes to admin with a USB keyboardJul 14, 2020Same property (MITRE EMB3D)PID-23No feedback feed from manufacturer
GE Healthcare ultrasound systems let a local user escape Kiosk Mode to the operating systemFeb 18, 2020Same property (MITRE EMB3D)PID-23No feedback feed from manufacturer
Medtronic 2090 CareLink and 29901 Encore programmers accept updates without verifying their originFeb 27, 2018Same property (MITRE EMB3D)PID-27No feedback feed from manufacturer
Canon Medical holds off on Meltdown and Spectre patches for its diagnostic imaging equipmentJan 15, 2018Same property (MITRE EMB3D)PID-23No feedback feed from manufacturer
Boston Scientific ZOOM LATITUDE PRM uses a hard-coded key and leaves patient data unencryptedOct 19, 2017Same property (MITRE EMB3D)PID-123No feedback feed from manufacturer
A crafted JPEG inside a DICOM file overflows a viewer heapAug 6, 2026Same signalsNo feedback feed from manufacturer
MicroDicom patched, then patched again, for the same file-parser classJun 10, 2025Same signalsNo feedback feed from manufacturer
Two rounds of memory-corruption bugs in one DICOM viewerMar 20, 2025Same signalsNo feedback feed from manufacturer
Santesoft Sante FFT Imaging 1.4.1 has an out-of-bounds write in DCM file handlingMar 5, 2024Same signalsNo feedback feed from manufacturer
MicroDicom DICOM Viewer 2023.3 and prior overflows the heap on malicious DCM filesFeb 29, 2024Same signalsNo feedback feed from manufacturer
Santesoft Sante DICOM Viewer Pro 14.0.3 out-of-bounds read triggered by a malicious DICOM fileFeb 27, 2024Same signalsNo feedback feed from manufacturer
Santesoft Sante DICOM Viewer Pro has two memory corruption flaws in DICOM parsingOct 12, 2023Same signalsNo feedback feed from manufacturer
Santesoft Sante FFT Imaging has an out-of-bounds read when parsing DICOM filesOct 12, 2023Same signalsNo feedback feed from manufacturer
MIM Assistant and MIM Client 7.2.10 and 7.3.3 open to XXE through DICOM RT tagsSep 19, 2023Same signalsNo feedback feed from manufacturer
Medtronic CareLink 9790, 2090 and Encore 29901 programmers store patient data unencryptedDec 13, 2018Exposed to the same EMB3D threatTID-108No feedback feed from manufacturer