CytoInsight GSL
Cytogenomics image analysis system. Attributes come from Leica Biosystems's own public documentation for this product.
Attributes
Properties (MITRE EMB3D)
PID-23 Device includes OS/kernel PID-2322 Device deploys an access enforcement/privilege mechanism PID-31 Application-level software is present and running on the device PID-332 Device includes authenticated services PID-34 Device stores logs of application events and information PID-41 Device exposes remote network services PID-411 Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations
Platform
Windows Windows 11
Attributes: materials
Windows 11
Attributes: component types
API Display Generic Application Generic Hardware Local Application Local Service Operating System Sensor Modules
Attributes: interface types
TCP
Attributes: assets
Log Data Report Data Sensor Data User Data
Attributes: dataflows
CytoInsight GSL system to off-site reviewer via integrated remote access (brightfield and fluorescence analysis)
Matched threat intel
Top 20 of 39
Advisories in our coverage that share attributes with this product, strongest first: a named product or component, the same device type or lineage, then the most shared attributes. A shared attribute is a lead, not a finding. The status column shows only what Leica Biosystems has said.
| # | Advisory | Date | Shared | Leica Biosystems status |
|---|---|---|---|---|
| 1 | Philips lists Corsium and IntelliSpace PACS in Windows downgrade attack notice | Sep 20, 2024 | Same named componentWindows 11 (range 21H2 10.0.0)3 shared attributes: Imaging family, Named operating system, Operating System | No response from manufacturer |
| 2 | Philips IntelliSpace Cardiovascular and Xcelera servers allow privilege escalation through writable executable folders | Aug 14, 2018 | Same property (MITRE EMB3D)PID-23223 shared attributes: User accounts, Role-based access, Local Application | No response from manufacturer |
| 3 | Thermo Fisher Xcalibur and Foundation driver packages allow local privilege escalation | Jan 22, 2025 | Same platformWindows2 shared attributes: Named operating system, Local Application | No response from manufacturer |
| 4 | A low-privilege user can walk past role limits in Synapse Mobility | Aug 21, 2025 | 9 shared attributesImaging family, User accounts, Role-based access, Remote access +5 | No response from manufacturer |
| 5 | Philips lists more than 30 products in DejaBlue Remote Desktop advisory | Aug 15, 2019 | 10 shared attributesImaging family, Analysi, Image, Named operating system +6 | No response from manufacturer |
| 6 | Login credentials exposed on the workstation in a GE imaging viewer | Mar 16, 2026 | 8 shared attributesImaging family, Image, User accounts, Remote access +4 | No response from manufacturer |
| 7 | Philips IntelliSpace Portal 7.0 and 8.0 carry 35 vulnerabilities, led by remote code execution | Feb 27, 2018 | 9 shared attributesImaging family, Named operating system, Remote access, Device includes OS/kernel (PID-23) +5 | No response from manufacturer |
| 8 | Philips names PACS and imaging servers in Zerologon CVE-2020-1472 advisory | Sep 14, 2020 | 7 shared attributesImaging family, Analysi, Named operating system, User accounts +3 | No response from manufacturer |
| 9 | A legacy cardiology system, end-of-service since 2014, recalled for security | Jun 10, 2025 | 8 shared attributesUser accounts, Remote access, Role-based access, Named operating system +4 | No response from manufacturer |
| 10 | Carestream DirectView and ImageView systems affected by BlueKeep and DejaBlue RDP flaws | May 16, 2019 | 8 shared attributesImaging family, Named operating system, Remote access, Device includes OS/kernel (PID-23) +4 | No response from manufacturer |
| 11 | A dental imaging tool inherited a SYSTEM-level bug from an old SDK | Jul 17, 2025 | 7 shared attributesImaging family, Named operating system, User accounts, Role-based access +3 | No response from manufacturer |
