BaseSpace software
Sequencing data cloud analysis software. Attributes come from Illumina's own public documentation for this product.
Attributes
Signals
Properties (MITRE EMB3D)
PID-31 Application-level software is present and running on the device PID-311 Device includes the usage of a web/HTTP applications PID-33 Device includes interactive applications, services, or user interfaces PID-41 Device exposes remote network services PID-411 Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations PID-4113 Device includes cryptographic functions for sensitive data, such as encryption or authentication
Attributes: component types
API Cloud Application Generic Application Library Local Application Local Service Platform User Interface Web Application
Attributes: interface types
TCP
Attributes: assets
Report Data Sensor Data Telemetry Data User Data
Attributes: dataflows
BaseSpace to BioInsight Platform Core BaseSpace to DRAGEN (auto-launch at run completion) BaseSpace to Illumina Connected Insights via DRAGEN somatic analysis on BioInsight Platform Core BaseSpace to Illumina Connected Multiomics (RNA, protein, methylation data sets) BaseSpace to collaborators (governed data sharing) BaseSpace to customer downstream workflows via API DRAGEN to Emedgene (DRAGEN-called variants) Illumina sequencer to BaseSpace cloud (sequencing data, streamed in real time)
Matched threat intel
Top 20 of 77
Advisories in our coverage that share attributes with this product, strongest first: a named product or component, the same device type or lineage, then the most shared attributes. A shared attribute is a lead, not a finding. The status column shows only what Illumina has said.
| # | Advisory | Date | Shared | Illumina status |
|---|---|---|---|---|
| 1 | Missing authentication on a DNA sequencer control plane | Oct 21, 2025 | Same property (MITRE EMB3D)PID-41114 shared attributes: Lab and diagnostics family, Remote access, User accounts, Cloud connectivity +10 | No response from manufacturer |
| 2 | A 10.0 SQL injection on a patient health portal | Sep 5, 2024 | Same property (MITRE EMB3D)PID-31112 shared attributes: Patient or study database, Cloud connectivity, Web interface, User accounts +8 | No response from manufacturer |
| 3 | Unrestricted file upload on a PACS points straight at code execution | Apr 10, 2025 | Exposed to the same EMB3D threatTID-32311 shared attributes: File import, Patient or study database, Web interface, Remote access +7 | No response from manufacturer |
| 4 | Philips Tasy EMR and WebPortal carry cross-site scripting and information exposure flaws | Apr 30, 2019 | Same property (MITRE EMB3D)PID-3119 shared attributes: Web interface, User accounts, Device includes the usage of a web/HTTP applications (PID-311), Web Application +5 | No response from manufacturer |
| 5 | Unauthenticated SQL injection into an imaging database, base score 9.8 | Dec 6, 2024 | Exposed to the same EMB3D threatTID-32011 shared attributes: Patient or study database, Remote access, Web interface, User accounts +7 | No response from manufacturer |
| 6 | LifePoint Informatics Patient Portal generated lab report PDFs from a URL and a patient ID | Apr 5, 2022 | Same property (MITRE EMB3D)PID-3118 shared attributes: Lab and diagnostics family, Web interface, Cloud connectivity, Patient or study database +4 | No response from manufacturer |
| 7 | User enumeration on the CareLink Network, found at a conference | Dec 4, 2025 | Same property (MITRE EMB3D)PID-3118 shared attributes: Cloud connectivity, User accounts, Web interface, Remote access +4 | No response from manufacturer |
| 8 | Path traversal in Thermo Fisher's Torrent Suite lets authenticated users read server files | Oct 15, 2026 | Same property (MITRE EMB3D)PID-3119 shared attributes: Lab and diagnostics family, Sequenc, Device includes the usage of a web/HTTP applications (PID-311), Application-level software is present and running on the device (PID-31) +5 | No response from manufacturer |
| 9 | BeaconMedaes TotalAlert Scroll Medical Air Systems expose stored passwords to unauthenticated users | May 24, 2018 | Same property (MITRE EMB3D)PID-3115 shared attributes: User accounts, Web interface, Device includes the usage of a web/HTTP applications (PID-311), Web Application +1 | No response from manufacturer |
| 10 | Philips Tasy EMR HTML5 has two SQL injection flaws that expose patient data | Nov 4, 2021 | Same property (MITRE EMB3D)PID-3115 shared attributes: Patient or study database, User accounts, Web interface, Web Application +1 | No response from manufacturer |
| 11 | A hard-coded VNC password on a bioreactor, base score 9.8 | May 26, 2026 | Same property (MITRE EMB3D)PID-4118 shared attributes: Remote access, User accounts, Device exposes remote network services (PID-41), Device includes interactive applications, services, or user interfaces (PID-33) +4 | No response from manufacturer |
| 12 | Philips Clinical Collaboration Platform 12.2.1 and earlier has five web and authentication flaws | Sep 17, 2020 | Same property (MITRE EMB3D)PID-3114 shared attributes: Web interface, User accounts, Device includes the usage of a web/HTTP applications (PID-311), Web Application | No response from manufacturer |
