Optomed Lumo
Handheld fundus camera. Attributes come from Optomed's own public documentation for this product.
Attributes
Signals
Properties (MITRE EMB3D)
PID-14 Device includes external peripheral interconnects (e.g., USB, Serial) PID-27 Device includes support for firmware/software updates PID-275 Device includes remotely-initiated firmware/software updates PID-33 Device includes interactive applications, services, or user interfaces PID-332 Device includes authenticated services PID-3321 Device includes passwords to authenticate the users PID-4113 Device includes cryptographic functions for sensitive data, such as encryption or authentication
Attributes: component types
Circuit Board Cloud Service Display Firmware Library Local Application Local Service Mobile Application Sensor Modules User Interface
Attributes: interface types
USB WiFi
Attributes: assets
Credentials Software Update User Data
Attributes: dataflows
Camera to Cloud (optional) Camera to PACS via wireless DICOM Camera to host over USB (image transfer) Camera to host over WLAN (image transfer) Cloud to Camera (remote software updates)
Matched threat intel
Top 20 of 57
Advisories in our coverage that share attributes with this product, strongest first: a named product or component, the same device type or lineage, then the most shared attributes. A shared attribute is a lead, not a finding. The status column shows only what Optomed has said.
| # | Advisory | Date | Shared | Optomed status |
|---|---|---|---|---|
| 1 | Medtronic 2090 CareLink and 29901 Encore programmers accept updates without verifying their origin | Feb 27, 2018 | Same property (MITRE EMB3D)PID-33219 shared attributes: Field-updatable firmware, Cloud connectivity, USB port, Device includes support for firmware/software updates (PID-27) +5 | No response from manufacturer |
| 2 | A DICOM viewer that did not check its update server certificate | Feb 20, 2025 | Same property (MITRE EMB3D)PID-27511 shared attributes: Field-updatable firmware, Cloud connectivity, User accounts, Hospital network +7 | No response from manufacturer |
| 3 | Roche Accu-Chek and CoaguChek point of care handhelds expose a weakly protected service interface | Nov 6, 2018 | Same property (MITRE EMB3D)PID-33219 shared attributes: Handheld, Wireless connectivity, Field-updatable firmware, Hospital network +5 | No response from manufacturer |
| 4 | Swisslog Translogic Nexus Control Panel ships hard-coded root passwords and unvalidated updates | Aug 3, 2021 | Same property (MITRE EMB3D)PID-33218 shared attributes: User accounts, Field-updatable firmware, Hospital network, Device includes passwords to authenticate the users (PID-3321) +4 | No response from manufacturer |
| 5 | Stored passwords recoverable in a Siemens imaging platform | Feb 10, 2026 | Same property (MITRE EMB3D)PID-33217 shared attributes: User accounts, Hospital network, Device includes passwords to authenticate the users (PID-3321), Device includes cryptographic functions for sensitive data, such as encryption or authentication (PID-4113) +3 | No response from manufacturer |
| 6 | Hillrom Welch Allyn ELI resting electrocardiographs contain hard-coded passwords | Jun 16, 2022 | Same property (MITRE EMB3D)PID-33216 shared attributes: User accounts, Hospital network, Device includes passwords to authenticate the users (PID-3321), Firmware +2 | No response from manufacturer |
| 7 | Philips PageWriter TC cardiographs expose a hard-coded superuser password and unchecked input | Aug 16, 2018 | Same property (MITRE EMB3D)PID-33215 shared attributes: User accounts, Hospital network, Device includes passwords to authenticate the users (PID-3321), User Interface +1 | No response from manufacturer |
| 8 | BD Pyxis products may still run on shared default operating system credentials | May 31, 2022 | Same property (MITRE EMB3D)PID-33214 shared attributes: User accounts, Hospital network, Device includes passwords to authenticate the users (PID-3321), Credentials | No response from manufacturer |
| 9 | Philips iSite and IntelliSpace PACS carry default credentials in third-party software | Nov 8, 2018 | Same property (MITRE EMB3D)PID-33214 shared attributes: User accounts, Hospital network, Device includes passwords to authenticate the users (PID-3321), Credentials | No response from manufacturer |
| 10 | Philips IntelliSpace Cardiovascular and Xcelera store credentials in cleartext | Nov 14, 2017 | Same property (MITRE EMB3D)PID-33215 shared attributes: User accounts, Hospital network, Local Service, Credentials +1 | No response from manufacturer |
| 11 | Medtronic MyCareLink 24950 and 24952 monitors store upload credentials in a recoverable format | Aug 7, 2018 | Same property (MITRE EMB3D)PID-33214 shared attributes: Cloud connectivity, Device includes cryptographic functions for sensitive data, such as encryption or authentication (PID-4113), Cloud Service, Credentials | No response from manufacturer |
| 12 | Baxter Welch Allyn Connex Spot Monitor used a default cryptographic key | May 30, 2024 | Same property (MITRE EMB3D)PID-275 shared attributes: Field-updatable firmware, Hospital network, Wireless connectivity, Device includes cryptographic functions for sensitive data, such as encryption or authentication (PID-4113) +1 | No response from manufacturer |
| 13 | MicroDicom DICOM Viewer 2024.03 fails to validate its update server certificate | Feb 6, 2025 | Same property (MITRE EMB3D)PID-2755 shared attributes: Field-updatable firmware, Device includes support for firmware/software updates (PID-27), Local Application, Cloud Service +1 | No response from manufacturer |