| 12 | Canon Medical lists Windows 7 and 10 imaging systems as possibly affected by PrintNightmare | Aug 24, 2021 | 6 shared attributesImaging family, Named operating system, Device includes OS/kernel (PID-23), Operating System +2 | No response from manufacturer |
| 13 | Canon Medical lists Alphenix, CT TSX and MRT systems as affected by DejaBlue RDP flaws | Aug 20, 2019 | 6 shared attributesImaging family, Named operating system, Device includes OS/kernel (PID-23), Operating System +2 | No response from manufacturer |
| 14 | Philips FocalPoint before v2.2 exposed to Linux Copy Fail root escalation | May 4, 2026 | 5 shared attributesImaging family, Named operating system, User accounts, Device includes OS/kernel (PID-23) +1 | No response from manufacturer |
| 15 | BD Pyxis keeps access for expired Active Directory accounts when joined to a hospital domain | Sep 5, 2019 | 6 shared attributesUser accounts, Named operating system, Device includes OS/kernel (PID-23), Generic Application +2 | No response from manufacturer |
| 16 | Philips reviews 70 products for Windows RD Gateway and Remote Desktop Client flaws | Jan 15, 2020 | 7 shared attributesImaging family, Named operating system, Remote access, Operating System +3 | No response from manufacturer |
| 17 | Hologic validates MS17-010 WannaCry patch for Selenia, Dimensions and SecurView | Jul 25, 2017 | 5 shared attributesImaging family, Named operating system, Device includes OS/kernel (PID-23), Operating System +1 | No response from manufacturer |
| 18 | Siemens Healthineers lists imaging and lab products affected by DejaBlue Remote Desktop flaws | Sep 10, 2019 | 6 shared attributesImaging family, Named operating system, Remote access, Operating System +2 | No response from manufacturer |
| 19 | Carestream lists CR, Image Suite, DRX-Excel and OMNI systems as exposed to PrintNightmare | Jul 15, 2021 | 6 shared attributesImaging family, Named operating system, Device includes OS/kernel (PID-23), Operating System +2 | No response from manufacturer |
| 20 | Santesoft Sante DICOM Viewer Pro has two memory corruption flaws in DICOM parsing | Oct 12, 2023 | 5 shared attributesImaging family, Image, Named operating system, Generic Application +1 | No response from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-103 Microarchitectural Side Channels TID-116 Latent Privileged Access Port TID-202 Exploitable System Network Stack Component TID-204 Untrusted Programs Can Access Privileged OS Functions TID-205 Existing OS Tools Maliciously Used for Device Manipulation TID-210 Device Vulnerabilities Unpatchable TID-211 Device Allows Unauthenticated Firmware Installation TID-213 Faulty FW/SW Update Integrity Verification TID-215 Unencrypted SW/FW Updates TID-216 Firmware Update Rollbacks Allowed TID-219 OS/Kernel Privilege Escalation TID-222 Critical System Service May Be Disabled TID-224 Excessive Access via Software Diagnostic Features TID-226 Device leaks security information in logs TID-310 Remotely Accessible Unauthenticated Services TID-311 Default Credentials TID-316 Incorrect Certificate Verification Allows Authentication Bypass TID-324 HTTP Direct Object Reference TID-327 Out of Bounds Memory Access TID-329 Improper Password Storage TID-401 Undocumented Protocol Features TID-408 Unencrypted Sensitive Data Communication TID-411 Weak/Insecure Cryptographic Protocol
CWE weaknesses
CWE-1104 Use of Unmaintained Third Party Components CWE-1188 Insecure Default Initialization of Resource CWE-122 Heap-based Buffer Overflow CWE-125 Out-of-bounds Read CWE-1329 Reliance on Component That is Not Updateable CWE-200 Exposure of Sensitive Information to an Unauthorized Actor CWE-276 Incorrect Default Permissions CWE-284 Improper Access Control CWE-345 Insufficient Verification of Data Authenticity CWE-427 Uncontrolled Search Path Element CWE-494 Download of Code Without Integrity Check CWE-506 Embedded Malicious Code CWE-522 Insufficiently Protected Credentials CWE-639 Authorization Bypass Through User-Controlled Key CWE-787 Out-of-bounds Write CWE-912 Hidden Functionality