HeartStart Configure
AED configuration software. Attributes come from Philips's own public documentation for this product.
Attributes
Signals
Properties (MITRE EMB3D)
PID-123 Device includes ROM, VRAM, or removable Storage PID-27 Device includes support for firmware/software updates PID-275 Device includes remotely-initiated firmware/software updates PID-31 Application-level software is present and running on the device PID-311 Device includes the usage of a web/HTTP applications PID-33 Device includes interactive applications, services, or user interfaces PID-41 Device exposes remote network services PID-411 Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations
Platform
Windows Windows 10
Attributes: materials
Windows 10 Windows Vista Windows XP
Attributes: component types
API CPU Display Firmware Generic Application Local Application Local Service Operating System Platform Storage User Interface Web Application Wireless Module
Attributes: interface types
Bluetooth SDIO TCP
Attributes: assets
Software Configuration Software Update
Attributes: dataflows
Computer to AED (retrieve, reset, revise configuration) Computer to Configuration File (save settings) Computer to FR3 defibrillator over Bluetooth (configuration, clock) Computer to FR3 defibrillator via SD data card (configuration, language) FR3 defibrillator to Computer over Bluetooth (configuration retrieval) Internet to Computer (software updates)
Matched threat intel
Top 20 of 23
Advisories in our coverage that share attributes with this product, strongest first: a named product or component, the same device type or lineage, then the most shared attributes. A shared attribute is a lead, not a finding. The status column shows only what Philips has said.
| # | Advisory | Date | Shared | Philips status |
|---|---|---|---|---|
| 1 | BD maps its product line against the vulnerabilities Ryuk ransomware exploits | Oct 30, 2020 | Same named componentWindows Vista (= SP2) | No response from manufacturer |
| 2 | A DICOM viewer that did not check its update server certificate | Feb 20, 2025 | Same property (MITRE EMB3D)PID-27510 shared attributes: Field-updatable firmware, Cloud connectivity, Wireless connectivity, Device includes support for firmware/software updates (PID-27) +6 | No response from manufacturer |
| 3 | Medtronic 2090 CareLink and 29901 Encore programmers accept updates without verifying their origin | Feb 27, 2018 | Same property (MITRE EMB3D)PID-2756 shared attributes: Field-updatable firmware, Cloud connectivity, Device includes support for firmware/software updates (PID-27), Generic Application +2 | No response from manufacturer |
| 4 | MicroDicom DICOM Viewer 2024.03 fails to validate its update server certificate | Feb 6, 2025 | Same property (MITRE EMB3D)PID-2754 shared attributes: Field-updatable firmware, Device includes support for firmware/software updates (PID-27), Local Application, Software Update | No response from manufacturer |
| 5 | B. Braun OnlineSuite AP 3.0 and earlier allows unauthenticated file upload and DLL hijacking | Oct 22, 2020 | Exposed to the same EMB3D threatTID-3234 shared attributes: File import, Named operating system, Generic Application, TCP | No response from manufacturer |
| 6 | Canon Medical flags FragAttacks Wi-Fi flaws in wireless FPD and ultrasound wireless options | Jul 4, 2022 | Same platformWindows 10 IoT Enterprise2 shared attributes: Wireless connectivity, Wireless Module | No response from manufacturer |
| 7 | Thermo Fisher Xcalibur and Foundation driver packages allow local privilege escalation | Jan 22, 2025 | Same platformWindows2 shared attributes: Named operating system, Local Application | No response from manufacturer |
| 8 | B. Braun SpaceCom and Battery Pack SP with Wi-Fi carry 11 flaws from XSS to unsigned firmware | Oct 22, 2020 | 12 shared attributesWireless connectivity, Field-updatable firmware, Named operating system, Device includes the usage of a web/HTTP applications (PID-311) +8 | No response from manufacturer |
| 9 | Flow Neuroscience FL-100 ships a shared Bluetooth credential in every unit | Aug 13, 2026 | 11 shared attributesWireless connectivity, Field-updatable firmware, Device exposes remote network services (PID-41), Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations (PID-411) +7 | No response from manufacturer |
| 10 | Silex modules in GE MobileLink allow unauthenticated setting changes and command injection | May 8, 2018 | 8 shared attributesDevice includes the usage of a web/HTTP applications (PID-311), Device includes support for firmware/software updates (PID-27), Wireless Module, Operating System +4 | No response from manufacturer |
| 11 | BD Alaris Gateway Workstation accepts malicious files during firmware update | Jun 13, 2019 | 7 shared attributesField-updatable firmware, Device includes the usage of a web/HTTP applications (PID-311), Firmware, Web Application +3 | No response from manufacturer |
