cobas 4000 analyzer series
Clinical chemistry and immunochemistry analyzer. Attributes come from Roche's own public documentation for this product.
Attributes
Properties (MITRE EMB3D)
Attributes: component types
Circuit Board Generic Application Generic Hardware Local Application Operating System Sensor Modules Storage User Interface
Attributes: interface types
Serial USB
Attributes: assets
Calibration Data Sensor Data Software Configuration
Attributes: dataflows
Analyzer to USB Drive (up to 2,000 results, samples and QC) Reagent Pack 2D barcode to Instrument Database (application data)
Matched threat intel
16
Advisories in our coverage that share attributes with this product, strongest first: a named product or component, the same device type or lineage, then the most shared attributes. A shared attribute is a lead, not a finding. The status column shows only what Roche has said.
| # | Advisory | Date | Shared | Roche status |
|---|---|---|---|---|
| 1 | Capsule Technologies SmartLinx Neuron 2 kiosk escapes to admin with a USB keyboard | Jul 14, 2020 | Same property (MITRE EMB3D)PID-146 shared attributes: USB port, Device includes external peripheral interconnects (e.g., USB, Serial) (PID-14), Device includes OS/kernel (PID-23), Operating System +2 | No response from manufacturer |
| 2 | Baxter ExactaMix compounders carry hard-coded admin credentials and send orders in clear text | Jun 18, 2020 | 9 shared attributesUser accounts, USB port, Patient or study database, Device includes external peripheral interconnects (e.g., USB, Serial) (PID-14) +5 | No response from manufacturer |
| 3 | BD FACSLyric workstations on Windows 10 expose an administrative account | Jan 29, 2019 | 7 shared attributesLab and diagnostics family, Analyzer, Named operating system, Device includes OS/kernel (PID-23) +3 | No response from manufacturer |
| 4 | BD FACSChorus workstations leave USB, BIOS and PCIe open and store admin secrets in plaintext | Nov 27, 2023 | 6 shared attributesLab and diagnostics family, Named operating system, USB port, Patient or study database +2 | No response from manufacturer |
| 5 | Beckman Coulter maps PrintNightmare print spooler flaws across its lab instrument line | Aug 13, 2021 | 5 shared attributesLab and diagnostics family, Analyzer, Clinical, Named operating system +1 | No response from manufacturer |
| 6 | Cepheid GeneXpert Xpress 6.4a ships without Windows speculative execution mitigations | Mar 11, 2026 | 5 shared attributesLab and diagnostics family, Named operating system, Device includes OS/kernel (PID-23), Operating System +1 | No response from manufacturer |
| 7 | Beckman Coulter issues per-instrument guidance as Petya ransomware spreads through EternalBlue | Jun 28, 2017 | 6 shared attributesLab and diagnostics family, Analyzer, Clinical, Local Application +2 | No response from manufacturer |
| 8 | GE Aestiva and Aespire anesthesia devices can have alarms silenced through unsecured terminal servers | Jul 9, 2019 | 5 shared attributesSerial interface, Device includes external peripheral interconnects (e.g., USB, Serial) (PID-14), Generic Hardware, Serial +1 | No response from manufacturer |
| 9 | Cepheid GeneXpert Dx 6.4a needs Windows 10 update KB5068781 for 32 CVEs | Mar 12, 2026 | 5 shared attributesLab and diagnostics family, Named operating system, Device includes OS/kernel (PID-23), Operating System +1 | No response from manufacturer |
| 10 | Cepheid GeneXpert touchscreens on Cepheid OS 2.1 need three Windows 10 kernel updates | Sep 30, 2025 | 4 shared attributesLab and diagnostics family, Named operating system, Device includes OS/kernel (PID-23), Operating System | No response from manufacturer |
| 11 | Beckman Coulter publishes WannaCry guidance for lab instruments missing MS17-010 | May 19, 2017 | 4 shared attributesLab and diagnostics family, Analyzer, Clinical, Operating System | No response from manufacturer |
| 12 | Philips lists Holter SW, ST80i and Focal Point under Windows CLFS zero-day CVE-2022-37969 | Oct 20, 2022 | 4 shared attributesClinical, Named operating system, Device includes OS/kernel (PID-23), Operating System | No response from manufacturer |
| 13 | BD lists FACS, Pyxis and Kiestra products in scope for Win32k zero-day CVE-2021-1732 | Jul 29, 2021 | 4 shared attributesLab and diagnostics family, Named operating system, Operating System, Local Application | No response from manufacturer |
| 14 | BD tests Windows DNS Server patch for CVE-2020-1350 on Alaris, HealthSight and Kiestra | Sep 8, 2020 | 3 shared attributesLab and diagnostics family, Clinical, Named operating system | No response from manufacturer |
| 15 | Thermo Fisher ePort software up to 3.0.0 carries improper access control flaw CVE-2025-32992 | Aug 18, 2025 | 3 shared attributesLab and diagnostics family, User accounts, Local Application | No response from manufacturer |
| 16 | Philips lists Flex Cardio, XperIM and SensaVue under Follina MSDT flaw CVE-2022-30190 | Jun 30, 2022 | 3 shared attributesClinical, Named operating system, Local Application | No response from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-103 Microarchitectural Side Channels TID-107 Unauthorized Direct Memory Access (DMA) TID-111 Untrusted External Storage TID-202 Exploitable System Network Stack Component TID-204 Untrusted Programs Can Access Privileged OS Functions TID-205 Existing OS Tools Maliciously Used for Device Manipulation TID-210 Device Vulnerabilities Unpatchable TID-219 OS/Kernel Privilege Escalation TID-222 Critical System Service May Be Disabled TID-226 Device leaks security information in logs TID-310 Remotely Accessible Unauthenticated Services TID-311 Default Credentials TID-314 Passwords Can Be Guessed Using Brute-Force Attempts TID-324 HTTP Direct Object Reference TID-328 Hardcoded Credentials TID-329 Improper Password Storage TID-406 Unauthorized Messages or Connections TID-408 Unencrypted Sensitive Data Communication
CWE weaknesses
CWE-1104 Use of Unmaintained Third Party Components CWE-1188 Insecure Default Initialization of Resource CWE-1329 Reliance on Component That is Not Updateable CWE-1392 Use of Default Credentials CWE-200 Exposure of Sensitive Information to an Unauthorized Actor CWE-276 Incorrect Default Permissions CWE-284 Improper Access Control CWE-427 Uncontrolled Search Path Element CWE-522 Insufficiently Protected Credentials CWE-639 Authorization Bypass Through User-Controlled Key CWE-798 Use of Hard-coded Credentials