| 14 | Ossur Logic mobile app shipped hard-coded credentials and a static token in its binary | Dec 19, 2024 | Same property (MITRE EMB3D)PID-33214 shared attributes: Mobile app, User accounts, Mobile Application, Credentials | No response from manufacturer |
| 15 | BD Alaris 8000 PC unit stores wireless network credentials unencrypted in flash memory | Jan 17, 2017 | Exposed to the same EMB3D threatTID-3293 shared attributes: Wireless connectivity, Hospital network, Credentials | No response from manufacturer |
| 16 | Mira’s cloud login accepted any password and returned a session token | Aug 11, 2026 | 12 shared attributesCloud connectivity, User accounts, Mobile app, Wireless connectivity +8 | No response from manufacturer |
| 17 | Flow Neuroscience FL-100 ships a shared Bluetooth credential in every unit | Aug 13, 2026 | 11 shared attributesWireless connectivity, User accounts, Field-updatable firmware, Device includes authenticated services (PID-332) +7 | No response from manufacturer |
| 18 | B. Braun SpaceCom and Battery Pack SP with Wi-Fi carry 11 flaws from XSS to unsigned firmware | Oct 22, 2020 | 9 shared attributesWireless connectivity, Field-updatable firmware, User accounts, Device includes support for firmware/software updates (PID-27) +5 | No response from manufacturer |
| 19 | Contec CMS8000 patient monitors crash on a UDP broadcast and accept unauthenticated USB firmware | Sep 1, 2022 | 10 shared attributesUSB port, Wireless connectivity, Field-updatable firmware, Device includes external peripheral interconnects (e.g., USB, Serial) (PID-14) +6 | No response from manufacturer |
| 20 | A hard-coded VNC password on a bioreactor, base score 9.8 | May 26, 2026 | 11 shared attributesUser accounts, Wireless connectivity, Field-updatable firmware, Hospital network +7 | No response from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-107 Unauthorized Direct Memory Access (DMA) TID-108 ROM/NVRAM Data Extraction or Modification TID-111 Untrusted External Storage TID-115 Firmware/Data Extraction via Hardware Interface TID-116 Latent Privileged Access Port TID-119 Latent Hardware Debug Port Allows Memory/Code Manipulation TID-202 Exploitable System Network Stack Component TID-204 Untrusted Programs Can Access Privileged OS Functions TID-205 Existing OS Tools Maliciously Used for Device Manipulation TID-210 Device Vulnerabilities Unpatchable TID-211 Device Allows Unauthenticated Firmware Installation TID-213 Faulty FW/SW Update Integrity Verification TID-215 Unencrypted SW/FW Updates TID-219 OS/Kernel Privilege Escalation TID-221 Authentication Bypass By Message Replay TID-222 Critical System Service May Be Disabled TID-224 Excessive Access via Software Diagnostic Features TID-225 Logs can be manipulated on the device TID-226 Device leaks security information in logs TID-305 Program Executes Dangerous System Calls TID-310 Remotely Accessible Unauthenticated Services TID-311 Default Credentials TID-312 Credential Change Mechanism Can Be Abused TID-313 Unauthenticated Session Changes Credential TID-314 Passwords Can Be Guessed Using Brute-Force Attempts TID-315 Password Retrieval Mechanism Abused TID-316 Incorrect Certificate Verification Allows Authentication Bypass TID-317 Predictable Cryptographic Key TID-318 Insecure Cryptographic Implementation TID-319 Cross Site Scripting (XSS) TID-320 SQL Injection TID-321 HTTP Application Session Hijacking TID-323 Path Traversal TID-324 HTTP Direct Object Reference TID-326 Insecure Deserialization TID-327 Out of Bounds Memory Access TID-328 Hardcoded Credentials TID-329 Improper Password Storage TID-401 Undocumented Protocol Features TID-404 Remotely Triggerable Deadlock/DoS TID-405 Network Stack Resource Exhaustion TID-406 Unauthorized Messages or Connections TID-407 Missing Message Replay Protection TID-408 Unencrypted Sensitive Data Communication TID-411 Weak/Insecure Cryptographic Protocol
CWE weaknesses
CWE-1104 Use of Unmaintained Third Party Components CWE-1188 Insecure Default Initialization of Resource CWE-1191 On-Chip Debug and Test Interface With Improper Access Control CWE-1313 Hardware Allows Activation of Test or Debug Logic at Runtime CWE-1329 Reliance on Component That is Not Updateable CWE-1390 Weak Authentication CWE-1392 Use of Default Credentials CWE-1395 Dependency on Vulnerable Third-Party Component CWE-20 Improper Input Validation CWE-200 Exposure of Sensitive Information to an Unauthorized Actor CWE-22 Improper Limitation of a Pathname to a Restricted Directory CWE-276 Incorrect Default Permissions CWE-284 Improper Access Control CWE-287 Improper Authentication CWE-290 Authentication Bypass by Spoofing CWE-294 Authentication Bypass by Capture-replay CWE-306 Missing Authentication for Critical Function CWE-319 Cleartext Transmission of Sensitive Information CWE-321 Use of Hard-coded Cryptographic Key CWE-326 Inadequate Encryption Strength CWE-345 Insufficient Verification of Data Authenticity CWE-400 Uncontrolled Resource Consumption CWE-427 Uncontrolled Search Path Element CWE-434 Unrestricted Upload of File with Dangerous Type CWE-476 NULL Pointer Dereference CWE-494 Download of Code Without Integrity Check CWE-502 Deserialization of Untrusted Data CWE-506 Embedded Malicious Code CWE-522 Insufficiently Protected Credentials CWE-639 Authorization Bypass Through User-Controlled Key CWE-798 Use of Hard-coded Credentials CWE-912 Hidden Functionality CWE-916 Use of Password Hash With Insufficient Computational Effort