NAEOTOM Alpha.Prime RT Pro Edition
Photon-counting CT scanner. Attributes come from Siemens Healthineers's own public documentation for this product.
Attributes
Signals
Properties (MITRE EMB3D)
Attributes: materials
syngo
Attributes: component types
Display Framework Generic Hardware Local Application Local Service Sensor Modules User Interface Web Application
Attributes: interface types
TCP
Attributes: assets
Patient Data Report Data Sensor Data Software Configuration
Attributes: dataflows
CT scanner to Oncology Information System (OIS) setup report CT scanner to Treatment Planning System via CT DICOM modality images Respiratory signal to CT scanner (DirectBreathhold auto-start) Treatment prescription information to CT scanner (Oncology Exchange) for automatic RT scan protocol loading
Matched threat intel
5
Advisories in our coverage that share attributes with this product, strongest first: a named product or component, the same device type or lineage, then the most shared attributes. A shared attribute is a lead, not a finding. The status column shows only what Siemens Healthineers has said.
| # | Advisory | Date | Shared | Siemens Healthineers status |
|---|---|---|---|---|
| 1 | Santesoft Sante DICOM Viewer Pro 14.0.3 out-of-bounds read triggered by a malicious DICOM file | Feb 27, 2024 | Same signals3 shared attributes: Imaging family, DICOM or image parsing, Patient Data | No response from manufacturer |
| 2 | GE Healthcare imaging and ultrasound systems expose default service credentials | Dec 8, 2020 | 7 shared attributesImaging family, Scanner, Handles patient data, Hospital network +3 | No response from manufacturer |
| 3 | Philips MRI 1.5T and 3T let operator accounts export patient data and view system files | Nov 9, 2021 | 7 shared attributesImaging family, Scanner, Handles patient data, DICOM or image parsing +3 | No response from manufacturer |
| 4 | Olympus VaultStream Server 10.x and older affected by .NET, HTTP/2 and PHP flaws | May 25, 2026 | 5 shared attributesHandles patient data, Device exposes remote network services (PID-41), Framework, TCP +1 | No response from manufacturer |
| 5 | Canon Medical says CT, MR, VL and XR systems may be exposed to RPC runtime flaw CVE-2022-26809 | Jul 4, 2022 | 3 shared attributesImaging family, Scanner, TCP | No response from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-202 Exploitable System Network Stack Component TID-210 Device Vulnerabilities Unpatchable TID-222 Critical System Service May Be Disabled TID-226 Device leaks security information in logs TID-311 Default Credentials TID-324 HTTP Direct Object Reference TID-327 Out of Bounds Memory Access TID-328 Hardcoded Credentials TID-329 Improper Password Storage TID-405 Network Stack Resource Exhaustion TID-408 Unencrypted Sensitive Data Communication
CWE weaknesses
CWE-1104 Use of Unmaintained Third Party Components CWE-122 Heap-based Buffer Overflow CWE-125 Out-of-bounds Read CWE-1329 Reliance on Component That is Not Updateable CWE-1392 Use of Default Credentials CWE-1395 Dependency on Vulnerable Third-Party Component CWE-200 Exposure of Sensitive Information to an Unauthorized Actor CWE-284 Improper Access Control CWE-522 Insufficiently Protected Credentials CWE-639 Authorization Bypass Through User-Controlled Key CWE-787 Out-of-bounds Write CWE-798 Use of Hard-coded Credentials