Aperio GT 450
Digital pathology slide scanner. Attributes come from Leica Biosystems's own public documentation for this product.
Attributes
Signals
Properties (MITRE EMB3D)
PID-31 Application-level software is present and running on the device PID-33 Device includes interactive applications, services, or user interfaces PID-332 Device includes authenticated services PID-41 Device exposes remote network services PID-411 Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations PID-4113 Device includes cryptographic functions for sensitive data, such as encryption or authentication
Attributes: component types
API Generic Application Generic Hardware Library Local Application Local Service Motor Sensor Modules User Interface
Attributes: interface types
Ethernet TCP
Attributes: assets
Calibration Data Credentials Sensor Data Software Configuration
Attributes: dataflows
Aperio GT 450 to Aperio iQC (whole slide images for artifact detection) Aperio GT 450 to LIS/LIMS/PACS via HL7 HistoCore SPECTRA CV Coverslipper to Aperio GT 450 (slide racks) SAM server to Aperio GT 450 scanners (remote setup and monitoring over network)
Matched threat intel
Top 20 of 44
Advisories in our coverage that share attributes with this product, strongest first: a named product or component, the same device type or lineage, then the most shared attributes. A shared attribute is a lead, not a finding. The status column shows only what Leica Biosystems has said.
| # | Advisory | Date | Shared | Leica Biosystems status |
|---|---|---|---|---|
| 1 | A hard-coded VNC password on a bioreactor, base score 9.8 | May 26, 2026 | Same property (MITRE EMB3D)PID-41114 shared attributes: Remote access, User accounts, Wired network, Closed-loop control +10 | No response from manufacturer |
| 2 | GE Healthcare imaging and ultrasound systems expose default service credentials | Dec 8, 2020 | Same property (MITRE EMB3D)PID-4119 shared attributes: Imaging family, Scanner, User accounts, Remote access +5 | No response from manufacturer |
| 3 | Baxter PrismaFlex and PrisMax send treatment data to EMR systems without encryption or authentication | Jun 18, 2020 | Same property (MITRE EMB3D)PID-4118 shared attributes: Hospital network, User accounts, Generic Application, Generic Hardware +4 | No response from manufacturer |
| 4 | Philips Interoperability Solution XDS can expose LDAP system credentials in cleartext | Jun 24, 2021 | Exposed to the same EMB3D threatTID-4117 shared attributes: User accounts, Hospital network, Wired network, Device exposes remote network services (PID-41) +3 | No response from manufacturer |
| 5 | Philips IntelliBridge EC40 and EC80 hubs allow weak SSH ciphers | Nov 14, 2019 | Same property (MITRE EMB3D)PID-41136 shared attributes: Remote access, Device exposes remote network services (PID-41), Device includes cryptographic functions for sensitive data, such as encryption or authentication (PID-4113), Local Service +2 | No response from manufacturer |
| 6 | Philips IntelliVue monitors and PIC iX skip certificate revocation and crash on bad input | Sep 10, 2020 | Same property (MITRE EMB3D)PID-41135 shared attributes: Hospital network, Wired network, Device includes cryptographic functions for sensitive data, such as encryption or authentication (PID-4113), Local Service +1 | No response from manufacturer |
| 7 | Santesoft Sante DICOM Viewer Pro 14.0.3 out-of-bounds read triggered by a malicious DICOM file | Feb 27, 2024 | Same signals3 shared attributes: Imaging family, DICOM or image parsing, Generic Application | No response from manufacturer |
| 8 | A bundled message broker shipped with guest:guest still enabled | May 29, 2026 | 15 shared attributesDigital, Pathology, Wired network, User accounts +11 | No response from manufacturer |
| 9 | Five flaws in Sante PACS Server, and one sends credentials in cleartext | Aug 12, 2025 | 14 shared attributesImaging family, HL7 or FHIR integration, User accounts, Wired network +10 | No response from manufacturer |
| 10 | An open-source DICOM server that shipped with auth off by default | Feb 6, 2025 | 12 shared attributesImaging family, Wired network, Remote access, User accounts +8 | No response from manufacturer |
| 11 | Missing authentication on a DNA sequencer control plane | Oct 21, 2025 | 12 shared attributesRemote access, User accounts, Hospital network, Device includes authenticated services (PID-332) +8 | No response from manufacturer |
| 12 | GE Healthcare imaging and PACS products ship with default or hard-coded passwords | Feb 6, 2018 | 10 shared attributesImaging family, Scanner, User accounts, Remote access +6 | No response from manufacturer |
