Optomed Radiology Information System
Radiology information system software. Attributes come from Optomed's own public documentation for this product.
Attributes
Signals
Properties (MITRE EMB3D)
Attributes: component types
Generic Application Local Service Operating System
Attributes: interface types
Unknown
Attributes: assets
Patient Data Report Data User Data
Attributes: dataflows
Optomed RIS to Imaging Equipment, Image Archives, Patient Information Systems and Hospital Information Systems via stand Optomed RIS to Reporting Systems (statistical data)
Matched threat intel
6
Advisories in our coverage that share attributes with this product, strongest first: a named product or component, the same device type or lineage, then the most shared attributes. A shared attribute is a lead, not a finding. The status column shows only what Optomed has said.
| # | Advisory | Date | Shared | Optomed status |
|---|---|---|---|---|
| 1 | Philips IntelliSpace Cardiovascular and Xcelera servers allow privilege escalation through writable executable folders | Aug 14, 2018 | Same property (MITRE EMB3D)PID-23223 shared attributes: Information, User accounts, Role-based access | No response from manufacturer |
| 2 | BD Synapsys sessions did not expire, risking changes to patient data | May 31, 2022 | Same property (MITRE EMB3D)PID-3324 shared attributes: User accounts, Handles patient data, Device includes authenticated services (PID-332), Patient Data | No response from manufacturer |
| 3 | Philips names ten product lines in Windows Task Scheduler CVE-2024-49039 notice | Nov 18, 2024 | 6 shared attributesImaging family, Information, Radiology, Hospital network +2 | No response from manufacturer |
| 4 | Philips lists Vue PACS and Vue RIS under Mirth Connect flaws CVE-2023-37679 and CVE-2023-43208 | Nov 3, 2023 | 4 shared attributesImaging family, Radiology, Information, HL7 or FHIR integration | No response from manufacturer |
| 5 | Philips ultrasound systems expose an alternate service login that skips authentication | Jun 25, 2020 | 4 shared attributesImaging family, User accounts, Device includes authenticated services (PID-332), Generic Application | No response from manufacturer |
| 6 | Philips MRI 1.5T and 3T software has access control and ownership flaws in versions 5.3 to 5.8.1 | Nov 9, 2021 | 3 shared attributesImaging family, User accounts, Handles patient data | No response from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-116 Latent Privileged Access Port TID-202 Exploitable System Network Stack Component TID-204 Untrusted Programs Can Access Privileged OS Functions TID-205 Existing OS Tools Maliciously Used for Device Manipulation TID-210 Device Vulnerabilities Unpatchable TID-219 OS/Kernel Privilege Escalation TID-224 Excessive Access via Software Diagnostic Features TID-226 Device leaks security information in logs TID-310 Remotely Accessible Unauthenticated Services TID-324 HTTP Direct Object Reference TID-401 Undocumented Protocol Features
CWE weaknesses
CWE-1104 Use of Unmaintained Third Party Components CWE-1395 Dependency on Vulnerable Third-Party Component CWE-200 Exposure of Sensitive Information to an Unauthorized Actor CWE-284 Improper Access Control CWE-427 Uncontrolled Search Path Element CWE-506 Embedded Malicious Code CWE-522 Insufficiently Protected Credentials CWE-639 Authorization Bypass Through User-Controlled Key CWE-912 Hidden Functionality