TipTraQ Home Sleep Apnea Test
Home sleep apnea test system. Attributes come from Pranaq's own public documentation for this product.
Attributes
Signals
Properties (MITRE EMB3D)
PID-31 Application-level software is present and running on the device PID-311 Device includes the usage of a web/HTTP applications PID-33 Device includes interactive applications, services, or user interfaces PID-332 Device includes authenticated services PID-41 Device exposes remote network services PID-411 Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations
Platform
Android
Attributes: component types
API Battery Cloud Service Generic Application Local Application Local Service Mobile Application User Interface Web Application
Attributes: interface types
Bluetooth TCP
Attributes: assets
Patient Data Report Data Sensor Data User Data
Attributes: dataflows
Cloud to Expert Panel (sleep reports for clinicians) Companion App/Sensor to Cloud for auto-scoring Expert Panel to Companion App (validated report to patient) Expert Panel to Sensor (remote activation of additional sleep tests) Sensor to Companion App over Bluetooth
Matched threat intel
Top 20 of 22
Advisories in our coverage that share attributes with this product, strongest first: a named product or component, the same device type or lineage, then the most shared attributes. A shared attribute is a lead, not a finding. The status column shows only what Pranaq has said.
| # | Advisory | Date | Shared | Pranaq status |
|---|---|---|---|---|
| 1 | Dario Health glucose monitoring app and servers exposed cross-user health data | Feb 27, 2025 | Same property (MITRE EMB3D)PID-31112 shared attributes: Cloud connectivity, Mobile app, Handles patient data, Web interface +8 | No response from manufacturer |
| 2 | User enumeration on the CareLink Network, found at a conference | Dec 4, 2025 | Same property (MITRE EMB3D)PID-3119 shared attributes: Cloud connectivity, Web interface, Remote access, Handles patient data +5 | No response from manufacturer |
| 3 | Medtronic MyCareLink Smart 25000 reader allows Bluetooth authentication bypass and unsigned firmware | Dec 10, 2020 | Same platformAndroid 6.010 shared attributes: Wireless connectivity, Mobile app, Cloud connectivity, Home use +6 | No response from manufacturer |
| 4 | Missing authentication on a DNA sequencer control plane | Oct 21, 2025 | Same property (MITRE EMB3D)PID-41112 shared attributes: Handles patient data, Remote access, Wireless connectivity, Cloud connectivity +8 | No response from manufacturer |
| 5 | Missing authentication lets an attacker rewrite a cardiac wearable | May 28, 2026 | Same property (MITRE EMB3D)PID-41111 shared attributes: Wireless connectivity, Handles patient data, Mobile app, Remote access +7 | No response from manufacturer |
| 6 | LifePoint Informatics Patient Portal generated lab report PDFs from a URL and a patient ID | Apr 5, 2022 | Same property (MITRE EMB3D)PID-3117 shared attributes: Web interface, Handles patient data, Cloud connectivity, Device includes the usage of a web/HTTP applications (PID-311) +3 | No response from manufacturer |
| 7 | A hard-coded VNC password on a bioreactor, base score 9.8 | May 26, 2026 | Same property (MITRE EMB3D)PID-4119 shared attributes: Remote access, Wireless connectivity, Device includes authenticated services (PID-332), Device exposes remote network services (PID-41) +5 | No response from manufacturer |
| 8 | Philips EncoreAnywhere exposes sensitive data in its HTTP headers | May 17, 2018 | Same property (MITRE EMB3D)PID-3115 shared attributes: Cloud connectivity, Web interface, Device includes the usage of a web/HTTP applications (PID-311), Web Application +1 | No response from manufacturer |
| 9 | Apollo Pharmacy APG-01 BT glucose meter sends readings over BLE in cleartext | Jun 18, 2026 | Same property (MITRE EMB3D)PID-4116 shared attributes: Wireless connectivity, Handles patient data, Home use, Mobile app +2 | No response from manufacturer |
| 10 | Change Healthcare PeerVue Web Server leaks technical details in HTTP error messages | Oct 4, 2018 | Same property (MITRE EMB3D)PID-3114 shared attributes: Web interface, Device includes the usage of a web/HTTP applications (PID-311), Web Application, TCP | No response from manufacturer |