| 13 | A .NET Remoting port left wide open on an imaging workstation | Apr 10, 2025 | 10 shared attributesImaging family, Wired network, Remote access, Hospital network +6 | No response from manufacturer |
| 14 | Orthanc DICOM Server Patches Integer Overflow That Corrupts Heap Memory | Sep 10, 2026 | 10 shared attributesImaging family, DICOM or image parsing, Remote access, User accounts +6 | No response from manufacturer |
| 15 | Stored passwords recoverable in a Siemens imaging platform | Feb 10, 2026 | 8 shared attributesImaging family, User accounts, Remote access, Hospital network +4 | No response from manufacturer |
| 16 | Philips Interventional Workspot can be shut down remotely through an OS command injection | Jan 19, 2021 | 9 shared attributesImaging family, Hospital network, Remote access, User accounts +5 | No response from manufacturer |
| 17 | Login credentials exposed on the workstation in a GE imaging viewer | Mar 16, 2026 | 8 shared attributesImaging family, User accounts, Hospital network, Remote access +4 | No response from manufacturer |
| 18 | Philips Vue PACS before 12.2.8.410 ships a default database password and can be overloaded | Jul 18, 2024 | 7 shared attributesImaging family, User accounts, DICOM or image parsing, Hospital network +3 | No response from manufacturer |
| 19 | Philips IntelliBridge EC 40 and EC 80 hubs carry hard-coded credentials and an unauthenticated path | Nov 18, 2021 | 7 shared attributesUser accounts, Hospital network, Device includes authenticated services (PID-332), Generic Hardware +3 | No response from manufacturer |
| 20 | Medtronic Valleylab FT10 and FX8 energy platforms ship hard-coded credentials and a vulnerable rssh | Nov 7, 2019 | 7 shared attributesUser accounts, Wired network, Local Service, Local Application +3 | No response from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-116 Latent Privileged Access Port TID-202 Exploitable System Network Stack Component TID-204 Untrusted Programs Can Access Privileged OS Functions TID-205 Existing OS Tools Maliciously Used for Device Manipulation TID-210 Device Vulnerabilities Unpatchable TID-219 OS/Kernel Privilege Escalation TID-221 Authentication Bypass By Message Replay TID-222 Critical System Service May Be Disabled TID-224 Excessive Access via Software Diagnostic Features TID-226 Device leaks security information in logs TID-303 Excessive Trust in Offboard Management/IDE Software TID-310 Remotely Accessible Unauthenticated Services TID-311 Default Credentials TID-313 Unauthenticated Session Changes Credential TID-316 Incorrect Certificate Verification Allows Authentication Bypass TID-317 Predictable Cryptographic Key TID-318 Insecure Cryptographic Implementation TID-319 Cross Site Scripting (XSS) TID-320 SQL Injection TID-323 Path Traversal TID-324 HTTP Direct Object Reference TID-326 Insecure Deserialization TID-327 Out of Bounds Memory Access TID-328 Hardcoded Credentials TID-329 Improper Password Storage TID-401 Undocumented Protocol Features TID-404 Remotely Triggerable Deadlock/DoS TID-405 Network Stack Resource Exhaustion TID-406 Unauthorized Messages or Connections TID-408 Unencrypted Sensitive Data Communication TID-411 Weak/Insecure Cryptographic Protocol
CWE weaknesses
CWE-1104 Use of Unmaintained Third Party Components CWE-1188 Insecure Default Initialization of Resource CWE-122 Heap-based Buffer Overflow CWE-125 Out-of-bounds Read CWE-1329 Reliance on Component That is Not Updateable CWE-1390 Weak Authentication CWE-1392 Use of Default Credentials CWE-1395 Dependency on Vulnerable Third-Party Component CWE-20 Improper Input Validation CWE-200 Exposure of Sensitive Information to an Unauthorized Actor CWE-276 Incorrect Default Permissions CWE-284 Improper Access Control CWE-287 Improper Authentication CWE-294 Authentication Bypass by Capture-replay CWE-306 Missing Authentication for Critical Function CWE-319 Cleartext Transmission of Sensitive Information CWE-321 Use of Hard-coded Cryptographic Key CWE-326 Inadequate Encryption Strength CWE-400 Uncontrolled Resource Consumption CWE-427 Uncontrolled Search Path Element CWE-476 NULL Pointer Dereference CWE-502 Deserialization of Untrusted Data CWE-506 Embedded Malicious Code CWE-522 Insufficiently Protected Credentials CWE-639 Authorization Bypass Through User-Controlled Key CWE-787 Out-of-bounds Write CWE-798 Use of Hard-coded Credentials CWE-912 Hidden Functionality CWE-916 Use of Password Hash With Insufficient Computational Effort