| 12 | BD Alaris 8015 PC unit exposes stored Wi-Fi credentials on its removable flash card | Jan 17, 2017 | 6 shared attributesRemovable media, Wireless connectivity, Device includes ROM, VRAM, or removable Storage (PID-123), Wireless Module +2 | No response from manufacturer |
| 13 | Baxter warns of a Newmar radio PIM file flaw in Connex vital signs monitors | Feb 18, 2026 | 6 shared attributesWireless connectivity, Field-updatable firmware, Device includes support for firmware/software updates (PID-27), Wireless Module +2 | No response from manufacturer |
| 14 | Medtronic MyCareLink monitors expose a debug port with a hard-coded OS password | Jun 28, 2018 | 6 shared attributesWireless connectivity, Field-updatable firmware, Device includes remotely-initiated firmware/software updates (PID-275), Operating System +2 | No response from manufacturer |
| 15 | bioMérieux says three Access:7 flaws reach VILINK with Axeda, rated low risk behind the firewall | Mar 8, 2022 | 6 shared attributesRemote access, Named operating system, Device includes remotely-initiated firmware/software updates (PID-275), Local Service +2 | No response from manufacturer |
| 16 | Illumina Universal Copy Service on sequencers binds to every IP address and runs with excess privileges | Apr 27, 2023 | 7 shared attributesFile import, Device exposes remote network services (PID-41), Local Service, Operating System +3 | No response from manufacturer |
| 17 | Philips lists ST80i and PIC iX under Windows CLFS flaws CVE-2025-32706 and CVE-2025-30397 | May 20, 2025 | 4 shared attributesNamed operating system, Operating System, TCP, Software Update | No response from manufacturer |
| 18 | CARTO 3 Versions 6 and 7.1 run vulnerable Print Spooler, fixed in Security Service Pack 4 | Nov 23, 2022 | 4 shared attributesNamed operating system, Operating System, Local Service, Software Update | No response from manufacturer |
| 19 | BD rates Meltdown and Spectre low impact across its instrument and Pyxis lines | Jan 5, 2018 | 3 shared attributesCPU, Firmware, Software Update | No response from manufacturer |
| 20 | Biosense Webster CARTO 3 V6 SP3 applies Windows patches and antivirus updates | Jan 8, 2021 | 4 shared attributesNamed operating system, Operating System, Local Application, Software Update | No response from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-103 Microarchitectural Side Channels TID-108 ROM/NVRAM Data Extraction or Modification TID-111 Untrusted External Storage TID-115 Firmware/Data Extraction via Hardware Interface TID-116 Latent Privileged Access Port TID-119 Latent Hardware Debug Port Allows Memory/Code Manipulation TID-202 Exploitable System Network Stack Component TID-204 Untrusted Programs Can Access Privileged OS Functions TID-205 Existing OS Tools Maliciously Used for Device Manipulation TID-210 Device Vulnerabilities Unpatchable TID-211 Device Allows Unauthenticated Firmware Installation TID-213 Faulty FW/SW Update Integrity Verification TID-215 Unencrypted SW/FW Updates TID-219 OS/Kernel Privilege Escalation TID-221 Authentication Bypass By Message Replay TID-222 Critical System Service May Be Disabled TID-224 Excessive Access via Software Diagnostic Features TID-302 Install Untrusted Application TID-305 Program Executes Dangerous System Calls TID-310 Remotely Accessible Unauthenticated Services TID-311 Default Credentials TID-316 Incorrect Certificate Verification Allows Authentication Bypass TID-317 Predictable Cryptographic Key TID-319 Cross Site Scripting (XSS) TID-321 HTTP Application Session Hijacking TID-323 Path Traversal TID-328 Hardcoded Credentials TID-329 Improper Password Storage TID-404 Remotely Triggerable Deadlock/DoS TID-406 Unauthorized Messages or Connections TID-408 Unencrypted Sensitive Data Communication
CWE weaknesses
CWE-1104 Use of Unmaintained Third Party Components CWE-1188 Insecure Default Initialization of Resource CWE-1191 On-Chip Debug and Test Interface With Improper Access Control CWE-1313 Hardware Allows Activation of Test or Debug Logic at Runtime CWE-1329 Reliance on Component That is Not Updateable CWE-1392 Use of Default Credentials CWE-1395 Dependency on Vulnerable Third-Party Component CWE-22 Improper Limitation of a Pathname to a Restricted Directory CWE-276 Incorrect Default Permissions CWE-294 Authentication Bypass by Capture-replay CWE-321 Use of Hard-coded Cryptographic Key CWE-345 Insufficient Verification of Data Authenticity CWE-427 Uncontrolled Search Path Element CWE-434 Unrestricted Upload of File with Dangerous Type CWE-494 Download of Code Without Integrity Check CWE-522 Insufficiently Protected Credentials CWE-798 Use of Hard-coded Credentials CWE-916 Use of Password Hash With Insufficient Computational Effort