| 11 | B. Braun SpaceStation with SpaceCom module has an open redirect in its web server | Mar 23, 2017 | Same property (MITRE EMB3D)PID-3114 shared attributes: Web interface, Device includes the usage of a web/HTTP applications (PID-311), Web Application, TCP | No response from manufacturer |
| 12 | BPL PWS-01-BT weighing scale sends unencrypted, unauthenticated BLE data to the Be Well app | Sep 10, 2024 | Same platformAndroid5 shared attributes: Wireless connectivity, Mobile app, Home use, Mobile Application +1 | No response from manufacturer |
| 13 | BD Pyxis dispensing and supply systems ship with hard-coded credentials across 24 products | Mar 3, 2022 | Exposed to the same EMB3D threatTID-3113 shared attributes: Handles patient data, Generic Application, Patient Data | No response from manufacturer |
| 14 | Cl0p lists Philips among nearly 50 victims of its PTC Windchill campaign | Aug 14, 2026 | 12 shared attributesCloud connectivity, Remote access, Web interface, Handles patient data +8 | No response from manufacturer |
| 15 | EMS patient-care app reflects unsanitized input into a WebView | Feb 10, 2026 | 10 shared attributesHandles patient data, Mobile app, Cloud connectivity, Remote access +6 | No response from manufacturer |
| 16 | Fresenius lists Conox anesthesia monitor as affected by BLUFFS Bluetooth flaw | Apr 10, 2024 | 7 shared attributesRespiratory and anesthesia family, Wireless connectivity, Physiological waveform processing, Handles patient data +3 | No response from manufacturer |
| 17 | Philips DreamMapper exposes log file information in versions 2.24.x and prior | Jul 30, 2020 | 5 shared attributesRespiratory and anesthesia family, Sleep, Mobile app, Home use +1 | No response from manufacturer |
| 18 | Natus Xltek NeuroWorks 8 has eight packet parsing flaws, three scored 10.0 | Jun 14, 2018 | 6 shared attributesRespiratory and anesthesia family, Sleep, Physiological waveform processing, Device exposes remote network services (PID-41) +2 | No response from manufacturer |
| 19 | Philips Alice 6 sleep system has hard-coded credentials and cleartext patient data | Mar 26, 2018 | 6 shared attributesRespiratory and anesthesia family, Sleep, Handles patient data, Physiological waveform processing +2 | No response from manufacturer |
| 20 | ShinyHunters and Redact both claim DexCom breaches, nine days apart | Oct 10, 2026 | 5 shared attributesDevice includes interactive applications, services, or user interfaces (PID-33), Mobile Application, Sensor Data, Patient Data +1 | No response from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-213 Faulty FW/SW Update Integrity Verification TID-222 Critical System Service May Be Disabled TID-224 Excessive Access via Software Diagnostic Features TID-226 Device leaks security information in logs TID-304 Manipulate Runtime Environment TID-310 Remotely Accessible Unauthenticated Services TID-311 Default Credentials TID-313 Unauthenticated Session Changes Credential TID-316 Incorrect Certificate Verification Allows Authentication Bypass TID-319 Cross Site Scripting (XSS) TID-324 HTTP Direct Object Reference TID-326 Insecure Deserialization TID-327 Out of Bounds Memory Access TID-328 Hardcoded Credentials TID-329 Improper Password Storage TID-401 Undocumented Protocol Features TID-404 Remotely Triggerable Deadlock/DoS TID-405 Network Stack Resource Exhaustion TID-406 Unauthorized Messages or Connections TID-407 Missing Message Replay Protection TID-408 Unencrypted Sensitive Data Communication TID-411 Weak/Insecure Cryptographic Protocol
CWE weaknesses
CWE-1188 Insecure Default Initialization of Resource CWE-122 Heap-based Buffer Overflow CWE-125 Out-of-bounds Read CWE-1390 Weak Authentication CWE-1392 Use of Default Credentials CWE-20 Improper Input Validation CWE-200 Exposure of Sensitive Information to an Unauthorized Actor CWE-276 Incorrect Default Permissions CWE-284 Improper Access Control CWE-287 Improper Authentication CWE-290 Authentication Bypass by Spoofing CWE-294 Authentication Bypass by Capture-replay CWE-306 Missing Authentication for Critical Function CWE-319 Cleartext Transmission of Sensitive Information CWE-326 Inadequate Encryption Strength CWE-400 Uncontrolled Resource Consumption CWE-476 NULL Pointer Dereference CWE-502 Deserialization of Untrusted Data CWE-522 Insufficiently Protected Credentials CWE-639 Authorization Bypass Through User-Controlled Key CWE-787 Out-of-bounds Write CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') CWE-798 Use of Hard-coded Credentials