| 13 | BD Alaris Infusion Central leaves a recoverable database password after installation | Feb 16, 2023 | Exposed to the same EMB3D threatTID-2215 shared attributes: Patient or study database, User accounts, Local Application, Platform +1 | No response from manufacturer |
| 14 | Change Healthcare PeerVue Web Server leaks technical details in HTTP error messages | Oct 4, 2018 | Same property (MITRE EMB3D)PID-3114 shared attributes: Web interface, Device includes the usage of a web/HTTP applications (PID-311), Web Application, TCP | No response from manufacturer |
| 15 | B. Braun SpaceStation with SpaceCom module has an open redirect in its web server | Mar 23, 2017 | Same property (MITRE EMB3D)PID-3114 shared attributes: Web interface, Device includes the usage of a web/HTTP applications (PID-311), Web Application, TCP | No response from manufacturer |
| 16 | Medtronic MyCareLink 24950 and 24952 monitors store upload credentials in a recoverable format | Aug 7, 2018 | Same property (MITRE EMB3D)PID-41133 shared attributes: Cloud connectivity, Device includes cryptographic functions for sensitive data, such as encryption or authentication (PID-4113), Telemetry Data | No response from manufacturer |
| 17 | GE Healthcare imaging and ultrasound systems expose default service credentials | Dec 8, 2020 | Same property (MITRE EMB3D)PID-4114 shared attributes: User accounts, Remote access, Generic Application, TCP | No response from manufacturer |
| 18 | Softneta MedDream PACS allows unauthenticated remote code execution | Sep 5, 2023 | Exposed to the same EMB3D threatTID-3243 shared attributes: User accounts, Web interface, Generic Application | No response from manufacturer |
| 19 | Cl0p lists Philips among nearly 50 victims of its PTC Windchill campaign | Aug 14, 2026 | 14 shared attributesCloud connectivity, Off-the-shelf software, User accounts, Remote access +10 | No response from manufacturer |
| 20 | Nine CVEs in Orthanc, and the image decoder is the soft spot | Apr 9, 2026 | 11 shared attributesFile import, Remote access, Patient or study database, Off-the-shelf software +7 | No response from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-202 Exploitable System Network Stack Component TID-204 Untrusted Programs Can Access Privileged OS Functions TID-205 Existing OS Tools Maliciously Used for Device Manipulation TID-210 Device Vulnerabilities Unpatchable TID-219 OS/Kernel Privilege Escalation TID-221 Authentication Bypass By Message Replay TID-222 Critical System Service May Be Disabled TID-225 Logs can be manipulated on the device TID-226 Device leaks security information in logs TID-301 Applications Binaries Modified TID-302 Install Untrusted Application TID-304 Manipulate Runtime Environment TID-305 Program Executes Dangerous System Calls TID-306 Sandboxed Environments Escaped TID-310 Remotely Accessible Unauthenticated Services TID-311 Default Credentials TID-313 Unauthenticated Session Changes Credential TID-315 Password Retrieval Mechanism Abused TID-316 Incorrect Certificate Verification Allows Authentication Bypass TID-317 Predictable Cryptographic Key TID-318 Insecure Cryptographic Implementation TID-319 Cross Site Scripting (XSS) TID-320 SQL Injection TID-323 Path Traversal TID-324 HTTP Direct Object Reference TID-326 Insecure Deserialization TID-327 Out of Bounds Memory Access TID-328 Hardcoded Credentials TID-329 Improper Password Storage TID-401 Undocumented Protocol Features TID-404 Remotely Triggerable Deadlock/DoS TID-405 Network Stack Resource Exhaustion TID-406 Unauthorized Messages or Connections TID-408 Unencrypted Sensitive Data Communication TID-411 Weak/Insecure Cryptographic Protocol
CWE weaknesses
CWE-1104 Use of Unmaintained Third Party Components CWE-1188 Insecure Default Initialization of Resource CWE-122 Heap-based Buffer Overflow CWE-125 Out-of-bounds Read CWE-1329 Reliance on Component That is Not Updateable CWE-1390 Weak Authentication CWE-1392 Use of Default Credentials CWE-1395 Dependency on Vulnerable Third-Party Component CWE-200 Exposure of Sensitive Information to an Unauthorized Actor CWE-22 Improper Limitation of a Pathname to a Restricted Directory CWE-276 Incorrect Default Permissions CWE-284 Improper Access Control CWE-287 Improper Authentication CWE-294 Authentication Bypass by Capture-replay CWE-306 Missing Authentication for Critical Function CWE-319 Cleartext Transmission of Sensitive Information CWE-321 Use of Hard-coded Cryptographic Key CWE-326 Inadequate Encryption Strength CWE-345 Insufficient Verification of Data Authenticity CWE-353 Missing Support for Integrity Check CWE-427 Uncontrolled Search Path Element CWE-434 Unrestricted Upload of File with Dangerous Type CWE-502 Deserialization of Untrusted Data CWE-522 Insufficiently Protected Credentials CWE-639 Authorization Bypass Through User-Controlled Key CWE-787 Out-of-bounds Write CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') CWE-798 Use of Hard-coded Credentials CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') CWE-916 Use of Password Hash With Insufficient Computational Effort